Electromagnetic compatibility (EMC) Limits - Limitation of voltage fluctuations and flicker in low-voltage power supply systems for equipment with rated current greater than 16 A
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
24-06-2021
English
05-05-1998
Specifies the limitation of voltage fluctuation and flicker in low-voltage supply systems for equipment with a rated input current greater than 16 A. This Standard is identical with and has been reproduced from IEC 61000-3-5:1994.
Committee |
EL-034
|
DocumentType |
Standard
|
ISBN |
0 7337 1919 8
|
Pages |
12
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This section of IEC 1000-3 is concerned with the emission of disturbances due to voltage fluctuations and flicker.The recommendations in this Technical Report are applicable to electrical and electronic equipment intended to be connected to a public low-voltage a.c. distribution system, where the equipment has a rated input current exceeding 16 A per phase, or has a lower rated current, but requires the special consent of the supply authority.The recommendations that specify the information required to enable a supply authority, manufacturer, or consumer to assess equipment and appropriate questionnaires are included as annexes A and B.Guidance is also given on emission values of voltage fluctuations produced by equipment which has been type tested to the specified conditions given in IEC 1000-3-3.NOTE 1 - The limits recommended in this report are mainly based on the subjective severity of the flicker of the light output from 230 V/60 W coiled-coil filament lamps as a result of fluctuation of the supply voltage. For systems with nominal voltages less than 220 V, line-to-neutral, limits, and reference circuit values have not yet been considered.The authorization to connect equipment to the supply depends on the levels of disturbance caused by the equipment and the load flow conditions in the network.NOTE 2 -- For equipment requiring authorization, only general recommendations for the assessment of disturbances can be given. There is no guarantee that the connection of equipment complying with the recommendations in clause 3 will be allowed in all cases, as system loading must not exceed plant ratings (transformers, cables, etc.).The methods of assessment may be applied also to private consumer installations.
Standards | Relationship |
IEC TS 61000-3-5:1994 | Identical |
First published as AS/NZS 6100.3.5:1998.
AS/NZS 61000.3.2:1998 | Electromagnetic compatibility (EMC) Limits - Limits for harmonic current emissions (equipment input current less than or equal to 16 A per phase) |
AS/NZS 61000.3.3:1998 | Electromagnetic compatibility (EMC) Limits - Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current less than or equal to 16 A |
AS/NZS 61000.3.3:1998 | Electromagnetic compatibility (EMC) Limits - Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current less than or equal to 16 A |
AS/NZS 61058.1:2008 | Switches for appliances General requirements (IEC 61058-1, Ed. 3.1 (2000), MOD) |
AS 2703-2008 | Vehicle loop detector sensors |
AS/NZS 61000.3.3:2003 | Electromagnetic compatibility (EMC) Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current less than or equal to 16A per phase and not subject to conditional connection |
AS 4777.3-2002 | Grid connection of energy systems via inverters - Grid protection requirements |
AS/NZS 4871.1:2010 | Electrical equipment for mines and quarries General requirements |
AS/NZS 61000.4.1:2006 | Electromagnetic compatibility (EMC) Testing and measurement techniques - Overview of IEC 61000-4 series |
AS 1418.1-2002 | Cranes, hoists and winches General requirements |
AS 4777.2-2002 | Grid connection of energy systems via inverters - Inverter requirements |
AS/NZS 61000.3.4:2007 | Electromagnetic compatibility (EMC) Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 75 A (Reconfirmed 2018) |
AS/NZS 61000.3.3:2006 | Electromagnetic compatibility (EMC) Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current per phase and not subject to conditional connection |
AS 2067-2008 | Substations and high voltage installations exceeding 1 kV a.c. |
AS 61800.3-2001 | Adjustable speed electrical power drive systems - EMC product standard including specific test methods |
AS 4777.3-2005 | Grid connection of energy systems via inverters Grid protection requirements |
AS/NZS 61000.3.7:2001 | Electromagnetic compatibility (EMC) Limits - Assessment of emission limits for fluctuating loads in MV and HV power systems (IEC 61000-3-7:1996, MOD) |
AS 4777.2-2005 | Grid connection of energy systems via inverters Inverter requirements |
AS/NZS 4871.1:2012 | Electrical equipment for mines and quarries General requirements |
AS/NZS 3007:2013 | Electrical equipment in mines and quarries - Surface installations and associated processing plant |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.