BS EN 15058:2017
Current
The latest, up-to-date edition.
Stationary source emissions. Determination of the mass concentration of carbon monoxide. Standard reference method: non-dispersive infrared spectrometry
Hardcopy , PDF
English
31-01-2017
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Principle
6 Description of the measuring system
7 Performance characteristics of the SRM
8 Suitability of the measuring system for
the measurement task
9 Field operation
10 Ongoing quality control
11 Expression of results
12 Equivalence of an alternative method
13 Measurement report
Annex A (informative) - Validation of the method
in the field
Annex B (informative) - Schematics of non-dispersive
infrared spectrometer
Annex C (informative) - Calculation of the
uncertainty associated with a concentration
expressed on dry gas and at an oxygen
reference concentration
Annex D (informative) - Example of assessment of
compliance of non-dispersive infrared method
for CO with requirements on emission measurements
Annex E (informative) - Example of correction of
data from drift effect
Annex F (informative) - Significant technical changes
Bibliography
Defines the standard reference method (SRM) based on the infra-red (IR) absorption principle. Also includes the sampling and the gas conditioning system, and allows the determination of the carbon monoxide CO in flue gases emitted to the atmosphere from ducts and stacks.
Committee |
EH/2/1
|
DevelopmentNote |
Supersedes 14/30293554 DC. (01/2017)
|
DocumentType |
Standard
|
Pages |
54
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies the standard reference method (SRM) based on the infrared (IR) absorption principle. It includes the sampling and the gas conditioning system, and allows the determination of the carbon monoxide CO in flue gases emitted to the atmosphere from ducts and stacks. This European Standard specifies the characteristics to be determined and the performance criteria to be fulfilled by portable automatedmeasuring systems (P-AMS) using the IR measurement method. It applies for periodic monitoring and for the calibration or control of automated measuring systems (AMS) permanently installed on a stack, for regulatory or other purposes. This European Standard specifies criteria for demonstration of equivalence of an alternative method (AM) to the SRM by application of EN14793:2017 . This European Standard has been validated during field tests on waste incineration, co-incineration and large combustion plants and on a recognized test bench. It has been validated for CO concentrations with sampling periods of 30min in the range of 0mg/m 3 to 400mg/m 3 for large combustion plants and 0mg/m 3 to 740mg/m 3 for waste and co-incineration. Directive 2010/75/EU lays down emission values which are expressed in mg/m 3, on dry basis at a specified value of oxygen and at standard conditions (273K and 101,3kPa). NOTE The characteristics of installations, the conditions during field tests and the values of repeatability and reproducibility in the field are given in AnnexA.
Standards | Relationship |
DIN EN 15058:2006-09 | Identical |
NEN EN 15058 : 2017 | Identical |
UNE-EN 15058:2007 | Identical |
SN EN 15058:2017 | Identical |
NS EN 15058 : 2017 | Identical |
I.S. EN 15058:2017 | Identical |
NBN EN 15058 : 2006 | Identical |
UNI EN 15058 : 2006 | Identical |
NF EN 15058 : 2017 | Identical |
EN 15058:2017 | Identical |
UNE-EN 15058:2017 | Identical |
ISO 14956:2002 | Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty |
ISO 5725-6:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values |
EN 15259:2007 | Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
EN ISO 14956:2002 | Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002) |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
EN 14790:2017 | Stationary source emissions - Determination of the water vapour in ducts - Standard reference method |
EN 15267-4:2017 | Air quality - Certification of automated measuring systems - Part 4: Performance criteria and test procedures for automated measuring systems for periodic measurements of emissions from stationary sources |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
EN 14793:2017 | Stationary source emissions - Demonstration of equivalence of an alternative method with a reference method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.