CSA E60079.14 : 2002
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL INSTALLATIONS IN EXPLOSIVE GAS ATMOSPHERES (OTHER THAN MINES)
Hardcopy , PDF
18-06-2004
English
01-01-2002
FOREWORD
INTRODUCTION
Clause
1 Scope and object
2 Normative references
3 Definitions and terms
4 General
4.1 General requirements
4.2 Documentation
5 Selection of electrical apparatus (excluding cables
and conduits)
5.1 Specific information
5.2 Selection according to zones
5.3 Selection according to the ignition temperature
of the gas or vapour
5.4 Selection according to apparatus grouping
5.5 External influences
6 Protection from dangerous (incendive) sparking
6.1 Danger from live parts
6.2 Danger from exposed and extraneous conductive
parts
6.3 Potential equalization
6.4 Static electricity
6.5 Lightning protection
6.6 Electromagnetic radiation
6.7 Cathodically protected metallic parts
7 Electrical protection
8 Emergency switch-off and electrical isolation
8.1 Emergency switch-off
8.2 Electrical isolation
9 Wiring systems
9.1 General
9.2 Cable systems for zone 0
9.3 Cable systems for zones 1 and 2
9.4 Conduit systems
10 Additional requirements for type of protection "d" -
Flameproof enclosures
10.1 Solid obstacles
10.2 Protection of flameproof joints
10.3 Cable entry systems
10.4 Motors supplied at varying frequency and voltage
10.5 Conduit systems
Clause
11 Additional requirements for type of protection "e" -
Increased safety
11.1 Degree of protection of enclosures (IEC 34-5 and
IEC 529)
11.2 Cage induction motors-Thermal protection in
operation
11.3 Wiring systems
11.4 Resistance heating devices-
12 Additional requirements for type of protection "i" -
Intrinsic safety
12.1 Introduction
12.2 Installations for zones 1 and 2
12.3 Installations for zone 0
13 Additional requirements for type of protection "p" -
Pressurized apparatus
13.1 Ducting
13.2 Action to betaken on failure of pressurization
13.3 Multiple pressurized enclosures with a common
safety device
13.4 Purging
14 Additional requirements for apparatus for use in
zone 2
14.1 Degree of protection of enclosures (IEC 34-5
and IEC 529)
14.2 Energy-limited apparatus and circuits
14.3 Wiring systems
14.4 Motors supplied at varying frequency and voltage
Annexes
A Verification of intrinsically safe circuits with more
than one associated apparatus with linear
current/voltage characteristics
B Methods of determining the maximum system voltages and
currents in intrinsically safe circuits with more than
one associated apparatus with linear current/voltage
characteristics
Contains the specific requirements for the design, selection and erection of electrical installations in explosive gas atmospheres.
DocumentType |
Standard
|
Pages |
92
|
PublisherName |
Canadian Standards Association
|
Status |
Withdrawn
|
Standards | Relationship |
IEC 60079-14:2013 | Similar to |
CSA PLUS 2203 : 2001 | HAZARDOUS LOCATIONS - GUIDE FOR THE DESIGN, TESTING, CONSTRUCTION, AND INSTALLATION OF EQUIPMENT IN EXPLOSIVE ATMOSPHERES |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
IEC 60079-10:2002 | Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60079-17:2013 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
IEC 60332-1:1993 | Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable |
IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
IEC 60614-2-5:1992 | Specifications for conduits for electrical installations - Part 2: Particular specifications for conduits - Section 5: Flexible conduits |
IEC 60079-5:2015 RLV | Explosive atmospheres - Part 5: Equipment protection by powder filling "q" |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60755:2017 | General safety requirements for residual current operated protective devices |
IEC 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.