CEI EN 60669-2-5 : 1ED 2017
Current
The latest, up-to-date edition.
SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 2-5: PARTICULAR REQUIREMENTS - SWITCHES AND RELATED ACCESSORIES FOR USE IN HOME AND BUILDING ELECTRONIC SYSTEMS (HBES)
01-03-2017
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Rating
7 Classification
8 Marking
9 Checking of dimensions
10 Protection against electric shock
11 Provision for earthing
12 Terminals
13 Constructional requirements
14 Mechanism
15 Resistance to ageing, protection provided by enclosures
of switches, and resistance to humidity
16 Insulation resistance and electric strength
17 Temperature rise
18 Making and breaking capacity
19 Normal operation
20 Mechanical strength
21 Resistance to heat
22 Screws, current-carrying parts and connections
23 Creepage distances, clearances and distances through
sealing compound
24 Resistance of insulating material to abnormal heat, to
fire and to tracking
25 Resistance to rusting
26 EMC requirements
101 Abnormal conditions
102 Components
Annex A (normative) - Survey of specimens needed for tests
Annex B (normative) - Additional requirements for switches
having facilities for the outlet and retention of
flexible cables
Annex C (informative) - Examples of types of electronic
switches and their functions
Annex AA (normative) - Measurement of clearances and
creepage distances
Annex BB (informative) - Test set-ups
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZB (informative) - A-deviations
Annex ZZA (informative) - Relationship between this European
standard and the essential requirements of Directive
2014/30/EU [2014 OJ L96] aimed to be covered
Annex ZZB (informative) - Relationship between this European
standard and the safety objectives of Directive
2014/35/EU [2014 OJ L96] aimed to be covered
Annex ZZC (informative) - Relationship between this European
standard and the essential requirements of Directive
2014/53/EU [2014 OJ L153] aimed to be covered
This Standard applies to non-automatic switchgear (switches) and related accessories for use in electronic systems for the home and building (HBES), with an operating voltage not exceeding 250 V in alternating current, and a rated current not exceeding 16 A, intended for installations in fixed electrical installations, both indoor and outdoor, and installations in associated peripheral electronic units.
| Committee |
CT 23
|
| DevelopmentNote |
Classificazione CEI 23-134. Supersedes CEI EN 50428 which remains current and will be withdrawn on 31-08-2020. To be read in conjunction with CEI EN 60669-1 & CEI EN 60669-2-1. (03/2017) Italian translation of 1ED 2017 Issued on 01/03/2017. (04/2017)
|
| DocumentType |
Standard
|
| PublisherName |
Comitato Elettrotecnico Italiano
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| IEC 60669-2-5:2013 | Identical |
| EN 60669-2-5:2016 | Identical |
| IEC 60670-1:2015 | Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 1: General requirements |
| EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
| IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
| IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
| EN 61000-3-3:2013 | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current |
| HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
| IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
| CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
| IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
| IEC 60669-2-1:2002+AMD1:2008+AMD2:2015 CSV | Switches for household and similar fixed electrical installations -Part 2-1: Particular requirements - Electronic switches |
| EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
| IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
| IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
| CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
| EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
| EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
| IEC 60715:2017 | Dimensions of low-voltage switchgear and controlgear - Standardized mounting on rails for mechanical support of switchgear, controlgear and accessories |
| EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
| IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
| EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
| IEC 61000-4-20:2010 | Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides |
| IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
| IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
| EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
| IEC 60669-1:2017 | Switches for household and similar fixed-electrical installations - Part 1: General requirements |
| IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
| IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
| EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
| EN 61058-1:2002/A2:2008 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
| IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
| EN 61000-4-4:2012 | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
| EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
| EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
| EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
| IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
| EN 60670-1:2005/A1:2013 | BOXES AND ENCLOSURES FOR ELECTRICAL ACCESSORIES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS (IEC 60670-1:2002/A1:2011, MODIFIED) |
| IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
| EN 60664-3:2017 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
| EN 61000-4-20:2010 | Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides |
| IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
| EN 60990:2016 | Methods of measurement of touch current and protective conductor current |