BS EN ISO 8230-3:2008
Current
The latest, up-to-date edition.
Safety requirements for dry-cleaning machines Machines using combustible solvents
Hardcopy , PDF
English
31-07-2009
Committee |
TCI/33
|
DevelopmentNote |
Together with BS EN ISO 8230-1 and BS EN ISO 8230-2 it supersedes BS EN ISO 8230. (07/2009) Reviewed and confirmed by BSI, September 2016. (08/2016)
|
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of ISO8230 specifies safety requirements for dry-cleaning machines that use a combustible solvent (CS), as defined in ISO8230-1, as their cleaning medium.
It is applicable to such dry-cleaning machines, within the scope of ISO8230-1, when they are used as intended and under conditions of misuse that are reasonably foreseeable by the manufacturer.
This part of ISO8230, in conjunction with ISO8230-1, deals with all significant hazards, significant hazardous situations and significant hazardous events that have been identified as being significant to the types of machines covered by this part of ISO8230 and which require specific action by the designer or manufacturer to eliminate or reduce the risk.
It deals with the following significant hazards specific to the use of CS:
-
hazards related to the entire dry-cleaning machine (electrical hazards, explosion hazards);
-
hazards relating to the machine (combustible solvent emission, explosion hazards during the cleaning phase, explosion hazards during the drying phase);
-
hazards relating to the distilling equipment (combustible solvent emission, explosion hazards).
This part of ISO8230 applies to machines manufactured after the date of its issue.
Standards | Relationship |
ISO 8230-3:2008 | Identical |
EN ISO 8230-3:2008 | Identical |
EN 50037 : 1987 | LOW VOLTAGE SWITCHGEAR & CONTROLGEAR FOR INDUSTRIAL USE - INDUCTIVE PROXIMITY SWITCHES, FORM C FOR ALTERNATING CURRENT, 2 TERMINALS |
EN 1127-1:2011 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
EN 50033 : 1991 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - CAPLIGHTS FOR MINES SUSCEPTIBLE TO FIREDAMP |
ISO 2719:2016 | Determination of flash point — Pensky-Martens closed cup method |
EN 50104:2010 | Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods |
EN 14756:2006 | Determination of the limiting oxygen concentration (LOC) for flammable gases and vapours |
EN 50039:1980 | Electrical apparatus for potentially explosive atmospheres - Intrinsically safe electrical systems 'i' |
EN 50026 : 1987 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR FOR INDUSTRIAL USE - INDUCTIVE PROXIMITY SWITCHES - FORM D FOR DIRECT CURRENT, 3 OR 4 TERMINALS |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
EN 50020:2002 | Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i' |
EN 13463-1:2009 | Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements |
EN 61779-4:2000 | Electrical apparatus for the detection and measurement of flammable gases - Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100 % lower explosive limit |
IEC 60204-1:2016 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
EN 50035 : 1978 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR FOR INDUSTRIAL USE - MOUNTING RAILS - G-PROFILE FOR THE FIXING OF TERMINAL BLOCKS |
EN 50017:1998 | Electrical apparatus for potentially explosive atmospheres - Powder filling "q" |
EN 50019:2000/corrigendum Apr. 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
EN 50025 : 1987 | LOW VOLTAGE SWITCHGEAR FOR INDUSTRIAL USE - INDUCTIVE PROXIMITY SWITCHES - FORM C, FOR DIRECT CURRENT, 3 OR 4 TERMINALS |
EN 50032 : 1980 | LOW VOLTAGE SWITCHGEAR & CONTROLGEAR FOR INDUSTRIAL USE - INDUCTIVE PROXIMITY SWITCHES - DEFINITIONS, CLASSIFICATION & DESIGNATION |
EN 50018 : 2000 AMD 1 2002 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D" |
ISO 8230-1:2008 | Safety requirements for dry-cleaning machines Part 1: Common safety requirements |
EN 50021 : 99 COR 2000 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - TYPE OF PROTECTION "N" |
EN 50038 : 1987 | LOW VOLTAGE SWITCHGEAR & CONTROLGEAR FOR INDUSTRIAL USE - INDUCTIVE PROXIMITY SWITCHES, FORM D FOR ALTERNATING CURRENT, 2 TERMINALS |
EN 50036 : 1987 | LOW VOLTAGE SWITCHGEAR & CONTROLGEAR FOR INDUSTRIAL USE - INDUCTIVE PROXIMITY SWITCHES, FORM A, ALTERNATING CURRENT, 2 TERMINALS |
ISO 12100-2:2003 | Safety of machinery Basic concepts, general principles for design Part 2: Technical principles |
EN 61779-1 : 2000 AMD 11 2004 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
ISO 12100-1:2003 | Safety of machinery Basic concepts, general principles for design Part 1: Basic terminology, methodology |
EN 50022 : 1977 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR FOR INDUSTRIAL USE - MOUNTING RAILS - TOP HAT RAILS 35mm WIDE FOR SNAP-ON MOUNTING OF EQUIPMENT |
EN 50015:1998 | Electrical apparatus for potentially explosive atmospheres - Oil immersion "o" |
EN 50016:2002 | Electrical apparatus for potentially explosive atmospheres - Pressurized apparatus "p" |
1998/37/EC : 1998 | DIRECTIVE 98/37/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 22 JUNE 1998 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO MACHINERY |
EN 50034 : LATEST | |
EN 50028:1987 | Electrical apparatus for potentially explosive atmospheres - Encapsulation 'm' |
EN 50023 : 1977 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR FOR INDUSTRIAL USE - MOUNTING RAILS - TOP HAT RAILS 75mm WIDE FOR SNAP-ON MOUNTING OF EQUIPMENT |
EN 50024 : 1978 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR FOR INDUSTRIAL USE - MOUNTING RAILS - C-PROFILE AND ACCESSORIES FOR THE MOUNTING OF EQUIPMENT |
EN 50030 : LATEST | |
EN 50027 : 1979 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR FOR INDUSTRIAL USE - TERMINAL APERTURE SIZES FOR UNPREPARED ROUND COPPER CONDUCTORS |