AS/NZS 3013:2005
Current
The latest, up-to-date edition.
Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
22-08-2005
Sets out a classification scheme for wiring systems according to their resistance to the hazards of fire and mechanical damage. Type tests to verify the level of protection provided by a wiring system are given. Intended for reference in other Standards which specify wiring systems with a degree of resistance to damage from fire or mechanical impact.
Committee |
EL-037
|
DocumentType |
Standard
|
ISBN |
0 7337 6828 8
|
Pages |
40
|
ProductNote |
Reconfirmed 14/08/2020.
This standard has been reconfirmed in Australia in 2020 and remains current in New Zealand. Reconfirmation Notice 14/08/2020 |
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard sets out a classification system for wiring system elements. The classification is according to the wiring system’s ability to—a) maintain circuit integrity under fire conditions for a specified period; andb) maintain circuit integrity against mechanical damage of specified severity.It specifies type tests to classify the performance of the various types of wiring system elements.If an assembled wiring system is tested to this Standard, the classification achieved cannot be assigned to any one of its individual elements. The wiring system classification achieved shall only be applicable to the assembled wiring system as tested.This Standard does not address the screening function of screened cables after exposure to fire conditions.Note: Elements of a wiring system might need replacement after exposure to fire conditions or mechanical damage.
Originated as AS3013-1990.
Previous edition AS/NZS3013:1995.
Third edition 2005.
AS/NZS 3000:2000 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 2053.1:2001 | Conduits and fittings for electrical installations General requirements (Reconfirmed 2016) |
AS/NZS 2053.6:2001 | Conduits and fittings for electrical installations Profile-wall, smooth-bore conduits and fittings of insulating material (Reconfirmed 2016) |
AS/NZS 2053.4:1995 | Conduits and fittings for electrical installations Flexible plain conduits and fittings of insulating material (Reconfirmed 2016) |
AS 1530.4-1997 | Methods for fire tests on building materials, components and structures Fire-resistance tests of elements of building construction |
AS/NZS 5000.1:2003 | Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV |
AS 1074-1989 | Steel tubes and tubulars for ordinary service (Reconfirmed 2018) |
AS 2053-1984 | Non-metallic conduits and fittings |
AS/NZS 2053.3:1995 | Conduits and fittings for electrical installations Rigid plain conduits and fittings of fibre-reinforced concrete material (Reconfirmed 2016) |
AS/NZS 2053.2:2001 | Conduits and fittings for electrical installations Rigid plain conduits and fittings of insulating material (Reconfirmed 2016) |
AS 1530.4-2005 | Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction |
AS/NZS 2053.5:2001 | Conduits and fittings for electrical installations Corrugated conduits and fittings of insulating material (Reconfirmed 2016) |
AS/NZS 3808:2000 | Insulating and sheathing materials for electric cables (Reconfirmed 2017) |
AS/NZS 2053.8:1995 | Conduits and fittings for electrical installations Flexible conduits and fittings of metal or composite material (Reconfirmed 2016) |
AS/NZS 1125:2001 | Conductors in insulated electric cables and flexible cords (Reconfirmed 2017) |
AS/NZS 2053.7:2002 | Conduits and fittings for electrical installations Rigid metal conduits and fittings (Reconfirmed 2016) |
AS/NZS 3187:1995 | Approval and test specification - Mineral-insulated metal-sheathed cables |
AS/NZS 5000.1:2005 | Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017) |
AS 2118.5-1995 | Automatic fire sprinkler systems - Domestic |
AS/NZS 4507:2006 | Cables - Classification of characteristics when exposed to fire |
AS 2118.1:2017 | Automatic fire sprinkler systems General systems |
AS 4118.1.4-1994 | Fire sprinkler systems Components - Valve monitors (Reconfirmed 2013) |
AS/NZS 1680.2.4:1997 | Interior lighting Industrial tasks and processes |
AS 1530.4-2005 | Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction |
AS 2941-2002 | Fixed fire protection installations - Pumpset systems |
AS/NZS 1668.1:1998 | The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings |
AS/NZS 3009:1998 | Electrical installations - Emergency power supplies in hospitals |
AS 2941-2008 | Fixed fire protection installations - Pumpset systems |
AS 2118.6-1995 | Automatic fire sprinkler systems - Combined sprinkler and hydrant |
AS 2118.4-2012 | Automatic fire sprinkler systems Sprinkler protection for accommodation buildings not exceeding four storeys in height |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 2067-2008 | Substations and high voltage installations exceeding 1 kV a.c. |
AS 2941-2013 | Fixed fire protection installations - Pumpset systems |
AS 1735.2-2001 | Lifts, escalators and moving walks Passenger and goods lifts - Electric |
AS 2118.2-1995 | Automatic fire sprinkler systems - Wall wetting sprinklers (Drenchers) |
AS 2293.1-2005 | Emergency escape lighting and exit signs for buildings System design, installation and operation |
AS 1670.5:2016 | Fire detection, warning, control and intercom systems - System design, installation and commissioning Special hazards systems |
AS 2118.6-2012 | Automatic fire sprinkler systems Combined sprinkler and hydrant systems in multistorey buildings |
AS 2118.4-1995 | Automatic fire sprinkler systems - Residential |
AS 4214:2018 | Gaseous fire-extinguishing systems |
AS 2067:2016 | Substations and high voltage installations exceeding 1 kV a.c. |
AS 3772-2008 | Pre-engineered fire protection systems for cooking equipment |
AS/NZS 1680.2.4:2017 | Interior and workplace lighting Industrial tasks and processes |
AS 2118.1-2006 | Automatic fire sprinkler systems General systems |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 4487-2013 | Condensed aerosol fire extinguishing systems - Requirements for system design, installation and commissioning and test methods for components |
AS/NZS 2293.1:2018 | Emergency lighting and exit signs for buildings System design, installation and operation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.