• Shopping Cart
    There are no items in your cart

BS EN 60099-9:2014

Current

Current

The latest, up-to-date edition.

Surge arresters Metal-oxide surge arresters without gaps for HVDC converter stations

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-09-2014

€348.24
Excluding VAT

1 Scope
2 Normative references
3 Terms and definitions
4 Typical HVDC converter station schemes,
   arrester types, locations and operating voltage
5 Identification and classification
6 Service conditions
7 Requirements
8 General testing procedure
9 Type tests (design tests)
10 Routine tests and acceptance test
11 Test requirements on different types of arresters
Annex A (normative) - Test to verify thermal equivalency
        between complete arrester and arrester section
Annex B (normative) - Determination of the start
        temperature in the thermal recovery test
Annex C (normative) - Mechanical considerations
Annex D (informative) - Different circuit configurations
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Pertains to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit overvoltages in HVDC converter stations of two terminal, multiterminal and back-to-back type up to and including an operating voltage of 1100 kV.

Committee
PEL/37
DocumentType
Standard
Pages
94
PublisherName
British Standards Institution
Status
Current

IEC 60099-9:2014 applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit overvoltages in HVDC converter stations of two terminal, multiterminal and back-to-back type up to and including an operating voltage of 1 100 kV. The standard applies in general to porcelain-housed and polymer-housed type arresters but also to gas-insulated metal enclosed arresters (GIS-arresters) solely used as d.c. bus and d.c. line/cable arresters. Arresters for voltage source converters are not covered. Arresters applied on the a.c. systems at the converter station and subjected to power-frequency voltage of 50 or 60 Hz principally without harmonics are tested as per IEC 60099-4. The arresters on a.c.-filters are tested according to this standard. Keywords: testing of gapless metal-oxide surge arrestors for HVDC converter stations

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.