• Shopping Cart
    There are no items in your cart

BS EN 50329 : 2003

Current

Current

The latest, up-to-date edition.

RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2003

€254.76
Excluding VAT

Introduction
1 General
2 General requirements for a traction transformer
3 Directly-coupled traction transformer
4 Traction converter transformers
5 Auxiliary transformers
6 Traction auto-transformers
Annex A (informative) - Preferred duty classes
Annex B (normative) - Insulation characteristics and test
        values
Annex C (normative) - Determination of losses and of
        equivalent current by means of alternative methods
Annex E (informative) - Evaluation of traction transformer
        behaviour
Annex F (informative) - Information for tenders and orders
Bibliography

Defines specific characteristics of traction transformers as defined in 1.3.1, used in traction substation or along the track for the supply of power to a.c. and d.c. traction systems or to provide power to auxiliary services.

Committee
GEL/9/3
DevelopmentNote
Supersedes BS 7682(1993) & 00/243540 DC Partially supersedes BS EN 60146-1-3 (08/2003) 2003 Edition Re-Issued in October 2010 & incorporates AMD 1 2010. Supersedes 08/30184551 DC. (10/2010)
DocumentType
Standard
Pages
38
PublisherName
British Standards Institution
Status
Current
Supersedes

HD 428.4 : 200S1 THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - DETERMINATION OF THE POWER RATING OF A TRANSFORMER LOADED WITH NON-SINUSODIAL CURRENTS
IEC 60076-7:2005 Power transformers - Part 7: Loading guide for oil-immersed power transformers
R009-002 : 1998 RAILWAY APPLICATIONS - GUIDE FOR THE USE OF THE TERMINOLOGY FOR TESTING PROCEDURES
EN 50122-1:2011/A4:2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK
EN 61000-2-12:2003 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
EN 60076-5:2006 Power transformers - Part 5: Ability to withstand short-circuit
EN 60076-11:2004 Power transformers - Part 11: Dry-type transformers
IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
HD 538.3 : 200S1 THREE-PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 2500 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 3: DETERMINATION OF THE POWER RATING OF A TRANSFORMER LOADED WITH NON-SINUSOIDAL CURRENT
EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
EN 50125-2:2002/corrigendum:2010 RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS
IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
EN 50327 : 2003 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
IEC 60076-1:2011 Power transformers - Part 1: General
EN 50152-1 : 2012 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
EN 50163 : 2004 COR 2013 RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS
IEC 60905:1987 Loading guide for dry-type power transformers
EN 50121-5:2017 Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus
IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
EN 61378-1:2011 Convertor transformers - Part 1: Transformers for industrial applications
EN 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
EN 50328 : 2003 COR 2006 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
IEC 61378-1:2011 Converter transformers - Part 1: Transformers for industrial applications

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.