1 Scope
2 Normative references
3 Definitions
REQUIREMENTS FOR PRESSURIZED ENCLOSURES
4 Enclosures and ducting
5 Temperature limits
6 Safety provisions and safety devices (except for static
pressurization)
7 Safety provisions and safety devices for static
pressurization
8 Supply of protective gas
ADDITIONAL REQUIREMENTS FOR PRESSURIZED ENCLOSURES WITH
CONTAINMENT SYSTEMS
9 Introduction
10 Release conditions
11 Design requirements for the containment system
12 Protective gas and pressurizing technique
13 Ignition capable apparatus
14 Internal hot surfaces
VERIFICATION AND TESTS
15 Type verification and tests
16 Routine tests
MARKING
17 Marking
ANNEXES
Annex A (informative) Ducting of protective gas
Annex B (informative) Infallibility test for a containment
system
Annex C (informative) Function test of surveillance circuits
Annex D (normative) Purging and dilution tests
Specifies the requirements for the construction and testing of pressurized and purged electrical apparatus and "Ex" components forming part of the pressurized apparatus, with type of protection 'p', intended for use in potentially explosive atmospheres of gas vapour and mist.
Committee |
EXL/31
|
DevelopmentNote |
Supersedes BS 5501-3(1977) To be read in conjunction with BS EN 50014 (09/2002)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
EN 50016:2002 | Identical |
NEN EN 50016 : 2002 | Identical |
I.S. EN 50016:2002 | Identical |
NBN EN 50016 : 2003 | Identical |
SN EN 50016 : 2002 | Identical |
NF EN 50016 : 2004 | Identical |
UNE-EN 50016:2003 | Identical |
DEFSTAN 00-101(PT3)/1(2005) : 2005 | DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 3: ELECTRICAL EQUIPMENT AND INSTALLATION |
DEFSTAN 00-101(PT3)/2(2008) : 2008 | DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 3: ELECTRICAL EQUIPMENT AND INSTALLATION |
PD 6686:2006 | Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries |
EEMUA 181 : 1995 | GUIDE TO RISK BASED ASSESSMENTS OF IN-SITU LARGE EX 'E' AND EX 'N' MACHINES |
BS 6739:2009 | Code of practice for instrumentation in process control systems: installation design and practice |
08/30136724 DC : DRAFT MAY 2008 | BS 6739 - CODE OF PRACTICE FOR INSTRUMENTATION IN PROCESS CONTROL SYSTEMS - INSTALLATION DESIGN AND PRACTICE |
BS EN 1532:1997 | Installation and equipment for liquefied natural gas. Ship to shore interface |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
EN 50033 : 1991 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - CAPLIGHTS FOR MINES SUSCEPTIBLE TO FIREDAMP |
EN 50039:1980 | Electrical apparatus for potentially explosive atmospheres - Intrinsically safe electrical systems 'i' |
HD 214 : 200S2 | RECOMMENDED METHOD FOR DETERMINING THE COMPARATIVE TRACKING INDEX OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS |
EN 60034-1:2010/corrigendum Oct. 2010 | ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE |
EN 50020:2002 | Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i' |
EN 50017:1998 | Electrical apparatus for potentially explosive atmospheres - Powder filling "q" |
EN 50019:2000/corrigendum Apr. 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
EN 50018 : 2000 AMD 1 2002 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D" |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
EN 50015:1998 | Electrical apparatus for potentially explosive atmospheres - Oil immersion "o" |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 50028:1987 | Electrical apparatus for potentially explosive atmospheres - Encapsulation 'm' |
EN 50014:1997/A2:1999 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS |
EN 60034-5:2001/A1:2007 | ROTATING ELECTRICAL MACHINES - PART 5: DEGREES OF PROTECTION PROVIDED BY THE INTEGRAL DESIGN OF ROTATING ELECTRICAL MACHINES (IP CODE) - CLASSIFICATION |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.