• Shopping Cart
    There are no items in your cart

AS/NZS 3260:1993

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Approval and test specification - Safety of information technology equipment including electrical business equipment

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

29-05-2024

Superseded by

AS/NZS 60950:2000

Language(s)

English

Published date

01-01-1993

€154.77
Excluding VAT

1 - AS/NZS 3260:1993 APPROVAL AND TEST SPECIFICATION-SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQU
4 - PREFACE
8 - CONTENTS
18 - FOREWORD
20 - INTRODUCTION
23 - 1 General
23 - 1.1 Scope
23 - 1.1.1 Equi pment covered by thi s standard
25 - 1.1.2 Additional requirements
25 - 1.1.3 Exclusions
26 - 1.2 Definitions
27 - 1.2.1 Equipment electrical ratings
27 - 1.2.2 Operating conditions
28 - 1.2.3 Equipment mobility
28 - 1.2.4 Classes of equipment - Protection against electric shock
29 - 1.2.5 Connection to the supply
29 - 1.2.6 Enclosures
30 - 1.2.7 Accessi bi li ty
30 - 1.2.8 Circuit and circuit characteristics
32 - 1.2.9 Insulation
33 - 1.2.10 Creepage distances and clearances
33 - 1.2.11 Components
34 - 1.2.12 Power di stri buti on
37 - 1.2.13 Flammability
38 - 1.2.14 Miscellaneous
40 - 1.3 General requirements
40 - 1.3.1 Equi pment design and constructi on
40 - 1.3.2 User information
40 - 1.3.3 Classification of equipment
40 - 1.4 General conditions for tests
44 - 1.5 Components
44 - 1.5.1 General
44 - 1.5.2 Evaluation and testing of components
45 - 1.5.3 Transformers
45 - 1.5.4 High voltage components
45 - 1.5.5 Interconnecting cables
45 - 1.5.6 Mains capacitors
45 - 1.6 Power i nterface
45 - 1.6.1 Input current
46 - 1.6.2 Voltage limit of hand-held equipment
46 - 1.6.3 Neutral conductor
46 - 1.6.4 Components in equipment for IT power systems
46 - 1.6.5 Mains supply tolerance
46 - 1.7 Marking and instructions
46 - 1.7.1 Power rating
49 - 1.7.2 Safety instructions
49 - 1.7.3 Short duty cycles
50 - 1.7.4 Mains voltage adjustment
50 - 1.7.5 Power outlets
50 - 1.7.6 Fuses
50 - 1.7.7 Wiring terminals
51 - 1.7.8 Controls and indicators
53 - 1.7.9 Isolation of multiple power sources
53 - 1.7.10 IT power systems
53 - 1.7.11 Protection in building installation
53 - 1.7.12 High leakage current
53 - 1.7.13 Thermostats and other regulating devices
53 - 1.7.14 Language
53 - 1.7.15 Durability
54 - 1.7.16 Removable parts
54 - 1.7.17 Lithium batteries
54 - 1.7.18 Operator access with a tool
54 - 1.7.19 Equipment for restricted access locations
55 - 2 Protection from hazards
55 - 2.1 Protection from electric shock and energy hazards
55 - 2.1.1 Access to energized parts
55 - 2.1.2 Protection in operator access areas
56 - 2.1.3 Access to internal wiring
58 - 2.1.4 Protection in service access areas and restricted access locations
58 - 2.1.5 Energy hazards in operator access areas
59 - 2.1.6 Clearances behind conductive enclosures
59 - 2.1.7 Shafts of manual controls
59 - 2.1.8 Isolation of manual controls
60 - 2.1.9
60 - 2.1.10
60 - 2.2 Insulation
60 - 2.2.1 Methods for insulation
60 - 2.2.2 Properties of insulating materials
61 - 2.2.3 Humidity conditioning
61 - 2.2.4 Requirements for insulation
61 - 2.2.5 Insulation parameters
61 - 2.2.6 Categories of insulation
65 - 2.2.7 Determination of working voltage
66 - 2.2.8 Double or reinforced insulation bridged by components
67 - 2.3 SELV circuits
67 - 2.3.1 General requirements
67 - 2.3.2 Voltages under normal conditions
67 - 2.3.3 Voltages under fault conditions
69 - 2.3.4 Additional constructional requirements
70 - 2.3.5 Connection of SELV circuits to other circuits
71 - 2.4 Limited current circuits
72 - 2.5 Provisions for earthing
75 - 2.6 Disconnection from pri mary power
75 - 2.6.1 General requirement
75 - 2.6.2 Disconnect devices
76 - 2.6.3 Permanently connected equipment
76 - 2.6.4 Parts of a disconnect device which remain energized
76 - 2.6.5 Switches in flexible cords
77 - 2.6.6 Single-phase equipment
77 - 2.6.7 Three-phase equipment
78 - 2.6.8 Switches as disconnect devices
78 - 2.6.9 Plugs as disconnect devices
78 - 2.6.10 Deleted - reserved for future use.
78 - 2.6.11 Interconnected equipment
78 - 2.6.12 Mult ipl e power sources
78 - 2.6.13 Deleted - reserved for future use.
79 - 2.7 Overcurrent and earth fault protection in primary circuits
79 - 2.7.1 Basic requirements
79 - 2.7.2 Faults not covered in 5.4
79 - 2.7.3 Short-circuit backup protection
80 - 2.7.4 Number and location of protective devices
82 - 2.7.5 Protection by several devices
82 - 2.7.6 Warning to service personnel
82 - 2.8 Safety interlocks
86 - 2.9 Clearances, creepage distances and distances through insulation
86 - 2.9.1 General
88 - 2.9.2 Clearances
93 - 2.9.3 Creepage distances
94 - 2.9.4 Solid insulation
97 - 2.9.5 Coated printed boards
101 - 2.9.6 Enclosed and sealed parts
102 - 2.9.7 Spacings filled by insulating compound
103 - 2.9.8 Component external terminations
103 - 2.9.9 Insulation with varying dimensions
104 - 2.10 Interconnection of equipment
104 - 2.10.1 General requirements
104 - 2.10.2 Types of interconnection circuits
104 - 2.10.3 ELV circuit s as interconnection circuits
105 - 2.11 Limited power source
107 - 3 Wiring, connections and supply
107 - 3.1 General
109 - 3.2 Connection to primary power
116 - 3.3 Wiring terminals for external primary power supply conductors
120 - 4 Physical requirements
120 - 4.1 Stability and mechanical hazards
122 - 4.2 Mechanical strength and stress relief
122 - 4.2.1 General
122 - 4.2.2 Steady force test, 30 N
122 - 4.2.3 Steady force test, 250 N
122 - 4.2.4 Steel ball test
123 - 4.2.5 Drop test
125 - 4.2.6 Stress relief test
125 - 4.2.7 Compliance criteria
125 - 4.2.8 Mechanical strength of cathode ray tubes
125 - 4.3 Construction details
134 - 4.4 Resistance to fire
134 - 4.4.1 Methods of achieving resistance to fire
134 - 4.4.2 Minimizing the risk of ignition
134 - 4.4.3 Flammability of materials and components
136 - 4.4.4 Materials for enclosures and for decorative parts
137 - 4.4.5 Conditions for fire enclosures
139 - 4.4.6 Fire enclosure construction
141 - 4.4.7 Doors or covers in fire enclosures
141 - 4.4.8 Flammable liquids
143 - 5 Thermal and electrical requirements
143 - 5.1 Heating
145 - 5.2 Earth leakage current
145 - 5.2.1 General
145 - 5.2.2 Requirements
146 - 5.2.3 Single-phase equipment
147 - 5.2.4 Three-phase equipment
148 - 5.2.5 Equipment with earth leakage current exceeding 3,5 mA
148 - 5.3 Electri c strength
148 - 5.3.1 General
149 - 5.3.2 Test procedure
152 - 5.4 Abnormal operating and fault conditions
157 - 6 Connection to telecommunication networks
157 - 6.1 General
157 - 6.2 TNV circuits
157 - 6.2.1 TNV circuit characteristics and requirements
163 - 6.2.2 Protection against contact with TNV circuits
165 - 6.3 Protection of telecommunication network service personnel, and users of other equipment connected to the network,...
165 - 6.3.1 Protection from hazardous voltages
165 - 6.3.2 Use of protective earthing
165 - 6.3.3 Separationof the telecommunication network from earth
168 - 6.3.4 Leakage currents to and from telecommunication networks
170 - 6.4 Protection of the equipment users from overvoltages on the telecommunication networks
170 - 6.4.1 Separation requirements
170 - 6.4.2 Test procedure
173 - 6.5 Protection of the telecommunication wiring system from overheating
176 - Annex A - Tests for resistance to heat and fire
176 - A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary...
177 - A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for materials...
179 - A.3 High current arcing ignition test (see 4.4.4)
180 - A.4 Hot wire ignition test (see 4.4.4)
181 - A.5 Hot flaming oi l test (see 4.4.6)
181 - A.6 Flammability tests for classifying materials V-0, V-1 or V-2 (see 1.5.4 and 4.4)
183 - A.7 Flammability test for classifying foamed materials HF-1, HF-2 or HBF (see 1.5.4, 4.4.1 and 4.4.3)
185 - A.8 Flammability test for classifying materials HB (see 4.4.3 and 4.4.4)
186 - A.9 Flammability test for classifying materials 5V (see 4.4.1)
190 - Annex B - Motor tests under abnormal conditions (see 4.4.5.2 and 5.4.2)
190 - B.1 General requirements
190 - B.2 Test conditions
191 - B.3 Maximum temperatures
192 - B.4 Running overload test
192 - B.5 Locked-rotor overload test
193 - B.6 Running overload test for d.c. motors in secondary circuits
194 - B.7 Locked-rotor overload test for d.c. motors in secondary circuits
194 - B.8 Test for motors with capacitors
195 - B.9 Test for three-phase motors
195 - B.10 Test for series motors
196 - Annex C - Transformers (see 1.5.3)
196 - C.1 Overload test
198 - C.2 Insulation
202 - Annex D - Measuring instrument for earth leakage current tests (See 5.2.2 and Annex G.2)
203 - Annex E - Temperature rise of a winding (see 1.4.8 and 5.1)
204 - Annex F - Measurement of creepage distances and clearances (see 2.9)
212 - Annex G - Earth leakage current for equipment intended to be connected directly to IT power systems (see 5.2)
212 - G.1 General
212 - G.2 Requirements
213 - G.3 Single-phase equipment
214 - G.4 Three-phase equipment
215 - G. 5 Equipment with earth leakage current exceeding 3,5 mA
216 - Annex H - Ionizing radiation (see 4.3.12)
217 - Annex J - Table of electrochemical potentials (see 2.5.10)
218 - Annex K - Thermal controls (see 1.5.2 and 5.4.8)
220 - Annex L - Normal load conditions for some types of electrical business equipment (see 1.2.2.1 and 5.1)
221 - Annex M - Criteria for telephone ringing signals (see 6.2.1.1)
221 - M.1 Introduction
221 - M.2 Method A
224 - M.3 Method B
226 - Annex N - Impulse test generator (see 2.9.9 and 6.4.2.1)
227 - Annex P - Normative references
229 - Annex Q - Bibliography
230 - Annex R - Example of requirements for a quality control programme
230 - R.1 Minimum separation distances for unpopulated coated printed boards (see 2.9.5)
232 - R.2 Reduced clearances (see 2.9.2)
234 - Annex S - Procedure for impulse testing (see 6.4.2.3)
234 - S.1 Test equi pment
234 - S.2 Test procedure
234 - S.3 Examples of waveforms during impulse testing
236 - Annex T - Guidance on protection against ingress of water (see 1.1.2)
238 - Annex U - Insulated winding wires for use without interleaved insulation (see 2.9.4.4)
238 - U.1 Wire construction
238 - U.2 Type tests
239 - U.3 Routine test
240 - Annex V - Change to the definitions of SELV circuit and TNV circuit
242 - APPENDIX 1 - VARIATIONS FOR AUSTRALIA AND NEW ZEALAND
244 - APPENDIX 2 - ALTERNATIVE RESISTANCE TO FIRE TEST DETERMINATION OF IGNITABILITY AND COMBUSTION PROPAGATION
246 - APPENDIX 3 - D.C. COMPONENT FROM A.C. EQUIPMENT

Specifies the safety requirements for information technology equipment, including electrical business equipment, computers and equipment connected to telecommunications networks.

Committee
TE-001
DocumentType
Standard
ISBN
0 7262 8020 8
Pages
221
ProductNote
(In Rul ES/1)
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Equipment covered by this standardThis standard is applicable to mains-powered or battery-powered information technology equipment, including electrical business equipment and associated equipment, with a RATED VOLTAGE not exceeding 600 V.This standard is also applicableto such equipment designedand intendedto be connected directly to a TELECOMMUNICATION NETWORK and forming part of a subscriber's installation, regardless of ownership and of responsibility for installation and maintenance, and regardless of the source of power.This standard specifies requirements intendedto ensure safety for the OPERATOR and layman who may come into contact with the equipment and, where specifically stated, for SERVICE PERSONNEL.This standard is intended to ensure the safety of installed equipment, whether it consists of a system of interconnected units or independent units, subject to installing, operating and maintaining the equipment in the manner prescribed by the manufacturer.Examples of equipment which is within the scope of this standard are:accounting machines monetary processing machinesbook-keeping machines including automated teller calculators (cash dispensing) machinescash registers motor-operated filescopying machines PABXsdata circuit terminating paper jogging machines equipment (e.g. modems) paper tape readers and punchersdata preparation equipment paper trimmers (punchers,data processing equipment cutting machines, separators)data terminal equipment pencil sharpenersdocument shredding machines personal computersduplicators photoprinting equipment electrically operated drawing plotters machines (plotters) point of sale terminals includingerasers associated electronic scalesfacsimile equipment postage machineskey telephone systems staplersmagnetic tape handlers telephone answering machines mail processing machines telephone sets micrographic office equipment teleprintersmodems text processing equipment typewriters visual display unitsThis list is not intended to be comprehensive, and equipment that is not listed is not necessarily excluded from the scope.Equipment complying with the relevant requirements in this standard is considered suitable for use with process control equipment, automatic test equipment and similar systems requiring information processing facilities. However, this standard does not include requirements for performance or functional characteristics of equipment.

Standards Relationship
IEC 60950:1991 Identical

In Australia First published as AS 3260-1988.
In New Zealand First published as NZS 6660:1987.
Revised and redesignated NZS 6661:1989.
AS 3260-1988 and NZS 6661:1989 revised, amalgamated and designated AS/NZS 3260:1993.

AS 3109.1-1987 Approval and test specification - Appliance couplers for household and similar general purposes - General requirements
AS 3116-1990 Approval and test specification - Electric cables - Elastomer insulated - For working voltages up to and including 0.6/1 kV
AS 1104-1978 Informative symbols for use on electrical and electronic equipment
AS 2768-1985 Electrical insulating materials - Evaluation and classification based on thermal endurance
AS 2420-1987 Fire test methods for solid insulating materials and non-metallic enclosures used in electrical equipment
AS 1541.14-1983 Fixed capacitors for use in electronic equipment - Fixed capacitors for radio interference suppression
AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
AS 2899.0-1986 Public information symbol signs - Consolidated index
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS 3250-1990 Approval and test specification - Mains operated electronic and related equipment for household and similar general use
AS 1612-1999 Paper sizes
AS 3147-1992 Approval and test specification - Electric cables - Thermoplastic insulated - For working voltages up to and including 0.6/1 kV
AS 3191-1981 Approval and test specification for electric flexible cords (incorporating Corrigenda)
AS 1660.3-1986 Methods of test for electric cables, cords and conductors - Electrical tests
AS 1721-1985 General purpose metric screw threads (Reconfirmed 2017)

AS/NZS 4579:1999 Micrographics - Reader-printers for transparent microforms - Characteristics (Reconfirmed 2016)
AS 4542.1-1999 Consumer television interfaces PAL RF (Reconfirmed 2016)
AS/NZS 4802.3:1999 Information processing systems - Local area networks Carrier sense multiple access with collision detection access method and physical layer specifications
AS 3590.1-1990 Screen-based workstations - Visual display units
AS 4079-1992 Information technology - 130 mm rewritable optical disk cartridge for information interchange
AS/NZS 4117:1999 Surge protective devices for telecommunication applications
AS 3811-1998 Hard-wired patient alarm systems
AS 3590.2-1990 Screen-based workstations - Workstation furniture
AS 2201.1-1998 Intruder alarm systems Systems installed in client’s premises
AS/NZS 2211.1:1997 Laser safety Equipment classification, requirements and user’s guide
AS 4933.1-2000 Digital television - Requirements for receivers VHF/UHF DVB-T television broadcasts
AS/NZS 3200.1.1:1995 Approval and test specification - Medical electrical equipment General requirements for safety - Collateral Standard: Safety requirements for medical electrical systems
AS/NZS 4117:1996 Surge suppression devices for telecommunication applications
AS/NZS 3080:1996 Telecommunications installations - Integrated telecommunications cabling systems for commercial premises
HB 94-1997 Electrical safety in the workplace
AS 4428.0-1997 Fire detection, warning, control and intercom systems - Control and indicating equipment General requirements and test methods (Reconfirmed 2016)
AS/NZS 3350.2.82:2000 Safety of household and similar electrical appliances Particular requirements for service machines and amusement machines (IEC 60335-2-82:1999, MOD)
AS 4262.1-1995 Telecommunication overvoltages Protection of persons
AS 3815-1998 A guide to coaxial cabling in single and multiple premises
AS/NZS 3250:1995 Approval and test specification - Mains operated electronic and related equipment for household and similar general use
AS 4070-1992 Recommended practices for protection of low-voltage electrical installations and equipment in MEN systems from transient overvoltages (Reconfirmed 2015)
AS/NZS 3350.2.56:1998 Safety of household and similar electrical appliances Particular requirements - Projectors and similar appliances
AS 3590.3-1990 Screen-based workstations - Input devices
AS 4080-1995 User terminals for accessing the mobilesat satellite communications system
AS 4802.5-1992 Information processing systems - Local area networks - Token ring access method and physical layer specifications
AS/NZS 4577:1999 Micrographics - Readers for transparent microforms - Performance characteristics (Reconfirmed 2016)
SAA HB37.2-1993 Handbook of Australian fire Standards Electrical equipment (Reconfirmed 2016)
AS 4262.2-1999 Telecommunication overvoltages Protection of equipment

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.