AS/NZS 3002:2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical installations - Shows and carnivals
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
26-06-2021
English
01-01-2002
Specifies requirements, in addition to those of AS/NZS 3000, for electrical installations for the supply of electricity to, and for temporary wiring within, concessions, tents and other temporary structures used for entertainment or display and purposes associated with shows and carnivals. Also applies to the supply of electricity to distributed temporary installations such as tent cities set up for scout jamborees, army camps and similar events.
Committee |
EL-001
|
DocumentType |
Standard
|
ISBN |
0 7337 4724 8
|
Pages |
20
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard sets out requirements for the supply of electricity at low-voltage to, and for temporary wiring within, concessions, tents, living quarters and other temporary structures used for entertainment or display and purposes associated therewith in shows, carnivals and in temporary low-voltage electrical installations such as those installed in temporary tent cities used for scouting jamborees, army camps and similar events. It also makes recommendations for the in-service testing of portable and fixed electrical equipment used on such sites.NOTES: 1 For the purpose of this Standard, a low-voltage electrical installation which is intended to be connected to a permanent source of low-voltage electrical power supply for a period of not more than 4 weeks shall be deemed to be a temporary site low-voltage electrical installation.2 Recommendations regarding testing are set out in Appendix A.This Standard does not apply to fixed wiring within low-voltage electrical installations used in shows, carnivals and other similar events.
First published as AS 3002-1974.
Second edition 1985.
Jointly revised and designated as AS/NZS 3002:2002.
AS 1939-1990 | Degrees of protection provided by enclosures for electrical equipment (IP Code) |
AS/NZS 60598.2.8:2002 | Luminaires Particular requirements - Handlamps (IEC 60598-2-8:2001, MOD) |
AS/NZS 3108:1994 | Approval and test specification - Particular requirements for isolating transformers and safety isolating transformers |
AS 3439.4-1995 | Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS) |
AS/NZS 3190:2002 | Approval and test specification - Residual current devices (current-operated earth-leakage devices) |
AS 3533.2-1997 | Amusement rides and devices Operation and maintenance |
AS/NZS 3760:2001 | In-service safety inspection and testing of electrical equipment |
AS/NZS 3112:2004 | Approval and test specification - Plugs and socket-outlets |
AS/NZS 3112:2000 | Approval and test specification - Plugs and socket-outlets |
AS 3533.1-1997 | Amusement rides and devices Design and construction |
AS/NZS 3100:2002 | Approval and test specification - General requirements for electrical equipment |
AS/NZS 3123:2005 | Approval and test specification - Plugs, socket-outlets and couplers for general industrial application (Reconfirmed 2016) |
AS/NZS 3120:1999 | Approval and test specification - Cord extension sockets |
AS 2790-1989 | Electricity generating sets - Transportable (Up to 25 kW) |
AS 3533-1988 | Amusement rides and devices |
AS/NZS 3123:2000 | Approval and test specification - Plugs, socket-outlets and couplers for general industrial application |
AS/NZS 3109.1:1996 | |
AS/NZS 3760:2003 | In-service safety inspection and testing of electrical equipment |
AS/NZS 3012:2003 | Electrical installations - Construction and demolition sites |
AS 3190-1994 | Approval and test specification - Residual current devices (current-operated earth-leakage devices) |
AS/NZS 60598.2.8:1998 | Luminaires Particular requirements - Handlamps |
AS/NZS 3105:2007 | Approval and test specification - Electrical portable outlet devices |
AS/NZS 3152:1992 | Approval and test specification - Decorative lighting outfits |
AS/NZS 3128:1998 | Approval and test specification - Portable lamp standards and brackets |
AS 3010.1-1987 | Electrical installations - Supply by generating set Internal combustion engine driven sets |
AS/NZS 3012:1995 | Electrical installations - Construction and demolition sites |
AS/NZS 3105:1998 | Approval and test specification - Electrical portable outlet devices |
AS/NZS 3000:2000 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 3860-1991 | Fixed guideway people movers |
AS/NZS 3001:2001 | Electrical installations - Relocatable premises (including caravans and tents) and their site installations |
AS/NZS 3760:2003 | In-service safety inspection and testing of electrical equipment |
AS/NZS 3019:2007 | Electrical installations - Periodic verification |
AS 3533.3-2003 | Amusement rides and devices In-service inspection (Reconfirmed 2013) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.