• Shopping Cart
    There are no items in your cart

AS/NZS 60079.18:2005

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection encapsulation m electrical apparatus

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-06-2017

Superseded by

AS/NZS 60079.18:2011

Language(s)

English

Published date

03-05-2005

€77.79
Excluding VAT

1 - AS/NZS 60079.18:2005 Electrical apparatus for explosive gas - Part 18: Construction, test and marking of type of protection encapsulation ‘m’ electrical apparatus
4 - PREFACE
5 - CONTENTS
7 - 1 Scope
7 - 2 Normative references
8 - 3 Definitions
9 - 4 General
9 - 4.1 Apparatus group and temperature classification
9 - 4.2 Level of protection
10 - 4.3 Level of protection “ma”
10 - 4.4 Level of protection “mb”
10 - 4.5 Supply specifications
10 - 5 Requirements for compounds
10 - 5.1 General
10 - 5.2 Specification
11 - 6 Temperatures
11 - 6.1 General
11 - 6.2 Temperature limitation
11 - 6.3 Determination of the limiting temperature
12 - 7 Constructional requirements
12 - 7.1 General
12 - 7.2 Determination of faults
14 - 7.3 Free space in the encapsulation
15 - 7.4 Thickness of the compound
20 - 7.5 Switching contacts
20 - 7.6 External connections
20 - 7.7 Protection of bare live parts
21 - 7.8 Cells and batteries
23 - 7.9 Protective devices
24 - 8 Type tests
24 - 8.1 Tests on the compound – water absorption test
24 - 8.2 Tests on the apparatus
28 - 9 Routine verifications and tests
28 - 9.1 Visual inspections
28 - 9.2 Dielectric strength test
28 - 10 Marking
29 - Annex A (informative) Basic requirements for compounds for “m” apparatus
30 - Annex B (normative) Allocation of test samples
31 - Annex C (normative) Test procedure during thermal cycling test

Specifies requirements for the construction, testing and marking of electrical apparatus, parts of electrical apparatus and Ex components with the type of protection encapsulation ‘m’. This part of AS/NZS 60079 only applies for encapsulated electrical apparatus, encapsulated parts of electrical apparatus and encapsulated Ex components where the rated voltage does not exceed 10 kV with a relative tolerance of +10 percent. This Standard supplements the general requirements in AS/NZS 60079.0. It is identical with and has been reproduced from IEC 60079-18:2004.

Committee
EL-014
DocumentType
Standard
ISBN
0 7337 6672 2
Pages
25
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Standards Relationship
IEC 60079-18:2004 Identical

Originated as AS 2431-1981.
Jointly revised and redesignated as AS/NZS 60079.18:2005.

AS/NZS 60079.26 (INT):2005 Electrical apparatus for explosive gas atmospheres Construction, test and marking of Group II Zone 0 electrical apparatus
AS 3731.2-1995 Stationary batteries - Nickel-cadmium Valve-regulated type
AS/NZS 60079.11:2000 Electrical apparatus for explosive gas atmospheres Intrinsic safety 'i'
AS/NZS 60079.7:2002
AS/NZS 60079.0:2005 Electrical apparatus for explosive gas atmospheres General requirements

AS 4647-2011 Diaphragm gas meters
AS/NZS 60335.2.11:2009 Household and similar electrical appliances - Safety Particular requirements for tumble dryers (IEC 60335-2-11 Ed 7.1, MOD)
AS/NZS 1300:2009 Electrical equipment for mines and quarries - Bolted explosion-protected three-phase cable coupling devices (Reconfirmed 2020)
AS/NZS 4024.1:2006 Series Safety of machinery Safety of machinery series
AS/NZS 60079.0:2008 Explosive atmospheres Equipment - General requirements
AS 4024.1202-2006 Safety of machinery General principles - Technical principles
AS/NZS 1680.1:2006 Interior and workplace lighting General principles and recommendations
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS 60204.11-2006 Safety of machinery - Electrical equipment of machines Requirements for HV equipment for voltages above 1000 V a.c. or 1500 V d.c and not exceeding 36 kV (IEC 60204-11, Ed. 1.0 (2000) MOD)
AS 60204.1-2005 Safety of machinery - Electrical equipment of machines General requirements (IEC 60204-1, Ed. 5 (FDIS) MOD)
HB 13-2007 Electrical equipment for hazardous areas
AS/NZS 60079.7:2006 Explosive atmospheres Equipment protection by increased safety 'e'
AS/NZS 4871.3:2010 Electrical equipment for mines and quarries Substations
AS/NZS 1299:2009 Electrical equipment for mines and quarries - Explosion-protected three-phase restrained plugs and receptacles for working voltages up to and including 3.3 kV (Reconfirmed 2020)
AS/NZS 60079.14:2009 Explosive atmospheres Electrical installations design, selection and erection (IEC 60079-14, Ed. 4.0 (2007) MOD)
AS/NZS 60079.26 (INT):2005 Electrical apparatus for explosive gas atmospheres Construction, test and marking of Group II Zone 0 electrical apparatus
AS/NZS 60079.26:2007 Explosive atmospheres Equipment with equipment protection level (EPL) Ga
AS/NZS 60079.28:2007 Explosive atmospheres Protection of equipment and transmission systems using optical radiation

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.