EN 60298:1996/A11:1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV

Amendment of

EN 60298:1996

Superseded date

01-02-2004

Published date

12-01-2013

Sorry this product is not available in your region.

Committees responsible
National foreword
Foreword
Section 1 - General
1 Scope
Section 2 - Service conditions
2 Normal and special service conditions
Section 3 - Terms and definitions
3 Definitions
Section 4 - Rated characteristics
4 Rating
4.1 Rated voltage
4.2 Rated insulation level
4.3 Rated frequency
4.4 Rated normal current and temperature rise
4.5 Rated short-time withstand current
4.6 Rated peak withstand current
4.7 Rated duration of short circuit
4.8 Rated supply voltage of closing and opening
       devices and auxiliary circuits
4.9 Rated supply frequency of operating devices and
       auxiliary circuits
4.10 Rated pressure of compressed gas supply
       for operation
4.101 Rated filling pressure
       (of gas-filled compartments)
Section 5 - Rules for design and construction
5 Design
5.1 Requirements for liquids in switchgear
       and controlgear
5.2 Requirements for gases in switchgear
       and controlgear
5.3 Earthing
5.4 Auxiliary equipment
5.5 Dependent power closing
5.6 Stored energy closing
5.7 Operating of releases
5.8 Low and high pressure interlocking devices
5.9 Nameplates
5.101 Degree of protection and internal fault
5.102 Enclosure
5.103 Partitions and shutters
5.104 Pressure relief of gas-filled compartments
5.105 Disconnectors and earthing switches
5.106 Interlocks
5.107 Provisions for dielectric tests on cables
Section 6 - Rules for type tests
6 Type tests
6.1 Dielectric tests
6.2 Radio interference voltage (RIV) tests
6.3 Temperature-rise tests
6.4 Measurement of the resistance of the
       main circuit
6.5 Short-time and peak withstand current tests
6.101 Verification of making and breaking
       capacities
6.102 Mechanical operation tests
6.103 Verification of the IP-coding
6.104 Pressure withstand test for gas-filled
       compartments
6.105 Gas tightness tests of gas-filled
       compartments
6.106 Measurement of leakage currents
6.107 Weatherproofing test
6.108 Arcing due to internal fault
6.109 Mechanical impact tests
Section 7 - Rules for routine tests
7 Routine tests
7.1 Power-frequency voltage tests on the
       main circuit
7.2 Dielectric tests on auxiliary and control
       circuits
7.3 Measurement of the resistance of the
       main circuit
7.101 Partial discharge measurement
7.102 Mechanical operation tests
7.103 Pressure tests of gas-filled compartments
7.104 Gas tightness tests of gas-filled compartments
7.105 Tests of auxiliary electrical, pneumatic and
       hydraulic devices
7.106 Verification of correct wiring
7.107 Tests after erection on site
7.108 Measurement of gas condition after filling
       on site
Section 8 - General information
8 Guide to the selection of switching devices
       for service
9 Information to be given with enquiries,
       tenders for service
9.101 Information with enquiries and orders
9.102 Information with tenders
10 Rules for transport, storage, erection and
       maintenance
10.1 Conditions during transport, storage and
       erection
10.2 Erection (mounting)
10.3 Maintenance
Figure
1 Standard test finger
Annexes
AA (normative) Internal fault
BB (normative) Method for calculating the
       cross-sectional area of bare conductors
       with regard to thermal stresses due to
       currents of short duration
CC Deleted
DD (normative) Guide to voltage tests after
       erection on site
EE (normative) Rated insulation level for
       Series II
FF (normative) Partial discharge measurement
GG Deleted
ZA (normative) Normative references to
       international publications with their
       corresponding European publications
ZB (normative) Special national conditions
ZC (informative) A-deviations

Gives requirements for factory-assembled metal-enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 52 kV for indoor and outdoor installation, and for service frequencies up to and including 60 Hz.

Committee
TC 17AC
DevelopmentNote
Supersedes HD 187 (07/2001)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

BS EN 50123-7-3:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating voltage transducers and other voltage measuring devices
I.S. EN 50123-4:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
I.S. EN 50123-1:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - GENERAL
I.S. EN 61958:2001 HIGH-VOLTAGE PREFABRICATED SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - VOLTAGE PRESENCE INDICATING SYSTEMS
EN 60204-11:2000/corrigendum:2010 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
HD 637 S1:1999/corrigendum:2005 POWER INSTALLATIONS EXCEEDING 1 KV A.C.
BS EN 45510-2-7:2002 Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear
CEI UNI EN 45510-2-7 : 2006 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
EN 50123-7-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-2: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating current transducers and other current measuring devices
BS EN 50123-1:2003 Railway applications. Fixed installations. D.C. switchgear General
I.S. HD 637:1999 POWER INSTALLATIONS EXCEEDING 1 KV A.C.
I.S. EN 50123-7-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES
I.S. EN 50123-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
BS EN 50123-7-1:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Measurement, control and protection devices for specific use in d.c. traction systems. Application guide
CEI EN 50123-1 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL
I.S. EN 45510-2-7:2002 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
API 14F : 2008 : R2013 DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS
I.S. EN 60204-11:2000 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
BS EN 50123-2:2003 Railway applications. Fixed installations. D.C. switchgear D.C. circuit breakers
BS EN 60204-11 : 2001 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
UNI CEI EN 45510-2-7 : 2011 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
I.S. EN 50123-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - D.C. CIRCUIT BREAKERS
API RP 14F:2008 DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS
I.S. EN 50123-7-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING VOLTAGE TRANSDUCERS AND OTHER VOLTAGE MEASURING DEVICES
EN 45510-2-7:2002 Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear
EN 50123-7-3:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-3: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating voltage transducers and other voltage measuring devices
DIN EN 45510-2-7:2003-12 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
BS EN 60470:2001 High-voltage alternating current contactors and contactor-based motor starters
CEI EN 50187 : 1998 GAS-FILLED COMPARTMENTS FOR A.C. SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
I.S. EN 62271-102:2005 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001 (EQV))
BS EN 50123-7-2:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating current transducers and other current measuring devices
API 14F REDLINE : 2008 DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS
EN 61958:2001 High-voltage prefabricated switchgear and controlgear assemblies - Voltage presence indicating systems
EN 50123-7-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-1: Measurement, control and protection devices for specific use in d.c. traction systems - Application guide
EN 50187 : 96 AC 96 GAS-FILLED COMPARTMENTS FOR A.C. SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
EN 50123-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 1: General
EN 50123-4:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
EN 50123-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 2: D.C. circuit breakers
EN 50123-3:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES

IEC 60243-1:2013 Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies
IEC 60480:2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 60056:1987 High-voltage alternating-current circuit-breakers
IEC 60517:1990 Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
IEC 60129:1984 Alternating current disconnectors and earthing switches
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.