BS 5588-7:1997
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Fire precautions in the design, construction and use of buildings Code of practice for the incorporation of atria in buildings
Hardcopy , PDF
06-10-2008
English
15-08-1999
Committees responsible
Foreword
Section 1. General
1 Scope
2 References
3 Definitions
4 Use of the code
Section 2. Analysis of the problem
5 Fire in the atrium building
6 Functional design requirements
Section 3. Occupancy and building characteristics
7 Occupancy characteristics
8 Compartmentation of fire resistance
9 Connection of atrium to below-ground storeys
10 Use of atrium base
Section 4. Fire protection facilities
11 Means of escape
12 Evacuation procedures
13 Fire control centre
14 Fire warning systems
15 Automatic fire detection
16 Separation between atrium and associated floor area
17 Smoke control for means of escape
18 Sprinkler systems
19 Electrical services
20 Facilities for firefighting
Section 5. Design solutions
21 General
Section 6. Recommendations
22 Recommendations for means of escape
23 Recommendations for separation between the atrium and
the associated floor area
24 Recommendations for smoke and heat control systems
25 Recommendations for sprinkler systems
26 Recommendations for fire alarm and warning systems
27 Recommendations for controlling fire load on the atrium
base
28 Recommendations for all designs
29 Facilities for firefighting
Section 7. Management
Annex A (informative) Exemplars
Annex B (normative) Commissioning and hand-over of smoke
control systems
List of references
Provides guidance on the incorporation of one or more atria into new and existing buildings. The primary objective of the code is to ensure that the incorporation of an atrium into a building does not present an increased risk to life as a result of fire and smoke spread.
Committee |
FSH/14
|
DevelopmentNote |
Supersedes 90/43820 DC. (07/2002) Reviewed and confirmed by BSI, January 2008. (12/2007)
|
DocumentType |
Standard
|
Pages |
96
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
BS 5588-11:1997 | Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings |
BS 5588-10:1991 | Fire precautions in the design, construction and use of buildings Code of practice for shopping complexes |
03/117591 DC : DRAFT NOV 2003 | BS 7346-5 - COMPONENTS FOR SMOKE AND HEAT CONTROL SYSTEMS - PART 5: CODE OF PRACTICE ON FUNCTIONAL RECOMMENDATIONS AND CALCULATION METHODS FOR SMOKE AND HEAT EXHAUST VENTILATION SYSTEMS, EMPLOYING TIME DEPENDENT DESIGN FIRES |
BS 6229:2003 | Flat roofs with continuously supported coverings. Code of practice |
PD 6686:2006 | Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries |
BS 5499-4:2000 | Safety signs, including fire safety signs. Code of practice for escape route signing |
BS 5588-4:1998 | Fire precautions in the design, construction and use of buildings Code of practice for smoke control using pressure differentials |
BS 5588-5:1991 | Fire precautions in the design, construction and use of buildings Code of practice for firefighting stairs and lifts |
BS 7346-4:2003 | Components for smoke and heat control systems Functional recommendations and calculation methods for smoke and heat exhaust ventilation systems, employing steady-state design fires. Code of practice |
CEN/TR 12101-5:2005 | Smoke and heat control systems - Part 5: Guidelines on functional recommendations and calculation methods for smoke and heat exhaust ventilation systems |
BS 5839-8:1998 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning, and maintenance of voice alarm systems |
I.S. CEN/TR 12101-5:2005 | SMOKE AND HEAT CONTROL SYSTEMS - PART 5: GUIDELINES ON FUNCTIONAL RECOMMENDATIONS AND CALCULATION METHODS FOR SMOKE AND HEAT EXHAUST VENTILATION SYSTEMS |
BS 5588-9:1989 | Fire precautions in the design, construction and use of buildings Code of practice for ventilation and air conditioning ductwork |
BS 7346-2:1990 | Components for smoke and heat control systems Specification for powered smoke and heat exhaust ventilators |
BS EN 1021-1:2014 | Furniture. Assessment of the ignitability of upholstered furniture Ignition source smouldering cigarette |
BS 7346-3:1990 | Components for smoke and heat control systems Specification for smoke curtains |
BS 6206:1981 | Specification for impact performance requirements for flat safety glass and safety plastics for use in buildings |
BS 5839-1:1988 | Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing |
BS 5588-11:1997 | Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings |
BS 5588-6:1991 | Fire precautions in the design, construction and use of buildings Code of practice for places of assembly |
BS 476-20:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of elements of construction (general principles) |
BS 7671(2001) : 2001 AMD 14905 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS |
BS 5588-10:1991 | Fire precautions in the design, construction and use of buildings Code of practice for shopping complexes |
BS 476-21:1987 | Fire tests on building materials and structures Methods for determination of the fire resistance of loadbearing elements of construction |
BS 5852:1990 | Methods of test for assessment of the ignitability of upholstered seating by smouldering and flaming ignition sources |
BS 5588-4:1978 | Fire precautions in the design, construction and use of buildings Code of practice for smoke control in protected escape routes using pressurization |
BS 476-31.1:1983 | Fire tests on building materials and structures Methods for measuring smoke penetration through doorsets and shutter assemblies - Method of measurement under ambient temperature conditions |
BS 7346-1:1990 | Components for smoke and heat control systems Specification for natural smoke and heat exhaust ventilators |
BS 476-22:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction |
BS 5867-2:1980 | Specification for fabrics for curtains and drapes Flammability requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.