EN 14637:2007
Current
The latest, up-to-date edition.
Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance
07-11-2007
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviated term
4 Classification
4.1 Coding system
4.2 Category of use (first digit)
4.3 Durability (second digit)
4.4 Door type (third digit)
4.5 Suitability for use on fire/smoke door assemblies
(fourth digit)
4.6 Safety (fifth digit)
4.7 Corrosion resistance (sixth digit)
4.8 Example of classification
5 Requirements and test methods for components of a
hold-open system
5.1 General
5.2 Fire detectors
5.2.1 Smoke detectors
5.2.2 Heat detectors
5.2.3 Resetting the detectors
5.3 Power supply units
5.3.1 All power supply units
5.3.2 For power supply units with stand-by
parallel operation
5.4 Control units
5.4.1 General
5.4.2 Control units in stand-alone hold-open systems
(single-line systems)
5.4.3 Control units in fire detection and fire alarm
systems (multi-line systems)
5.5 Hold-open devices
5.5.1 General
5.5.2 Hold-open devices for swing doors
5.5.3 Hold-open devices for sliding doors, lifting doors,
industrial doors and roller shutters
5.5.4 Automatic door operators
5.5.5 Low energy/power assisted swing door
operators
5.5.6 Free-swing door closers
5.6 Auxiliary equipment
5.6.1 Manual control push-buttons and switches
5.6.2 Presence sensors (electro-sensitive protective
equipment)
5.6.3 Door position sensors
5.6.4 Remote indicating devices
5.6.5 Manual reset
6 Requirements for the hold-open system
6.1 Design and performance
6.2 Product information
6.2.1 General
6.2.2 For installation and maintenance
6.2.3 For initial hold-open system test
6.3 Requirements not covered under Clause 5
6.4 Electromagnetic compatibility (EMC)
6.5 Additional design requirements for connection of
components to fire alarm systems
6.6 Electrical safety
6.7 Durability
6.8 Environmental behaviour
6.8.1 Dry heat
6.8.2 Cold
6.8.3 Damp heat, steady state (operational)
6.8.4 Corrosion
6.8.5 Vibration
6.9 Supply voltage variations
7 System tests
7.1 General
7.2 Test apparatus
7.3 Theoretical analysis
7.4 Test methods
7.4.1 General
7.4.2 Design verification
7.4.3 Performance tests
7.4.4 Check of switching device capabilities of
the control unit
7.4.5 Short-circuit test
7.4.6 Electrical safety tests
7.4.7 Electromagnetic compatibility (EMC) tests
7.4.8 Environmental tests
7.4.9 Corrosion test
7.4.10 Vibration test, sinusoidal (operational)
7.4.11 Vibration test, sinusoidal (endurance)
8 Marking
8.1 Components
8.2 Hold-open system
Annex A (informative) - Recommendations for planning and
design of the hold-open system
A.1 General
A.2 Restrictions
A.3 Detectors
A.3.1 Selection of detector type
A.3.2 Positioning and number of detectors
A.4 Selection of hold-open device
A.4.1 General
A.4.2 Swing doors
A.4.3 Sliding doors
A.4.4 Roller shutter and lifting doors
A.4.5 Automatic doors
A.5 Manual release and manual control
A.5.1 General
A.5.2 Location of switch/push-button
A.6 Interconnecting cables
A.7 Guidance on competence and responsibilities
for individual installations in individual
buildings
A.7.1 Planning
A.7.2 Installation
Annex B (informative) - Recommendations for installation and
fixing of the hold-open system
Annex C (informative) - Recommendations for acceptance
inspection of the hold-open system
Annex D (informative) - Acceptance inspection report form
Annex E (informative) - Recommendations for usage and
maintenance of the hold-open system
E.1 Usage of installations
E.1.1 General
E.1.2 Periodic inspection
E.2 Routine site inspection report form
Annex F (informative) - Evaluation of conformity
F.1 General
F.1.1 Introduction
F.1.2 Initial type test
F.1.3 Characteristics
F.1.4 Use of historical data
F.1.5 Treatment of calculated values and design
F.1.6 Sampling, testing and conformity criteria
F.2 Factory production control (FPC)
F.2.1 General
F.2.2 FPC requirements for all manufacturers
F.3 Further testing of sample systems
F.3.1 Periodic testing
F.3.2 Yearly testing
F.3.3 Manufacturer-specific FPC system requirements
Annex G (informative) - Type test report and list of approved
components
G.1 Test report
G.2 List of approved components
Annex H (informative) - Example methodology for theoretical
analysis
H.1 Introduction
H.2 Points for analysis
H.2.1 General
H.2.2 List of characteristics
Bibliography
This European Standard specifies requirements, methods of test and performance criteria against which the compatibility of components and their performance can be assessed when used in combination to form an electrically controlled hold-open system. It also specifies requirements for the integrity of such hold-open systems when connected to fire detection and fire alarm systems or other systems, including the signal exchange and technical data for interfaces.This European Standard provides requirements for the application of electrically controlled hold-open systems used for fire/smoke doors in buildings, where such doors are required to be self-closing. It covers planning, design (see Annex A), installation (see Annex B), commissioning, use and maintenance (see Annex E) of hold-open systems, intended for the protection of life and/or the protection of property. This may also include hold-open systems, or components of the hold-open system, that are self-contained in a single enclosure.Electrically controlled hold-open systems manufactured, installed and serviced in accordance with this European Standard are recommended for use wherever there is a requirement for reliable hold-open and release of an individual self-closing fire/smoke door assembly in the case of fire.The use of hold-open systems for closures in conveyor systems conforming to EN 1366-7, which applies in conjunction with EN 1363-1, may require additional proof of suitability, which is not covered by this European Standard.This European Standard does not cover design, installation, commissioning, use and maintenance of building fire detection and fire alarm systems (covered by CEN/TS 54-14) but does cover the connection of hold-open systems conforming to this European Standard to building fire detection and fire alarm systems, under certain prescribed conditions.This European Standard does not cover the requirements of performance characteristics and operational environment conditions of part
Committee |
CEN/TC 33
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
DIN EN 14637:2008-01 | Identical |
UNE-EN 14637:2008 | Identical |
NF EN 14637 : 2008 | Identical |
UNI EN 14637 : 2008 | Identical |
NBN EN 14637 : 2008 | Identical |
NS EN 14637 : 1ED 2007 | Identical |
SN EN 14637 : 2007 | Identical |
I.S. EN 14637:2007 | Identical |
BS EN 14637:2007 | Identical |
NEN EN 14637 : 2007 | Identical |
PN EN 14637 : 2007 | Identical |
BS EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows. Product standard, performance characteristics. Fire resisting and/or smoke control characteristics |
I.S. EN 16034:2014 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS |
UNI EN 16034 : 2014 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS |
11/30249544 DC : 0 | BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE |
VDI 6010 Blatt 2:2011-05 | Technical safety installations - Automation and control of fire protective services |
S.R. CEN TR 15894:2009 | BUILDING HARDWARE - DOOR FITTINGS FOR USE BY CHILDREN, ELDERLY AND DISABLED PEOPLE IN DOMESTIC AND PUBLIC BUILDINGS - A GUIDE FOR SPECIFIERS |
UNE-EN 16034:2015 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
DIN EN 16034:2014-12 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resistance and/or smoke control characteristics; German version EN 16034:2014 |
EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
PD CEN/TR 15894:2009 | Building hardware. Door fittings for use by children, elderly and disabled people in domestic and public buildings. A guide for specifiers |
UNI CEN/TR 15894 : 2009 | BUILDING HARDWARE - DOOR FITTINGS FOR USE BY CHILDREN, ELDERLY AND DISABLED PEOPLE IN DOMESTIC AND PUBLIC BUILDINGS - A GUIDE FOR SPECIFIERS |
CEN/TR 15894:2009 | Building hardware - Door fittings for use by children, elderly and disabled people in domestic and public buildings - A guide for specifiers |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
NFS 61 937 : 1990 AMD 1 2006 | FIRE SAFETY - OPERATED SAFETY DEVICES |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
NFS 61 950 : 2004 | FIRE DETECTION EQUIPMENT - LINEAR HEAT AND MULTIPOINT SMOKE DETECTORS AND INTERMEDIATE ELEMENTS |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
EN 12605:2000 | Industrial, commercial and garage doors and gates - Mechanical aspects - Test methods |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 54-5:2017 | Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 61000-3-3:2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60950-1:2006/A2:2013 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED) |
EN 12978:2003+A1:2009 | Industrial, commercial and garage doors and gates - Safety devices for power operated doors and gates - Requirements and test methods |
CEN/TS 54-14:2004 | Fire detection and fire alarm systems - Part 14: Guidelines for planning, design, installation, commissioning, use and maintenance |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
EN 1366-7:2004 | Fire resistance tests for service installations - Part 7: Conveyor systems and their closures |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60669-1:2017 | Switches for household and similar fixed-electrical installations - Part 1: General requirements |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
ISO 9001:2015 | Quality management systems — Requirements |
EN 1363-1:2012 | Fire resistance tests - Part 1: General Requirements |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
NFS 61 961 : 2007 | FIRE DETECTION EQUIPMENT - ACTUATING DETECTOR SYSTEMS |
EN 54-13:2017 | Fire detection and fire alarm systems - Part 13: Compatibility and connectability assessment of system components |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
EN 1191:2012 | Windows and doors - Resistance to repeated opening and closing - Test method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.