AS 1684.3-2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Residential timber-framed construction Cyclonic areas
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
19-07-2024
21-06-2010
Provides the building industry with procedures that can be used to determine building practice, to design or check construction details, and to determine member sizes, and bracing and fixing requirements for timber-framed construction in cyclonic areas.
Committee |
TM-002
|
DevelopmentNote |
Under Revision by DR AS 1684.3:2020.
|
DocumentType |
Standard
|
ISBN |
978 0 7337 9434 6
|
Pages |
263
|
ProductNote |
The CD included with this product is intended to be used on Microsoft PC environments.
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard specifies requirements for building practice and the selection, placement and fixing of the various structural elements used in the construction of timber-framed Class 1 and Class 10 buildings as defined by the Building Code of Australia and within the limitations given in Clause 1.4. The provisions of this Standard also apply to alterations and additions to such buildings.This Standard also provides building practice and procedures that assist in the correct specification and determination of timber members, bracing and connections, thereby minimizing the risk of creating an environment that may adversely affect the ultimate performance of the structure.This Standard may also be applicable to the design and construction of other classes of buildings where the design criteria, loadings and other parameters applicable to those classes of building are within the limitations of this Standard.NOTES:1 See AS 1684.1 for details of design criteria, loadings and other parameters.2 Whilst this Standard may be used to design Class 10 buildings, less conservative levels of design for this building class may be permitted by building regulations and other Australian Standards.3 Advisory information for the construction and specifications of timber stairs, handrails and balustrades is provided in the FWPA’s publication (see the Bibliography).
First published as AS O56-1946.
Second edition 1948.
Revised and redesignated as AS CA38-1971.
Revised and redesignated as AS 1684-1975.
Third edition 1992.
Revised and redesignated in part as AS 1684.3-1999.
Third edition 2010.
Reissued incorporating Amendment No. 1 (June 2012).
AS/NZS 1859.4:2004 | Reconstituted wood-based panels - Specifications Wet-processed fibreboard |
AS 1691-1985 | Domestic oil-fired appliances - Installation |
AS 2796.1-1999 | Timber - Hardwood - Sawn and milled products Product specification (Reconfirmed 2016) |
AS 3700-2001 | Masonry structures |
AS 1860.2-2006 | Particleboard flooring Installation (Reconfirmed 2016) |
AS/NZS 1604.4:2004 | Specification for preservative treatment Laminated veneer lumber (LVL) |
AS 4440-2004 | Installation of nailplated timber roof trusses |
AS/NZS 1604.5:2005 | Specification for preservative treatment Glued laminated timber products |
AS 2870-1996 | Residential slabs and footings - Construction |
AS 1684.1-1999 | Residential timber-framed construction Design criteria |
ISO/TR 12910:2010 | Light-frame timber construction Comparison of four national design documents |
AS/NZS 2918:2001 | Domestic solid fuel burning appliances - Installation |
AS 4055-2006 | Wind loads for housing |
AS 1684.2-2010 | Residential timber-framed construction Non-cyclonic areas |
AS 5604-2005 | Timber - Natural durability ratings (Reconfirmed 2016) |
AS 1170.4-2007 | Structural design actions Earthquake actions in Australia (Reconfirmed 2018) |
AS 1810-1995 | Timber - Seasoned cypress pine - Milled products |
AS/NZS 4534:2006 | Zinc and zinc/aluminium-alloy coatings on steel wire (Reconfirmed 2017) |
AS 1684.4-2010 | Residential timber-framed construction Simplified - Non-Cyclonic Areas |
AS/NZS 1860.1:2002 | Particleboard flooring Specifications |
AS 3600 SUPP 1-1994 | Concrete structures - Commentary (Supplement to AS 3600-1994) |
AS 2870 SUPP 1-1996 | Residential slabs and footings - Construction - Commentary (Supplement to AS 2870-1996) |
AS 1214-1983 | Hot-dip galvanized coatings on threaded fasteners (ISO metric coarse thread series) |
AS 4785.1-2002 | Timber - Softwood - Sawn and milled products Product specification (Reconfirmed 2016) |
AS 1397-2001 | Steel sheet and strip - Hot-dipped zinc-coated or aluminium/zinc-coated |
AS/NZS 1604.3:2004 | Specification for preservative treatment Plywood |
AS 1720.2-2006 | Timber structures Timber properties |
AS 1170.4 SUPP 1-1993 | Minimum design loads on structures (known as the SAA Loading Code) Earthquake loads - Commentary (Supplement to AS 1170.4-1993) |
AS/NZS 2878:2000 | Timber - Classification into strength groups |
AS/NZS 1170.1:2002 | Structural design actions Permanent, imposed and other actions |
AS/NZS 1604.2:2004 | Specification for preservative treatment Reconstituted wood-based products |
AS 3700 SUPP 1-2004 | Masonry structures - Commentary (Supplement to AS 3700-2001) |
AS/NZS 1170.2:2002 | Structural design actions Wind actions |
AS/NZS 2269.0:2008 | Plywood - Structural Specifications |
AS/NZS 1148:2001 | Timber - Nomenclature - Australian, New Zealand and imported species (Reconfirmed 2016) |
AS 1720.1-1997 | Timber structures Design methods |
AS 3600-2009 | Concrete structures |
AS/NZS 4791:2006 | Hot-dip galvanized (zinc) coatings on ferrous open sections, applied by an in-line process (Reconfirmed 2017) |
AS 1684.4-2010 | Residential timber-framed construction Simplified - Non-Cyclonic Areas |
AS 4654.2-2012 | Waterproofing membranes for external above-ground use Design and installation |
AS 1684.2-2010 | Residential timber-framed construction Non-cyclonic areas |
AS/NZS 1748.1:2011 | Timber - Solid - Stress-graded for structural purposes General requirements |
AS 2870-2011 | Residential slabs and footings |
AS 2455.1:2019 | Textile floor coverings - Installation practice General |
AS 4773.2-2010 | Masonry in small buildings - Construction |
AS 3740-2010 | Waterproofing of domestic wet areas |
AS 4773.1-2010 | Masonry in small buildings Design |
WS11-2012 | Timber-framed Systems for External Noise |
AS 4809:2017 | Copper pipe and fittings - Installation and commissioning |
AS 1884-2012 | Floor coverings - Resilient sheet and tiles - Installation practices |
AS 3818.8-2010 | Timber - Heavy structural products - Visually graded Stumps and sole plates |
AS/NZS 2589:2017 | Gypsum linings - Application and finishing |
AS 2455.2:2019 | Textile floor coverings - Installation practice Carpet tiles |
AS 2050:2018 | Installation of Roof Tiles |
AS 1720.3:2016 | Timber structures Design criteria for timber-framed residential buildings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.