• There are no items in your cart

BS EN 61000-4-1:2007

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Electromagnetic compatibility (EMC) Testing and measurement techniques. Overview of IEC 61000-4 series

Available format(s)

Hardcopy , PDF

Withdrawn date

31-07-2016

Language(s)

English

Published date

30-03-2007

€156.59
Excluding VAT

INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 General
5 Structure of the IEC 61000-4 series standards
6 Selection of tests
7 Test report
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications

Covers testing and measuring techniques for electric and electronic equipment (apparatus and systems) in its electromagnetic environment. It also gives applicability assistance to the technical committees of IEC or other bodies, users and manufacturers of electrical and electronic equipment on EMC standards within the IEC 61000-4 series on testing and measurement techniques and provides general recommendations concerning the choice of relevant tests.

Committee
GEL/210
DevelopmentNote
Supersedes 03/107918 DC. (03/2007)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Withdrawn
Supersedes

The object of this part of IEC 61000 is to give applicability assistance to the technical committees of IEC or other bodies, users and manufacturers of electrical and electronic equipment on EMC standards within the IEC 61000-4 series on testing and measurement techniques and to provide general recommendations concerning the choice of relevant tests. This standard has the status of a basic EMC publication in accordance with IEC Guide 107.

Standards Relationship
EN 61000-4-1:2007 Identical
NF EN 61000-4-1 : 2007 Identical
I.S. EN 61000-4-1:2007 Identical
IEC 61000-4-1:2006 Identical
UNE-EN 61000-4-1:2007 Identical
DIN EN 61000-4-1 : 2007 Identical
SN EN 61000-4-1 : 2000 Identical

03/106314 DC : 0 BS PQIR - CRANES - CONDITION MONITORING - PART 1: SPECIFICATION FOR DATA LOGGING EQUIPMENT
BS DD8483(2008) : 2008 CRANES - CONDITION MONITORING - SPECIFICATION FOR DATA LOGGING EQUIPMENT
BS EN 60870-2-1:1996 Telecontrol equipment and systems. Operating conditions Power supply and electromagnetic compatibility

EN 61000-4-30:2015/AC:2017-01 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016)
EN 61000-4-28:2000/A2:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-28: TESTING AND MEASUREMENT TECHNIQUES - VARIATION OF POWER FREQUENCY, IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE
EN 61000-4-21:2011 Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods
IEC TR 61000-1-1:1992 Electromagnetic compatibility (EMC) - Part 1: General - Section 1: Application and interpretation of fundamental definitions and terms
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
EN 61000-4-9:2016 Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
EN 61000-3-11:2000 Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
EN 61000-3-3:2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013)
IEC 61000-4-25:2001+AMD1:2012 CSV Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems
EN 61000-4-23:2000 Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-3-12:2011 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
EN 61000-4-14:1999/A2:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-14: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE FLUCTUATION IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-17:1999+AMD1:2001+AMD2:2008 CSV Electromagnetic compatibility (EMC) - Part 4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
EN 61000-4-7:2002/A1:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-7: TESTING AND MEASUREMENT TECHNIQUES - GENERAL GUIDE ON HARMONICS AND INTERHARMONICS MEASUREMENTS AND INSTRUMENTATION, FOR POWER SUPPLY SYSTEMS AND EQUIPMENT CONNECTED THERETO (IEC 61000-4-7:2002/A1:2008)
IEC 61000-4-33:2005 Electromagnetic compatibility (EMC) - Part 4-33: Testing and measurement techniques - Measurement methods for high-power transient parameters
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
IEC 61000-4-28:1999+AMD1:2001+AMD2:2009 CSV Electromagnetic compatibility (EMC) - Part 4-28: Testing and measurement techniques - Variation of power frequency, immunity test for equipment with input current not exceeding 16 A per phase
IEC 61000-4-24:2015 Electromagnetic compatibility (EMC) - Part 4-24: Testing and measurement techniques - Test methods for protective devices for HEMP conducted disturbance
IEC 61000-4-27:2000+AMD1:2009 CSV Electromagnetic compatibility (EMC) - Part 4-27: Testing and measurement techniques - Unbalance, immunity test for equipment with input current not exceeding 16 A per phase
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-15:2010 Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications
IEC 61000-4-20:2010 Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides
EN 61000-4-12:2017 Electromagnetic compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC TS 61000-3-4:1998 Electromagnetic compatibility (EMC) - Part 3-4: Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 61000-3-12:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011)
IEC 61000-4-14:1999+AMD1:2001+AMD2:2009 CSV Electromagnetic compatibility (EMC) - Part 4-14: Testing and measurement techniques - Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase
IEC 61000-4-7:2002+AMD1:2008 CSV Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
IEC TR 61000-4-32:2002 Electromagnetic compatibility (EMC) - Part 4-32: Testing and measurement techniques - High-altitude electromagnetic pulse (HEMP) simulator compendium
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
IEC 61000-4-23:2016 Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances
EN 61000-4-24:1997 Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 24: Test methods for protective devices for HEMP conducted disturbance
EN 61000-4-16:2016 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
EN 61000-4-27:2000/A1:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-27: TESTING AND MEASUREMENT TECHNIQUES - UNBALANCE, IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE
IEC 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
EN 61000-4-17:1999/A2:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-17: TESTING AND MEASUREMENT TECHNIQUES - RIPPLE ON D.C. INPUT POWER PORT IMMUNITY TEST
EN 61000-4-13:2002/A2:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015)
IEC 61000-4-18:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test
IEC 61000-4-21:2011 Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
EN 61000-4-15:2011 Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications
IEC 61000-4-34:2005+AMD1:2009 CSV Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase
EN 61000-4-20:2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
EN 61000-4-10:2017 Electromagnetic compatibility (EMC) - Part 4-10: Testing and measurement techniques - Damped oscillatory magnetic field immunity test
EN 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
EN 61000-4-25 : 2002 AMD 1 2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-25: TESTING AND MEASUREMENT TECHNIQUES - HEMP IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS (IEC 61000-4-25:2001/A1:2012)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.