EN 50600-2-2:2014
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Information technology - Data centre facilities and infrastructures - Part 2-2: Power distribution
06-01-2015
21-03-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Conformance
5 Power supply and distribution within
data centres
6 Availability
7 Physical security
8 Energy efficiency enablement and
power distribution
Annex A (informative) - Example implementations of
power distribution
Bibliography
This European Standard addresses power supplies to, and power distribution within, data centres based upon the criteria and classifications for “availability”, “physical security” and “energy efficiency enablement” within EN 50600 1. This European Standard specifies requirements and recommendations for the following: a)power supplies to data centres; b)power distribution systems within data centres; c)facilities for both normal and emergency lighting; d)equipotential bonding and earthing; e)lightning protection; f)devices for the measurement of the power consumption characteristics at points along the power distribution system and their integration within management tools. Safety and electromagnetic compatibility (EMC) requirements are outside the scope of this European Standard and are covered by other standards and regulations. However, information given in this European Standard may be of assistance in meeting these standards and regulations. Conformance of data centres to the present document is covered in Clause 4.
Committee |
CLC/TC 215
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
NBN EN 50600-2-2 : 2014 | Identical |
NEN EN 50600-2-2 : 2014 | Identical |
I.S. EN 50600-2-2:2014 | Identical |
OVE/ONORM EN 50600-2-2 : 2014 AC 2017 | Identical |
PN EN 50600-2-2 : 2014 | Identical |
SN EN 50600-2-2 : 2014 | Identical |
DIN EN 50600-2-2 : 2014 COR 1 2016 | Identical |
VDE 0801-600-2-2 : 2014 COR 1 2016 | Identical |
BS EN 50600-2-2:2014 | Identical |
CEI EN 50600-2-2 : 2015 | Identical |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
IEC 60050-131:2002 | International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory |
IEC 61000-2-4:2002 | Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances |
EN 50600-2-1:2014 | Information technology - Data centre facilities and infrastructures - Part 2-1: Building construction |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
EN 50174-1:2009/A2:2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
EN 61000-2-4:2002/AC:2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
EN 50174-3:2013/A1:2017 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
IEC 88528-11:2004 | Reciprocating internal combustion engine driven alternating current generating sets - Part 11: Rotary uninterruptible power systems - Performance requirements and test methods |
HD 60364-4-444:2010/AC:2012 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES |
EN 50600-1:2012 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 1: GENERAL CONCEPTS |
EN 50174-2 : 2009 AMD 2 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
IEC 60044-1:1996+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 1: Current transformers |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
EN 50600-2-4:2015 | Information technology - Data centre facilities and infrastructures - Part 2-4: Telecommunications cabling infrastructure |
PREN 50600-2-5 : DRAFT 2012 | BS EN 50600-2-5 - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS |
PREN 50600-2-3 : DRAFT 2012 | DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-3: ENVIRONMENTAL CONTROL |
EN 60044-1:1999/A2:2003 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
EN 50310:2016 | Telecommunications bonding networks for buildings and other structures |
EN 88528-11 : 2004 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN ALTERNATING CURRENT GENERATING SETS - PART 11: ROTARY UNINTERRUPTIBLE POWER SYSTEMS - PERFORMANCE REQUIREMENTS AND TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.