AS/NZS 61558.1:2000
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
29-05-2024
27-12-2000
Specifies general safety requirements for approval and test purposes. This Standard is an adoption with national modifications and contains the full text of IEC 61558-1:1998.
Committee |
EL-002
|
DocumentType |
Standard
|
ISBN |
0 7337 3685 8
|
Pages |
124
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
1.1 This International Standard deals with all aspects of safety (such as electrical, thermal and mechanical) of:a) Stationary or portable, single-phase or polyphase, air-cooled (natural or forced) isolating and safety isolating transformers, associated or otherwise, having a rated supply voltage not exceeding 1 000 V a.c. and rated frequency not exceeding 1 MHz, the rated output not exceeding the following values. NOTE 1 – For higher frequencies, this standard may be used as a guidance document. for isolating transformers: – 25 kVA for single-phase transformers; – 40 kVA for polyphase transformers. For safety isolating transformers: – 10 kVA for single-phase transformers; – 16 kVA for polyphase transformers. The no-load output voltage and rated output voltage do not exceed: – for isolating transformers 500 V a.c. or 708 V ripple free d.c. NOTE 2 – For isolating transformers, the no-load rated output voltage may be up to 1 000 V a.c. or 1 415 V ripple free d.c. to be in accordance with the national wiring rules or for special purposes. – for safety isolating transformers 50 V a.c. r.m.s. and/or 120 V ripple free d.c. between conductors or between any conductor and earth. NOTE 3 – Isolating and safety isolating transformers are used where double or reinforced insulation between circuits is required by the installation rules or by the appliance specification (for example toys, bells, portable tools, handlamps). Rated values for each type of transformer are indicated in the relevant part 2. b) Stationary or portable, single-phase or polyphase, air-cooled (natural or forced) separating transformers, auto-transformers, variable transformers and small reactors, associated or not, having a rated supply voltage not exceeding 1 000 V a.c., a rated frequency not exceeding 1 MHz, a rated no-load or load output voltage not exceeding 15 kV a.c. or d.c., and for independent transformers not less than 50 V a.c. and/or 120 V ripple free d.c. and a rated output not exceeding the following values: – 1 kVA for single-phase transformers; – 5 kVA for polyphase transformers; – 10 kVAR for polyphase reactors; unless otherwise specified in the relevant part 2. NOTE 1 – Separating transformers are used where double or reinforced insulation between circuits is not required by the installation rules or by the appliance specification. NOTE 2 – The technological development of transformers might imply a need to increase the higher limit of the rated frequency. NOTE 3 – Normally, the transformers are intended to be associated with equipment to provide voltages different from the supply voltage for the functional requirement of the equipment. The safety insulation may be provided (or completed) by other features of the equipment, such as the body. Parts of output circuits may be connected to the input circuit or to protective earth. c) Power supply units incorporating a transformer of types a) or b). NOTE 1 – This may include units for transforming, rectifying, converting, frequency inverting or their combinations intended for power supplying electrical equipment, except for switch-mode power supplies. NOTE 2 – Examples of power supply units are transformers, battery eliminators and converters for building-in or self-contained. In the latter case they can even be provided with integrated pins, intended to be introduced into fixed socket-outlets. NOTE 3 – Requirements for transformers for switch-mode power supplies are contained in IEC 61558-2-17. 1.2 This standard is applicable to dry type transformers. The windings may be encapsulated or non-encapsulated. NOTE 1 – For transformers filled with liquid dielectric or pulverised material, such as sand, requirements are under consideration. This standard is also applicable to transformers associated with specific items of equipment, to the extent decided upon by the relevant IEC technical committees. Transformers incorporating electronic circuits are also covered by this standard. This standard does not apply to external circuits and their components connected to terminals or socket-outlets of the transformer. NOTE 2 – Examples are wiring, fuses and switches. NOTE 3 – Attention is drawn to the fact that: – for transformers intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary; – for transformers intended to be used in tropical countries, special requirements may be necessary; – in locations where special environmental conditions prevail, particular requirements may be necessary in accordance with IEC 60364-5-51. – 2 kVAR for single-phase reactors;
First published in Australia as AS C126-1939.
Second edition 1951.
Third edition 1954.
Fourth edition 1958.
AS C167 first published 1962.
AS C126-1958 revised and redesignated as AS 3126-1981.
AS C167-1962 revised and redesignated as AS 3167-1981.
AS 3126-1981 and AS 3167-1981 revised and redesignated as AS 3108.1-1984, AS 3108.2-1984 and AS 3108.3-1984.
AS 3108.1-1984, AS 3108.2-1984 and AS 3108.3-1984 revised, amalgamated and redesignated as AS 3108-1990.
First published in New Zealand as NZS/AS 3108:1990.
AS 3108-1990 and NZS/AS 3108:1990 jointly revised and designated as AS/NZS 3108:1994.
AS/NZS 3108:1994 jointly revised and redesignated as AS/NZS 61558.1:2000.
AS/NZS 3109.1:1996 | |
AS/NZS 61000.3.2:1998 | Electromagnetic compatibility (EMC) Limits - Limits for harmonic current emissions (equipment input current less than or equal to 16 A per phase) |
AS/NZS 4695.2.10:1996 | Fire hazard testing of electrotechnical products Test methods - Glow-wire test methods - General |
AS/NZS 3000:2000 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 1104-1978 | Informative symbols for use on electrical and electronic equipment |
AS/NZS 4695.112:1996 | Fire hazard testing of electrotechnical products Method for determining the comparative and the proof tracking indices of solid insulating materials under moist conditions |
AS/NZS 60998.1:1998 | Connecting devices for low voltage circuits for household and similar purposes General requirements |
AS 1621.3.3-1988 | Pressure-sensitive adhesive electrical tapes Polyester film tapes (PETP) with non-thermosetting adhesive |
AS 2768-1985 | Electrical insulating materials - Evaluation and classification based on thermal endurance |
AS/NZS 60998.2.1:1998 | Connecting devices for low voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with screw-type clamping units |
AS/NZS 3139.1:1995 | Approval and test specification - Switches for appliances General requirements |
AS/NZS 61000.3.3:1998 | Electromagnetic compatibility (EMC) Limits - Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current less than or equal to 16 A |
AS/NZS 4695.707:1996 | Fire hazard testing of electrotechnical products Methods of test for the determination of the flammability of solid electrical insulating materials when exposed to an igniting source |
AS 1621.2-1988 | Pressure-sensitive adhesive electrical tapes Methods of test |
AS 1621.3.4-1988 | Pressure-sensitive adhesive electrical tapes Cellulosic paper tapes, creped, with thermosetting adhesive |
AS 1939-1990 | Degrees of protection provided by enclosures for electrical equipment (IP Code) |
AS 1621.3.5-1988 | Pressure-sensitive adhesive electrical tapes Cellulosic paper tapes with thermosetting adhesive |
AS 2005.30-1991 | Low voltage fuses - Fuses with enclosed fuse-links - Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) |
AS 2752-1985 | Preferred numbers and their use |
AS 1621.3.1-1988 | Pressure-sensitive adhesive electrical tapes Plasticized polyvinyl chloride tapes with non-thermosetting adhesive |
AS 1621.3.2-1988 | Pressure-sensitive adhesive electrical tapes Polyester film tapes (PETP) with thermosetting adhesive |
AS/NZS 3250:1995 | Approval and test specification - Mains operated electronic and related equipment for household and similar general use |
AS 2005.21.1-1990 | Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) - Standardized fuse systems - Fuses with fuse-links with blade contacts |
AS 1621.1-1988 | Pressure-sensitive adhesive electrical tapes - General requirements |
AS 3947.7.1-1996 | Low-voltage switchgear and controlgear Ancillary equipment - Terminal blocks for copper conductors |
AS/NZS 4695.2.11:1996 | Fire hazard testing of electrotechnical products Test methods - Glow-wire end-product test and guidance |
AS 2374.1-1997 | Power transformers General |
AS/NZS 3191:1996 | Approval and test specification - Electric flexible cords |
AS/NZS 4898:1997 | Approval and test specification - Circuit-breakers for overcurrent protection for household and similar installations |
AS 2005.20-1990 | Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) - Common requirements |
AS/NZS 60998.2.2:1998 | Connecting devices for low voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with screwless-type clamping units |
AS/NZS IEC 61347.2.13:2013 | Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules (IEC 61347-2-13, Ed.1.0 (2006) MOD) |
AS 2703-2008 | Vehicle loop detector sensors |
AS/NZS 4836:2011 | Safe working on or near low-voltage electrical installations and equipment |
AS/NZS 3002:2008 | Electrical installations - Shows and carnivals |
AS 2865-2009 | Confined spaces |
AS/NZS 3439.4:2009 | Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS) |
AS/NZS 60745.1:2009 | Hand-held motor-operated electric tools-Safety General requirements (IEC 60745-1 Ed 4, MOD) (Reconfirmed 2020) |
AS/NZS 3197:2005 | Approval and test specification - Portable electrical control or conditioning devices |
AS/NZS 3004.2:2008 | Electrical installations - Marinas and recreational boats Recreational boats installations |
AS/NZS 4879.1:2008 | Performance of transformers and electronic step-down convertors for ELV lamps Test method - Energy performance (Reconfirmed 2017) |
AS 2144:2014 | Traffic signal lanterns |
AS/NZS 3105:2014 | Approval and test specification - Electrical portable outlet devices |
AS/NZS 60065:2003 | Audio, video and similar electronic apparatus - Safety requirements (IEC 60065:2001, MOD) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 61347.2.2:2007 | Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps (IEC 61347-2-2, Ed. 1.2 (2006) MOD) |
AS/NZS 60065:2012 | Audio, video and similar electronic apparatus - Safety requirements (IEC 60065, Ed.7.2 (2011) MOD) |
AS 3533.2-2009 | Amusement rides and devices Operation and maintenance |
AS/NZS 60745.1:2003 | Hand-held motor-operated electric tools - Safety General requirements (IEC 60745-1:2001, MOD) |
AS 60204.1-2005 | Safety of machinery - Electrical equipment of machines General requirements (IEC 60204-1, Ed. 5 (FDIS) MOD) |
AS 3533.1-2009 | Amusement rides and devices Design and construction |
AS 2832.3-2005 | Cathodic protection of metals Fixed immersed structures |
AS/NZS 4763(INT):2006 | Safety of Portable Inverters |
AS/NZS 3350.1:2002 | Safety of household and similar electrical appliances General requirements (IEC 60335-1:1991, MOD) |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 2832.4-2006 | Cathodic protection of metals Internal surfaces (Reconfirmed 2016) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.