1 General
1.1 Scope
1.2 Normative references
1.3 Information to be given in a detail specification
1.3.1 General
1.3.2 Outline drawing and dimensions
1.3.3 Mounting
1.3.4 Ratings and characteristics
1.3.5 Marking
1.4 Terms and definitions
1.5 Marking
1.5.1 IEC 60939-1 with the following details:
1.5.2 The filter shall be clearly marked with the
information in 1.5.1 a), b), c) and d), and also e)
if this is not implied by b)
1.5.3 The package containing the filter(s) shall be
clearly marked with all the information listed
in 1.5.1
1.5.4 Any additional marking shall be so applied that no
confusion can arise
2 Preferred ratings and characteristics
2.1 Preferred characteristics
2.1.1 General
2.1.2 Preferred climatic categories
2.2 Preferred values of ratings
2.2.1 Rated voltage (U[R])
2.2.2 Category voltage (U[C])
2.2.3 Rated temperature
2.2.4 Passive flammability
3 Quality assessment procedures
3.1 Primary stage of manufacture
3.2 Structurally similar filters
3.3 Certified records of released lots
3.4 Approval testing
3.4.1 Safety tests only approval
3.4.2 Qualification approval
3.4.3 Sampling
3.4.4 Tests
3.5 Quality conformance inspection
3.5.1 General
3.5.2 Formation of inspection lots
3.5.3 Test schedule
3.5.4 Delayed delivery
4 Test and measurement procedures
4.1 Earth inductors incorporated in filters
4.2 Capacitance and tan delta measurements
4.3 Visual examination and check of dimensions
4.3.1 General
4.3.2 Creepage distances and clearances
4.4 Voltage proof
4.4.1 Test circuit for d.c. tests
4.4.2 Applied voltage
4.4.3 Requirements
4.5 Insulation resistance
4.5.1 Temperature correction
4.5.2 Requirements
4.6 DC line resistance or voltage drop at rated current
4.6.1 DC line resistance
4.6.2 Voltage drop at rated current
4.7 Insertion loss
4.8 Discharge resistance
4.9 Robustness of terminations
4.10 Resistance to soldering heat
4.10.1 Test conditions
4.10.2 Intermediate inspection, measurements and
requirements
4.11 Solderability
4.11.1 Test conditions
4.11.2 Requirements
4.12 Rapid change of temperature
4.12.1 Intermediate inspection
4.13 Vibration
4.13.1 Test conditions
4.13.2 Intermediate inspection
4.14 Bump
4.14.1 Test conditions
4.14.2 Intermediate inspection, measurements and
requirements
4.15 Shock
4.15.1 Test conditions
4.15.2 Intermediate inspection, measurements and
requirements
4.16 Container sealing
4.16.1 Test conditions
4.16.2 Requirements
4.17 Climatic sequence
4.17.1 Initial measurements
4.17.2 Dry heat
4.17.3 Damp heat, cyclic, first cycle
4.17.4 Cold
4.17.5 Low air pressure
4.17.6 Damp heat, cyclic, remaining cycles
4.17.7 Final inspection, measurements and requirements
4.18 Damp heat, steady state
4.18.1 Test conditions
4.18.2 Final inspection, measurements and requirements
4.19 Temperature rise
4.19.1 Test method
4.19.2 Requirements
4.20 Impulse voltage
4.20.1 Initial measurements
4.20.2 Test conditions
4.20.3 Requirements
4.21 Endurance
4.21.1 Test conditions - current test
4.21.2 Test conditions - voltage test, terminations/case
4.21.3 Test conditions - voltage test between terminations
4.21.4 Test conditions - combined voltage/current tests
4.21.5 Final inspection, measurements and requirements
4.22 Charge and discharge
4.22.1 Initial measurements
4.22.2 Test conditions
4.22.3 Final measurements and requirements
4.23 Passive flammability
4.20.2 Test conditions
4.20.3 Requirements
4.24 Current overload
4.25 Solvent resistance of the marking
4.26 Component solvent resistance
4.27 Active flammability
Annex A (normative) Test schedule for qualification approval -
Assessment level D/DZ
Annex B (normative) Test schedule for safety requirements only
Annex C (normative) Circuit for the impulse voltage test
Annex D (normative) Circuit for the endurance test
Annex E (normative) Declaration of design
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Figures
Tables
Applicable to passive filter units for electromagnetic interference suppression which fall within the scope of the Generic Specification IEC 60939-1.
Committee |
W/-
|
DevelopmentNote |
Supersedes BS EN 133200 & 03/101948 DC. (09/2005)
|
DocumentType |
Standard
|
Pages |
50
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
Standards | Relationship |
IEC 60939-2:2005/COR1:2005 | Identical |
EN 62011-3-1:2003 | Identical |
IEC 60939-2:2005 | Identical |
NBN EN 60939-2 : 2006 | Identical |
DIN EN 60939-2 : 2006 | Identical |
NF EN 60939-2 : 2005 | Identical |
EN 60939-2:2005 | Identical |
EN 60939-1:2010 | PASSIVE FILTER UNITS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION - PART 1: GENERIC SPECIFICATION |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
EN 60938-1:1999/A1:2007 | FIXED INDUCTORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION - PART 1: GENERIC SPECIFICATION |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60939-1:2010 | Passive filter units for electromagnetic interference suppression - Part 1: Generic specification |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
IEC 60384-9:2015 | Fixed capacitors for use in electronic equipment - Part 9: Sectional specification: Fixed capacitors of ceramic dielectric, Class 2 |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60938-1:1999+AMD1:2006 CSV | Fixed inductors for electromagnetic interference suppression - Part 1: Generic specification |
IEC 60940:2015 | Guidance information on the application of capacitors, resistors, inductors and complete filter units for electromagnetic interference suppression |
EN 60068-2-17:1994 | Environmental testing - Part 2: Tests - Test Q: Sealing |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 60062:2016 | Marking codes for resistors and capacitors |
EN 60062:2016/AC:2016-12 | MARKING CODES FOR RESISTORS AND CAPACITORS (IEC 60062:2016/COR1:2016) |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.