CSA C22.2 NO. 60947-5-2:14 (R2019)
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Low-voltage switchgear and controlgear - Part 5-2: Control circuit devices and switching elements - Proximity switches (Bi-national standard, with UL 60947-5-2)
Hardcopy , PDF
01-01-2022
English, French
01-01-2014
Preface
NATIONAL DIFFERENCES
FOREWORD
1 General
2 Definitions
3 Classification
4 Characteristics
5 Product information
6 Normal service, mounting and transport conditions
7 Constructional and performance requirements
8 Tests
Annex A (normative) - Specification sheets
Annex B (normative) - Class II PROXIMITY SWITCHES insulated
by ENCAPSULATION - Requirements and tests
Annex C (normative) - Additional requirements for PROXIMITY
SWITCHES with integrally connected cables
Annex D (normative) - Integral connectors for plug-in
PROXIMITY SWITCHES
Annex E (normative) - Additional requirements for PROXIMITY
SWITCHES suitable for use in strong magnetic fields
Annex F (informative) - Symbols for PROXIMITY SWITCHES
Annex 101.DVA - Additional requirements for PROXIMITY
SWITCHES with integrally connected
cables (normative)
Annex 101.DVB - National Standard References (normative)
Pertains to INDUCTIVE and CAPACITIVE PROXIMITY SWITCHES that sense the presence of metallic and/or non-metallic objects, ULTRASONIC PROXIMITY SWITCHES that sense the presence of sound reflecting objects, PHOTOELECTRIC PROXIMITY SWITCHES that sense the presence of objects and NON-MECHANICAL MAGNETIC PROXIMITY SWITCHES that sense the presence of objects with a MAGNETIC FIELD.
DevelopmentNote |
Also numbered as UL 60947-5-2. (04/2014)
|
DocumentType |
Standard
|
ISBN |
978-1-77139-292-1
|
Pages |
144
|
ProductNote |
This standard also refers to CEI 60364, CEI 60947-5-1+A1, CEI 60947-5-1+A2, CEI 61000-3-2+A1, CEI 61000-3-3+A1, CEI 61000-4-2+A1(1998), CEI 61000-4-2+A2(2000), CEI 61000-4-3+A1, CEI 61000-4-4+A1, CEI 61000-4-4+A2, CEI 61000-4-5+A1, CEI 61000-4-6+A1(2000), CEI 61000-4-8+A1, CEI 61000-4-11+A1,
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
SupersededBy |
Preface This is the harmonized CSA Group and UL standard for Low-Voltage Switchgear and Controlgear - Part 5-2: Control Circuit Devices and Switching Elements - Proximity Switches. It is the first edition of CAN/CSA-C22.2 No. 60947-5-2, and the third edition of UL 60947-5-2. This standard is based on IEC 60947-5-2, Edition 2.2, which is based on the second edition (1997), and its amendment 1 (1999) and its amendment 2 (2003). This standard has been approved as a National Standard of Canada by the Standards Council of Canada (SCC). Scope and object This part of IEC 60947 applies to INDUCTIVE and CAPACITIVE PROXIMITY SWITCHES that sense the presence of metallic and/or non-metallic objects, ULTRASONIC PROXIMITY SWITCHES that sense the presence of sound reflecting objects, PHOTOELECTRIC PROXIMITY SWITCHES that sense the presence of objects and NON-MECHANICAL MAGNETIC PROXIMITY SWITCHES that sense the presence of objects with a MAGNETIC FIELD. These PROXIMITY SWITCHES are self-contained, have SEMICONDUCTOR SWITCHING ELEMENTS(S) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz a.c. or 300 V d.c. This Standard is not intended to cover PROXIMITY SWITCHES with analogue outputs. The object of this standard is to state for PROXIMITY SWITCHES: - definitions; - classification; - characteristics; - product information; - normal service, mounting and transport conditions; - constructional and performance requirements; - tests to verify rated characteristics. - 1.1DV.1 DR Modification of 1.1 by adding 1.1DV.1.1 - 1.1DV.1.2: 1.1DV.1.1 This equipment is for use in ordinary locations in accordance with Annex 101.DVB, Reference No. 1. In Canada, general requirements applicable to this equipment are provided in Reference No. 7 of Table 101.DVB. 1.1DV.1.2 These requirements cover electronic PROXIMITY SWITCHES for use on industrial machinery or mass-production industrial equipment as defined by Annex 101.DVB, Reference No. 4. 1.1DV.2 D1 Modification of 1.1 by adding the following: Equipment requirements are intended for use in an ambient temperature of 0 to 40 C unless specified otherwise.
IEC 61020-5-1:1991 | Electromechanical switches for use in electronic equipment - Part 5: Sectional specification for pushbutton switches - Section 1: Blank detail specification |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
CSA C22.2 NO. 60947-5-1:14 (R2019) | Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit devices (Bi-national standard, with UL 60947-5-1) |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
UL 1097:6ED 2012-02-01 | Double Insulation Systems for Use in Electrical Equipment |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
NFPA 79 : 2015 | ELECTRICAL STANDARD FOR INDUSTRIAL MACHINERY |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
CSA C22.2 No. 0.2 : 2016 | INSULATION COORDINATION |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CAN/CSA-C22.2 NO. 60947-1-13 (R2018) | Low-voltage switchgear and controlgear - Part 1: General rules (Tri-national standard, with UL 60947-1 and NMX-J-515-ANCE) |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
ISO 630:1995 | Structural steels Plates, wide flats, bars, sections and profiles |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
CSA C22.2 No. 14 : 2013 | INDUSTRIAL CONTROL EQUIPMENT |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.