1 Scope and object
2 Normative references
3 Terms and definitions
4 General conditions for tests
5 Analysis and classification of transmitter performance
6 General testing procedures and precautions
7 Test procedures and reporting
8 Other considerations
9 Test report and documentation
Annex A (informative) - Analysis and classification of the
the instrument performance
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Describes uniform methods of test for the evaluation of the performance of transmitters with pneumatic or electric output signals.
Committee |
GEL/65/2
|
DevelopmentNote |
Supersedes 97/202256 DC and BS 4509(1985) (11/2005) Supersedes 08/30176946 DC. (06/2011)
|
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Covers individually screened and unscreened pairs or quads in cables having less than 20 pairs/10 quads for horizontal floor wiring. The cables may be provided with a common screen over the cable core. These cables are suitable for the various communication systems for which the reference is given in the appropriate detail specification.
Standards | Relationship |
IEC 60770-1:2010 | Identical |
SN EN 60770-1 : 1999 | Identical |
EN 60770-1:2011 | Identical |
NF EN 60770-1 : 2011 | Identical |
DIN EN 60770-1 : 2011 | Identical |
NBN EN 60770-1 : 2011 | Identical |
I.S. EN 60770-1:2011 | Identical |
IEC 60381-1:1982 | Analogue signals for process control systems. Part 1: Direct current signals |
EN 61298-1:2008 | PROCESS MEASUREMENT AND CONTROL DEVICES - GENERAL METHODS AND PROCEDURES FOR EVALUATING PERFORMANCE - PART 1: GENERAL CONSIDERATIONS |
IEC 61298-1:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 1: General considerations |
EN 61298-3:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 3: Tests for the effects of influence quantities |
IEC 61298-2:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 2: Tests under reference conditions |
EN 60382 : 93 AC 94 | ANALOGUE PNEUMATIC SIGNAL FOR PROCESS CONTROL SYSTEMS |
EN 61298-2:2008 | PROCESS MEASUREMENT AND CONTROL DEVICES - GENERAL METHODS AND PROCEDURES FOR EVALUATING PERFORMANCE - PART 2: TESTS UNDER REFERENCE CONDITIONS |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61187:1993 | Electrical and electronic measuring equipment - Documentation |
EN 61298-4:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 4: Evaluation report content |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 60770-3:2014 | Transmitters for use in industrial-process control systems - Part 3: Methods for performance evaluation of intelligent transmitters |
HD 452.1 : 200S1 | ANALOGUE SIGNALS FOR PROCESS CONTROL SYSTEMS - DIRECT CURRENT SIGNALS |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60382:1991 | Analogue pneumatic signal for process control systems |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61298-3:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 3: Tests for the effects of influence quantities |
EN 61000-4-12:2017 | Electromagnetic compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 61032:1998 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 61298-4:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 4: Evaluation report content |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60381-2:1978 | Analogue signals for process control systems. Part 2: Direct voltage signals |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 61010-1:2010 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
EN 61000-4-16:2016 | Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 60770-3:2014 | Transmitters for use in industrial-process control systems - Part 3: Methods for performance evaluation of intelligent transmitters |
IEC 60050-300:2001 | International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument |
EN 61000-4-10:2017 | Electromagnetic compatibility (EMC) - Part 4-10: Testing and measurement techniques - Damped oscillatory magnetic field immunity test |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.