BS 415(1998) : 1998
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS
01-03-2007
23-11-2012
Foreword
Introduction - Principles of safety
1 General
1.1 Scope
1.2 Normative references
2 Definitions
3 General requirements
4 General test conditions
5 Marking and instructions
6 Hazardous radiations
7 Heating under normal operating conditions
8 Constructional requirements with regard to the
protection against electric shock
9 Electric shock hazard under normal operating
conditions
10 Insulation requirements
11 Fault conditions
12 Mechanical strength
13 CLEARANCES and CREEPAGE DISTANCES
14 Components
15 TERMINALS
16 External flexible cords
17 Electrical connections and mechanical fixings
18 Mechanical strength of picture tubes and protection
against the effects of implosion
19 Stability and mechanical hazards
20 Resistance to fire
Annex A (normative) Additional requirements for apparatus
with protection against splashing water
Annex B (normative) Apparatus to be connected to
TELECOMMUNICATION NETWORKS
Annex C (normative) Band-pass filter for wide-band noise
measurement
Annex D (normative) Measuring network for touch-currents
Annex E (normative) Measurement of clearances and creepage
distances
Annex F (normative) Table of electrochemical potentials
Annex G (normative) Flammability test methods
Annex H - Free
Annex I - Free
Annex J - Free
Annex K - Free
Annex L - Free
Annex M - Free
Annex N (informative) ROUTINE TEST
Annex P (informative) Bibliography
Annex ZA (normative) Other international publications quoted
in this standard with the references
of the relevant European publications
Annex ZB (normative) Special national conditions
Annex AC (informative) A-deviations
Figure 1 - Test circuit for fault conditions
Figure 2 - Example of an assessment of REINFORCED INSULATION
Figure 3 - Example of ACCESSIBLE parts
Figure 4 - Test hook
Figure 5a - Surge test - Test circuit
Figure 5b - Surge test - Example of a switch to be used in
the test circuit
Figure 6 - Dielectric strength test instrument
Figure 7 - Test voltages
Figure 8 - Test plug for mechanical tests on antenna coaxial
sockets
Figure 9 - CLEARANCES and CREEPAGE DISTANCES
Figure 10 - Minimum CLEARANCES and CREEPAGE DISTANCES on
PRINTED BOARDS
Figure 11 - Test apparatus for devices forming a part of the
MAINS plug
Figure 12 - Scratch patterns for implosion test
Figure 13 - Distances from POTENTIAL IGNITION SOURCES
Figure B.1 - Test probe
Figure C.1 - Band-pass filter for wide-band noise measurement
(amplitude/frequency response limits, see below)
Figure D.1 - Measuring network for TOUCH CURRENTS according
to IEC 60990
Figure E.1 - Narrow grove
Figure E.2 - Wide groove
Figure E.3 - V-shaped groove
Figure E.4 - Rib
Figure E.5 - Uncemented joint with narrow groove
Figure E.6 - Uncemented joint with wide groove
Figure E.7 - Uncemented joint with narrow and wide grooves
Figure E.8 - Intervening, unconnected conductive part
Figure E.9 - Narrow recess
Figure E.10 - Wide recess
Table 1 - Test power supply
Table 2 - Permissible temperature rise of parts of the
apparatus
Table 3 - Test voltages for dielectric strength test and
values for insulation resistance
Table 4 - Minimum CLEARANCES and CREEPAGE DISTANCES
Table 5 - Flammability category related to distance from
POTENTIAL IGNITION SOURCES
Table 6 - Peak surge current
Table 7 - Nominal cross-sectional area to be accepted by
TERMINALS
Table 8 - Minimum nominal thread diameter
Table 9 - Pull force on pins
Table 10 - Nominal cross-sectional areas of external flexible
cords
Table 11 - Mass and pulley diameter for stress test
Table 12 - Torque to be applied to screws
Table 13 - Distance to POTENTIAL IGNITION SOURCES
Table N.1 - Test voltage
Gives safety requirements for apparatus that is connected to the supply mains (directly or indirectly) and is meant for domestic and similar general indoor use (not subject to dripping or splashing). Coverage includes the following sections: marking and instructions for use; heating under normal operation conditions; mechanical strength of picture tubes and protection against the effects of implosion; resistance to fire of television receivers. Also gives detailed definitions.
Committee |
EPL/92
|
DevelopmentNote |
SUPERSEDES BS 415(1994) WHICH WILL REMAIN CURRENT UNTIL FURTHER NOTICE
|
DocumentType |
Standard
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60038:2009 | IEC standard voltages |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60950:1999 | Safety of information technology equipment |
IEC 61293:1994 | Marking of electrical equipment with ratings related to electrical supply - Safety requirements |
IEC 61250:1994 | Nuclear reactors - Instrumentation and control systems important for safety - Detection of leakage in coolant systems |
IEC 60825-1:2014 | Safety of laser products - Part 1: Equipment classification and requirements |
IEC 60885-1:1987 | Electrical test methods for electric cables. Part 1: Electrical tests for cables, cords and wires for voltages up to and including 450/750 V |
IEC 60384-1:2016 | Fixed capacitors for use in electronic equipment - Part 1: Generic specification |
IEC 60167:1964 | Methods of test for the determination of the insulation resistance of solid insulating materials |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
ISO 262:1998 | ISO general purpose metric screw threads — Selected sizes for screws, bolts and nuts |
IEC 60998-2-2:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
IEC 60691:2015 | Thermal-links - Requirements and application guide |
IEC 60268-1:1985 | Sound system equipment. Part 1: General |
ISO 306:2013 | Plastics — Thermoplastic materials — Determination of Vicat softening temperature (VST) |
ISO 261:1998 | ISO general purpose metric screw threads — General plan |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.