AS 4825-2011
Current
The latest, up-to-date edition.
Tunnel fire safety
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
01-02-2011
Provides a generic framework for establishing the fire safety systems that are required in new road, rail or bus tunnels to provide an acceptable level of safety in case of fire; provides guidance in the development of a fire safety strategy, the design and documentation of fire safety systems for tunnels.
Committee |
FP-023
|
DocumentType |
Standard
|
ISBN |
978 0 7337 9757 6
|
Pages |
75
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard provides guidelines for fire safety in new road, rail and bus tunnels. It covers uni-directional and bi-directional tunnels of various lengths meeting the limitations outlined in Clause 1.3.This Standard can be applied to tunnels involving vehicles with no drivers such as driverless trains, although special additional considerations may apply. For rail and bus tunnels, this Standard addresses the tunnel/station interface. This Standard addresses tunnels used to carry both passengers and freight, and the combustible materials and goods carried by those vehicles.This Standard is not specifically intended for existing tunnels; however, the general principles may be applied to the upgrade of existing tunnels to improve fire safety. In the case of modification works to a tunnel, the modification should be treated as building a new tunnel for interpretation of this Standard. The existing constraints however, may limit the choice of fire safety measures that can be implemented. Such constraints may result in the fire safety measures not being able to fully satisfy the objective contained in this Standard.
First published as AS 4825-2011.
AS/NZS ISO 31000:2009 | Risk management - Principles and guidelines |
AS 7240.10-2007 | Fire detection and alarm systems Point-type flame detectors |
AS 2118.10-1995 | Automatic fire sprinkler systems Approval documentation (Reconfirmed 2013) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 2419.1-2005 | Fire hydrant installations System design, installation and commissioning |
AS 2441-2005 | Installation of fire hose reels (Reconfirmed 2018) |
AS 3600 SUPP 1-1994 | Concrete structures - Commentary (Supplement to AS 3600-1994) |
AS/NZS 1170.1:2002 | Structural design actions Permanent, imposed and other actions |
AS 1603.7-1996 | Automatic fire detection and alarm systems Optical beam smoke detectors (Reconfirmed 2016) |
AS 1670.4-2004 | Fire detection, warning, control and intercom systems - System design, installation and commissioning Sound systems and intercom systems for emergency purposes |
AS 3745-2010 | Planning for emergencies in facilities |
AS 2118.3-2010 | Automatic fire sprinkler systems Deluge systems |
AS 2293.1-2005 | Emergency escape lighting and exit signs for buildings System design, installation and operation |
AS 2118.1-2006 | Automatic fire sprinkler systems General systems |
AS 4587-1999 | Water mist fire protection systems - System design, installation and commissioning |
AS 1603.8-1996 | Automatic fire detection and alarm systems Multi-point aspirated smoke detectors (Reconfirmed 2016) |
AS 1670.1-2004 | Fire detection, warning, control and intercom systems - System design, installation and commissioning Fire |
AS 2484.2-1991 | Fire - Glossary of terms Fire protection and firefighting equipment |
AS 2484.1-1990 | Fire - Glossary of terms Fire tests (Reconfirmed 2016) |
AS 1851-2005 | Maintenance of Fire Protection Systems and Equipment |
AS 2444-2001 | Portable fire extinguishers and fire blankets - Selection and location (Reconfirmed 2021) |
AS 4118.2.1-1995 | Fire sprinkler systems Piping - General (Reconfirmed 2013) |
AS 1603.5-1996 | Automatic fire detection and alarm systems Manual call points (Reconfirmed 2016) |
AS 1530.4-2005 | Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction |
AS 2118.1-1999 | Automatic fire sprinkler systems General requirements |
AS 1905.1-2005 | Components for the protection of openings in fire-resistant walls Fire-resistant doorsets |
AS 4391-1999 | Smoke management systems - Hot smoke test (Reconfirmed 2016) |
AS/NZS 1668.1:1998 | The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings |