BS 5588-3:1983
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Fire precautions in the design, construction and use of buildings Code of practice for office buildings
Hardcopy , PDF
15-07-1997
English
29-07-1983
Foreword
Committees responsible
Code of practice
Section one. General
1 Scope
2 Definitions
3 Use of this code
Section two. Analysis of the problem
4 Planning in relation to fire
5 Escape from fire
Section three. Planning of escape from office areas
6 General
7 Escape routes within, and exits from, a storey
8 Stairways and final exits
Section four. Construction and fire safety signs and
notices
9 Construction
10 Fire safety signs and notices
Section five. Engineering services (other than fire
protection facilities) and ancillary
accommodation
11 General
12 Electrical services
13 Lighting
14 Heating and fuel storage
15 Mechanical ventilation, air conditioning and
pressurization
16 Lifts
17 Waste storage and incinerators
18 Main storage areas (including receiving and dispatch
areas) and loading bays
19 Car parks
20 Repair or maintenance workshops and reprographic
rooms
21 Kitchens, restaurants and canteens
22 Data processing areas
Section six. Fire protection facilities
23 General
24 Fire alarms and fire detection and alarm systems
25 Automatic fire extinguishing systems and special
risk protection
26 Manual fire-fighting equipment
27 Water supplies for fire-fighting
28 Fireman's emergency switches for discharge lighting
installations
29 Access for fire-fighting
30 Smoke control provisions other than for fire-
fighting shafts
31 Plans for fire brigade use
Appendix
A Advice to management and procedure in case of fire
Planning, construction and protection of escape routes for occupants to use in the event of fire. Recommendations for fire precautions in engineering services and auxiliary accommodation, and for fire alarms and procedures, extinguishing and fire fighting equipment, water supplies, access for fire fighting and smoke control. Advice on the management of completed buildings.
Committee |
FSH/14
|
DevelopmentNote |
REPLACES CP 3: CHAPTER 4: PART 3:1968.
|
DocumentType |
Standard
|
Pages |
52
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 62343-2:2011 | Identical |
UNE-EN 1614:2007 | Identical |
BS 5395-3:1985 | Stairs, ladders and walkways Code of practice for the design of industrial type stairs, permanent ladders and walkways |
BS 5395-1:1977 | Stairs, ladders and walkways Code of practice for the design of straight stairs |
BS 5588-10:1991 | Fire precautions in the design, construction and use of buildings Code of practice for shopping complexes |
BS 6229:2003 | Flat roofs with continuously supported coverings. Code of practice |
BS 6259:1997 | Code of practice for the design, planning, installation, testing and maintenance of sound systems |
BS 5588-6:1991 | Fire precautions in the design, construction and use of buildings Code of practice for places of assembly |
BS 5395-2:1984 | Stairs, ladders and walkways Code of practice for the design of helical and spiral stairs |
BS 5588-2:1985 | Fire precautions in the design, construction and use of buildings Code of practice for shops |
BS 8220-2:1987 | Guide for security of buildings against crime Offices and shops |
PD 6531:1997 | Queries and interpretations on BS 5839:Parts 1 and 4 (as amended) |
BS 6266:1992 | Code of practice for fire protection for electronic data processing installations |
BS 8220-2:1995 | Guide for security of buildings against crime Offices and shops |
BS 5588-4:1978 | Fire precautions in the design, construction and use of buildings Code of practice for smoke control in protected escape routes using pressurization |
BS 7083:1996 | Guide to the accommodation and operating environment for information technology (IT) equipment |
BS 7083:1989 | Recommendations for the accommodation and operating environment of computer equipment |
BS 8214:1990 | Code of practice for fire door assemblies with non-metallic leaves |
BS 6492-2:1985 | Transportable accommodation units Recommendations for transportation and siting, with guidance on occupancy |
PD 6531:1992 | Queries and interpretations on BS 5839:Parts 1 and 4 (as amended) |
BS 5234-1:1992 | Partitions (including matching linings) Code of practice for design and installation |
BS 476-23:1987 | Fire tests on building materials and structures Methods for determination of the contribution of components to the fire resistance of a structure |
BS 476-4:1970 | Fire tests on building materials and structures Non-combustibility test for materials |
BS 5588-9:1989 | Fire precautions in the design, construction and use of buildings Code of practice for ventilation and air conditioning ductwork |
BS 5410-1:1977 | Code of practice for oil firing Installations up to 44 kW output capacity for space heating and hot water supply purposes |
PD 6512-1:1985 | Use of elements of structural fire protection with particular reference to the recommendations given in BS 5588 \'Fire precautions in the design and construction of buildings\' Guide to fire doors |
BS 5839-1:1988 | Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing |
BS 5306-5.2:1984 | Code of practice for fire extinguishing installations and equipment on premises. Halon systems Halon 1211 total flooding systems |
BS 5306-5.1(1982) : 1982 | FIRE EXTINGUISHING INSTALLATIONS AND EQUIPMENT ON PREMISES - HALON SYSTEMS - HALON 1301 TOTAL FLOODING SYSTEMS |
BS CP3:CH5-2(1972) : AMD 7908 | CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - LOADING - WIND LOADS |
PD 6512-3:1987 | Use of elements of structural fire protection with particular reference to the recommendations given in BS 5588 \'Fire precautions in the design and construction of buildings\' Guide to the fire performance of glass |
BS 476-20:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of elements of construction (general principles) |
BS 476-21:1987 | Fire tests on building materials and structures Methods for determination of the fire resistance of loadbearing elements of construction |
BS 6459-1:1984 | Door closers Specification for mechanical performance of crank and rack and pinion overhead closers |
BS 5306-6.2:1989 | Fire extinguishing installations and equipment on premises. Foam systems Specification for medium and high expansion foam systems |
BS 5306-1:1976 | Fire extinguishing installations and equipment on premises Hydrant systems, hose reels and foam inlets |
BS 5588-8:1988 | Fire precautions in the design, construction and use of buildings Code of practice for means of escape for disabled people |
BS 5839-3:1988 | Fire detection and alarm systems for buildings Specification for automatic release mechanisms for certain fire protection equipment |
BS 5852-1:1979 | Fire tests for furniture Methods of test for the ignitability by smokers\' materials of upholstered composites for seating |
BS 5395-1:1977 | Stairs, ladders and walkways Code of practice for the design of straight stairs |
BS 5410-2:1978 | Code of practice for oil firing Installations of 45 kW and above output capacity for space heating, hot water and steam supply services |
BS 5588-4:1978 | Fire precautions in the design, construction and use of buildings Code of practice for smoke control in protected escape routes using pressurization |
BS 5395-2:1984 | Stairs, ladders and walkways Code of practice for the design of helical and spiral stairs |
BS CP3:CH4-1(1971) : AMD 2708 | CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - PRECAUTIONS AGAINST FIRE - FLATS AND MAISONETTES - (IN BLOCKS OVER TWO STOREYS) |
BS 476-31.1:1983 | Fire tests on building materials and structures Methods for measuring smoke penetration through doorsets and shutter assemblies - Method of measurement under ambient temperature conditions |
BS 5306-2:1979 | Fire extinguishing installations and equipment on premises Sprinkler systems |
BS 5306-3:1985 | Fire extinguishing installations and equipment on premises Code of practice for selection, installation and maintenance of portable fire extinguishers |
BS 476-8:1972 | Fire tests on building materials and structures Test methods and criteria for the fire resistance of elements of building construction |
BS 476-22:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.