1. Scope and normative references
2. Definitions
3. General requirements
4. General notes on tests
5. Rating
6. Classification
7. Information
8. Protection against electric shock
9. Provision for protective earthing
10. Terminals and terminations
11. Constructional requirements
12. Moisture and dust resistance
13. Electric strength and insulation resistance
14. Heating
15. Manufacturing deviation and drift
16. Environmental stress
17. Endurance
18. Mechanical strength
19. Threaded parts and connections
20. Creepage distances, clearances and distances
through solid insulation
21. Resistance to heat, fire and tracking
22. Resistance to corrosion
23. Electromagnetic compatibility (EMC) requirements -
emission
24. Components
25. Normal operation
26. Electromagnetic compatibility (EMC) requirements -
immunity
27. Abnormal operation
28. Guidance on the use of electronic disconnection
Annexes
A (normative) - Indelibility of markings
B (normative) - Measurement of creepage distances and
clearances in air
C (normative) - Cotton used for mercury switch test
D (informative) - Heat, fire and tracking
E (informative) - Circuit for measuring leakage current
F (informative) - Heat and fire resistance categories
G (normative) - Heat and fire resistance tests
H (normative) - Requirements for electronic controls
J (normative) - Requirements for controls using thermistors
K (informative) - Nominal voltages of supply systems for
different modes of overvoltage control
L (normative) - Overvoltage categories
M (informative) - Typical usage
N (normative) - Pollution degrees
P (normative) - Printed circuit board coating performance test
Q (normative) - Printed circuit board coating performance test
R (informative) - Explanatory notes for surge immunity test
S (informative) - Guidance for applying clause 20
Key-word index
Specifies automatic electrical controls for use in, on, or in association with equipment for household and similar use, including controls for heating, air-conditioning and similar applications.
DevelopmentNote |
Issue Date: 01/10/2008. (04/2009)
|
DocumentType |
Standard
|
PublisherName |
Bureau of Indian Standards
|
Status |
Current
|
Standards | Relationship |
IEC 60730-1:2013+AMD1:2015 CSV | Identical |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60038:2009 | IEC standard voltages |
IEC 60738-1:2006+AMD1:2009 CSV | Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification |
IEC 60127:1974 | Cartridge fuse-links for miniature fuses |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60539:1976 | Directly heated negative temperature coefficient thermistors |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60998-2-2:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
IEC 60738-1-1:2008 | Thermistors - Directly heated positive step-function temperature coefficient - Part 1-1: Blank detail specification - Current limiting application - Assessment level EZ |
IEC 60099-1:1991+AMD1:1999 CSV | Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60423:2007 | Conduit systems for cable management - Outside diameters of conduits for electrical installations and threads for conduits and fittings |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.