EN 60687:1992/corrigendum:1993
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ALTERNATING CURRENT STATIC WATT HOUR METERS FOR ACTIVE ENERGY (CLASSES 0.2S AND 0.5S)
01-03-2003
12-01-2013
Cooperating organizations
National foreword
Foreword
1. Scope
2. Normative references
3. Definitions
3.1 General definitions
3.2 Definitions related to the functional elements
3.3 Definitions of mechanical elements
3.4 Definitions of insulations
3.5 Definitions of meter quantities
3.6 Definitions of influence quantities
3.7 Definition of tests
4. Requirements
4.1 Standard electrical values
4.2 Mechanical requirements
4.3 Climatic conditions
4.4 Electrical requirements
4.5 Electromagnetic compatibility (EMC)
4.6 Accuracy requirements
5. Tests and test conditions
5.1 General testing procedures
5.2 Tests of mechanical requirements
5.3 Tests of climatic influences
5.4 Tests of electrical requirements
5.5 Tests for electromagnetic compatibility (EMC)
5.6 Tests of accuracy requirements
Annexes
A. Relationship between ambient air temperature and
relative humidity
B. Voltage wave-form for the tests of the effect of
voltage dips and short interruptions
C. Electromagnet for testing the influence of
externally-produced magnetic fields
D. Test schedule
ZA. Special national conditions
ZB. Other international publications quoted in this
standard with the references of the relevant
European publications
Tables
1. Standard reference voltages
2. Clearances and creepage distances for the terminal
block
3. Voltage marking
4. Temperature range
5. Relative humidity
6. Power consumption including the power supply
7. Voltage range
8. Variations due to self-heating
9. Percentage error limits (single-phase meters and
polyphase meters with balanced loads)
10. Percentage error limits (polyphase meters carrying
a single-phase load, but with balanced polyphase
voltages applied to voltage circuits)
11. Influence quantities
12. Temperature coefficient
13. AC voltage tests
14. Voltage and current balance
15. Reference conditions
16. Interpretation of test results
National annex NA (informative) Committees responsible
National annex NB (informative) Cross-references
Deals with the measurement (by static watt hour meters of accuracy classes 0,2 S and 0,5 S) of alternating current electrical active energy of a frequency between 45Hz to 65 Hz and to their type tests only. Applies transformer operated static meters for indoor application consisting of one or more measuring elements and registers enclosed together in the same case. Also applies to test outputs, operation indicators and meters that measure energy in both directions. Does not apply to: portable meters and meters for outdoor use; watt hour meters where the voltage across the connection terminals exceeds 600 V (line to line voltage for meters for polyphase systems); data interface to the register of the meter; reference meters.
Committee |
TC 13
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
I.S. EN 60687:1993 | Identical |
UNE-EN 60687:1994 | Identical |
BS EN 60687:1993 | Identical |
NBN EN 60687 : 1993 | Identical |
CEI EN 60687 : 2ED 1997 | Identical |
SN EN 60687 : 1992 | Identical |
NEN 10687 : 1993 | Identical |
VDE 0418-8 : 1994 | Identical |
NF EN 60687 : 1993 | Identical |
IEC 60687:1992 | Identical |
DIN EN 60687 : 1994 | Identical |
BS EN 61036:1997 | Alternating current static watt-hour meters for active energy (classes 1 and 2) |
I.S. EN 62053-61:1999 | ELECTRICITY METERING EQUIPMENT (A.C.) - PARTICULAR REQUIREMENTS - PART 61: POWER CONSUMPTION AND VOLTAGE REQUIREMENTS |
EN 62053-31:1998 | Electricity metering equipment (a.c.) - Particular requirements - Part 31: Pulse output devices for electromechanical and electronic meters (two wires only) |
EN 62053-61:1998 | Electricity metering equipment (a.c.) - Particular requirements - Part 61: Power consumption and voltage requirements |
95/214875 DC : 0 | PREN 50222 - STANDARD FOR THE EVALUATION OF MEASUREMENT RESULTS TAKING MEASUREMENT UNCERTAINTY INTO ACCOUNT |
BS EN 62053-31:1999 | Electricity metering equipment (a.c.). Particular requirements Pulse output devices for electromechanical and electronic meters (two wires only) |
CEI EN 62053-31 : 1999 | ELECTRICITY METERING EQUIPMENT (A.C.) - PARTICULAR REQUIREMENTS - PART 31: PULSE OUTPUT DEVICES FOR ELECTROMECHANICAL AND ELECTRONIC METERS (TWO WIRES ONLY) |
I.S. EN 61036:1997 | ALTERNATING CURRENT STATIC WATT-HOUR METERS FOR ACTIVE ENERGY (CLASSES 1 AND 2) |
CEI EN 62053-61 : 1999 | ELECTRICITY METERING EQUIPMENT (A.C.) - PARTICULAR REQUIREMENTS - PART 61: POWER CONSUMPTION AND VOLTAGE REQUIREMENTS |
BS EN 62053-61:1999 | Electricity metering equipment (a.c.). Particular requirements Power consumption and voltage requirements |
EN 61036:1996/A1:2000 | ALTERNATING CURRENT STATIC WATT-HOUR METERS FOR ACTIVE ENERGY (CLASSES 1 AND 2) |
IEC 60038:2009 | IEC standard voltages |
IEC 60695-2-1:1991 | Fire hazard testing - Part 2: Test methods - Section 1: Glow-wire test and guidance |
IEC 60521:1988 | Class 0.5, 1 and 2 alternating-current watthour meters |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC TR 60736:1982 | Testing equipment for electrical energy meters |
ISO 75:1987 | Plastics and ebonite Determination of temperature of deflection under load |
IEC 60801-4:1988 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 4: Electrical fast transient/burst requirements |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
IEC 60817:1984 | Spring-operated impact-test apparatus and its calibration |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60801-1:1984 | Electromagnetic compatibility for industrial-process measurement and control equipment. Part 1: General introduction |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60801-3:1984 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 3: Radiated electromagnetic field requirements |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
IEC 60417C:1977 | Third supplement. |
IEC 60359:2001 | Electrical and electronic measurement equipment - Expression of performance |
IEC 60186:1987 | Voltage transformers |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60387:1992 | Symbols for alternating-current electricity meters |
IEC 61036:1996+AMD1:2000 CSV | Alternating current static watt-hour meters for active energy (classes 1 and 2) |
IEC 60801-2:1991 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 2: Electrostatic discharge requirements |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.