Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation
06-05-2011
1 Scope
2 Normative references
3 Terms and definitions
4 General purpose cable
5 Heat resistant cables (90 degree C)
Annex A (normative) - Tests for cables to EN 50525-2-31
Annex B (normative) - General data
Bibliography
EN 50525-2-31 applies to non-sheathed single core cables insulated with thermoplastic (PVC) insulation. The cables are of rated voltages U0/U up to and including 450/750 V. The cables are intended for fixed wiring applications. NOTE 1 Cables rated 450/750 V may be used at 600/1 000 V when this cable is used in fixed installations with mechanical protection, within switchgear and control gear - see HD 516. The maximum conductor operating temperatures for the cables in this standard are 70 °C (V types) and 90 °C (V2 types). NOTE 2 HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-31 should be read in conjunction with EN 50525-1, which specifies general requirements.
Committee |
CLC/TC 20
|
DevelopmentNote |
Supersedes HD 21-3 and HD 21 PT7. To be read in conjunction with EN 50525-1. (05/2011) Supersedes PREN 50525-2-31. (08/2011)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NBN EN 50525-2-31 : 2011 | Identical |
I.S. EN 50525-2-31:2011 | Identical |
VDE 0285-525-2-31 : 2012 | Identical |
CEI EN 50525-2-31 : 2012 | Identical |
NEN EN 50525-2-31 : 2011 | Identical |
BS EN 50525-2-31:2011 | Identical |
PN EN 50525-2-31 : 2011 | Identical |
DIN EN 50525-2-31 : 2012 | Identical |
NF EN 50525-2-31 : 2012 | Identical |
UNE-EN 50525-2-31:2012 | Identical |
BS EN 62080:2009+A2:2015 | Identical |
I.S. EN 50628:2016 | ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
I.S. EN 60335-1:2012 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS |
13/30251809 DC : 0 | BS EN 50171 - CENTRAL SAFETY POWER SUPPLY SYSTEMS |
BS EN 60335-1 : 2012 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
PREN 50171 : DRAFT 2013 | CENTRAL SAFETY POWER SUPPLY SYSTEMS |
BS EN 50628:2016 | Erection of electrical installations in underground mines |
UNE-EN 60335-1:2012 | Household and similar electrical appliances - Safety - Part 1: General requirements |
EN 50628:2016 | Erection of electrical installations in underground mines |
EN 60719:1993 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
IEC 60228:2004 | Conductors of insulated cables |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60719:1992 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
EN 50525-1:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements |
EN 50363-3 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS |
HD 516 S2:1997/A2:2008 | GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES |
EN 50395 : 2005 AMD 1 2011 | ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
IEC 60811-1-4:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature |
EN 50396 : 2005 AMD 1 2011 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
EN 60811-1-4:1995/A2:2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.