Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Fire survival times
6 Power supplies
7 Dual circuits/diverse routes
8 Fire protective enclosures for equipment
9 Automatic changeover devices
10 Motor control panels
11 Cable selection
12 Fire protective enclosures for cables
13 Effects of fire temperature on cable size
14 Use of circuit protective conductors (CPCs)
15 Cable installation practice
16 Cable support systems
17 Inverters
18 Multi-zoned smoke ventilation systems
19 Junction boxes
20 Areas of special fire risk
Annexes
Annex A (informative) - Typical medium voltage circuit
in a building
Annex B (normative) - Testing of Category 3 cables of
core sizes up to and including 4 mm[2]
cross-sectional area
Annex C (informative) - Voltage drop calculations for
cables in a fire
Annex D (informative) - Fire-resistant cables under fire
and fault conditions
Annex E (normative) - Methodology for determining the
cross-sectional area of drop rods
Annex F (informative) - Multi-zoned smoke ventilation
systems
Bibliography
Provides guidance and recommendations on the selection and installation of power and control cable systems which are required to maintain their circuit integrity for life safety and fire-fighting applications.
Committee |
FSH/1
|
DevelopmentNote |
Supersedes BS 7346-6(2005) and 09/30189450 DC. (02/2010)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This British Standard gives guidance and recommendations on the selection and installation of power and control cable systems which are required to maintain their circuit integrity for life safety and fire-fighting applications. It also gives specific recommendations for electrical system design for such applications, and recommended limits for survival times.
This British Standard does not give recommendations for those installations covered in BS5839‑1, BS5839‑8, BS5839‑9 and BS5266‑1, but makes reference to these standards in an informative capacity.
BS 9990:2015 | Non automatic fire-fighting systems in buildings. Code of practice |
BS 9991:2011 | Fire safety in the design, management and use of residential buildings. Code of practice |
BS 9999:2017 | Fire safety in the design, management and use of buildings. Code of practice |
BS 7346-8:2013 | Components for smoke control systems Code of practice for planning, design, installation, commissioning and maintenance |
BS 7846:2015 | Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS 7629-1:2015+A1:2019 | Electric cables. Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire Multicore cables |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 5266-1:2016 | Emergency lighting Code of practice for the emergency lighting of premises |
BS 9991:2015 | Fire safety in the design, management and use of residential buildings. Code of practice |
11/30227604 DC : 0 | BS 5266-1 - EMERGENCY LIGHTING - PART 1: CODE OF PRACTICE FOR THE EMERGENCY ESCAPE LIGHTING OF PREMISES |
11/30189447 DC : 0 | BS 6266 - FIRE PROTECTION FOR ELECTRONIC EQUIPMENT INSTALLATIONS - CODE OF PRACTICE |
14/30301827 DC : 0 | BS 9990 - NON-AUTOMATIC FIRE-FIGHTING SYSTEMS IN BUILDINGS - CODE OF PRACTICE |
BS 8899:2016 | Improvement of fire-fighting and evacuation provisions in existing lifts. Code of practice |
BS 5266-1:2011 | Emergency lighting Code of practice for the emergency escape lighting of premises |
BS 6266:2011 | Fire protection for electronic equipment installations. Code of practice |
15/30301742 DC : 0 | BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS |
15/30301829 DC : 0 | BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE |
BS 8524-2:2013 | Active fire curtain barrier assemblies Code of practice for application, installation and maintenance |
11/30203947 DC : 0 | BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE |
16/30331553 DC : 0 | BS 5266-1 - EMERGENCY LIGHTING - PART 1: CODE OF PRACTICE FOR THE EMERGENCY LIGHTING OF PREMISES |
12/30205676 DC : 0 | BS 8524-2 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 2: CODE OF PRACTICE |
16/30314117 DC : 0 | BS 9999 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF BUILDINGS - CODE OF PRACTICE |
BS 8592:2016 | Electric cables. Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables of rated voltage 450/750 V, having low emission of smoke and corrosive gases when affected by fire. Specification |
13/30266935 DC : 0 | BS 7346-8 - COMPONENTS FOR SMOKE CONTROL SYSTEMS - PART 8: CODE OF PRACTICE FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE |
13/30264663 DC : 0 | BS 7346-7 - COMPONENTS FOR SMOKE AND HEAT CONTROL SYSTEMS - PART 7: CODE OF PRACTICE ON FUNCTIONAL RECOMMENDATIONS AND CALCULATION METHODS FOR SMOKE AND HEAT CONTROL SYSTEMS FOR COVERED CAR PARKS |
BS 7346-7:2013 | Components for smoke and heat control systems Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks |
BS 7629-1:2015 | Electric cables. Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire Multicore cables |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS EN 13501-2 : 2007 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES |
BS EN 12101-2:2017 | Smoke and heat control systems Natural smoke and heat exhaust ventilators |
BS EN 50200:2015 | Method of test for resistance to fire of unprotected small cables for use in emergency circuits |
BS EN 1366-9:2008 | Fire resistance tests for service installations Single compartment smoke extraction ducts |
BS 9990:2006 | Code of practice for non-automatic fire-fighting systems in buildings |
BS 7346-7:2006 | Components for smoke and heat control systems Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks |
BS 8491:2008 | Method for assessment of fire integrity of large diameter power cables for use as components for smoke and heat control systems and certain other active fire safety systems |
BS EN 12101-6:2005 | Smoke and heat control systems Specification for pressure differential systems. Kits |
BS EN 13565-1 : 2003 | FIXED FIREFIGHTING SYSTEMS - FOAM SYSTEMS - PART 1: REQUIREMENTS AND TEST METHODS FOR COMPONENTS |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 8434-2(2003) : 2003 | METHODS OF TEST FOR ASSESSMENT OF THE FIRE INTEGRITY OF ELECTRIC CABLES - PART 2: TEST FOR UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS - BS EN 50200 WITH A 930 DEGREE C FLAME AND WITH WATER SPRAY |
BS EN 81-72:2015 | Safety rules for the construction and installation of lifts. Particular applications for passenger and goods passenger lifts Firefighters lifts |
DD CEN/TS 14816:2008 | Fixed firefighting systems. Water spray systems. Design and installation |
BS EN 13565-2:2009 | Fixed firefighting systems. Foam systems Design, construction and maintenance |
ISO 6944:1985 | Fire resistance tests — Ventilation ducts |
BS EN 12101-3:2015 | Smoke and heat control systems Specification for powered smoke and heat control ventilators (Fans) |
BS EN 12101-1 : 2006 | SMOKE AND HEAT CONTROL SYSTEMS - PART 1: SPECIFICATION FOR SMOKE BARRIERS |
BS 476-24:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of ventilation ducts |
BS EN 12416-2:2001 | Fixed firefighting systems. Powder systems Design, construction and maintenance |
BS EN 12101-10:2005 | Smoke and heat control systems Power supplies |
BS EN 12416-1:2001 | Fixed firefighting systems. Powder systems Requirements and test methods for components |
BS 5839-9:2003 | Fire detection and alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems |
BS 7273-4:2007 | Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.