• Shopping Cart
    There are no items in your cart

EN 61952:2008

Current

Current

The latest, up-to-date edition.

Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria

Published date

15-10-2008

Sorry this product is not available in your region.

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviations
5 Identification
6 Environmental conditions
7 Transport, storage and installation
8 Tolerances
9 Classification of tests
   9.1 Design tests
   9.2 Type tests
   9.3 Sample tests
   9.4 Routine tests
10 Design tests
   10.1 General
   10.2 Test specimens for IEC 62217
        10.2.1 Tests on interfaces and connections of
               end fittings
        10.2.2 Tracking and erosion test
        10.2.3 Tests on core material
   10.3 Product specific pre-stressing for IEC 62217
        tests on interfaces and connections of end fittings
        10.3.1 Thermal-mechanical pre-stressing
   10.4 Assembled core load tests
        10.4.1 Test for the verification of the maximum
               design cantilever load (MDCL)
        10.4.2 Tensile load test
11 Type tests
   11.1 Electrical tests
        11.1.1 Vertical mounting arrangement
        11.1.2 Horizontal mounting arrangement
   11.2 Mechanical tests
        11.2.1 Cantilever failing load test
12 Sample tests
   12.1 General rules
   12.2 Verification of dimensions (E1 + E2)
   12.3 Galvanizing test (E1 + E2)
   12.4 Verification of the SCL (E1)
        12.4.1 Test procedure
        12.4.2 Acceptance criteria
   12.5 Re-testing procedure
13 Routine tests
   13.1 Tensile load test
   13.2 Visual examination
Annex A (informative) - Notes on the mechanical loads
        and tests
Annex B (informative) - Determination of the equivalent
        bending moment caused by combined loads
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications
Bibliography

IEC 61952:2008 applies to composite line post insulators consisting of a load-bearing, cylindrical, insulating solid core made up of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of elastomer material (e.g. silicone or ethylene-propylene) and end fittings permanently attached to the insulating core.

Committee
SR 36
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

Standards Relationship
NF EN 61952 : 2008 Identical
IEC 61952:2008 Identical
NBN EN 61952 : 2009 Identical
NEN EN IEC 61952 : 2008 Identical
I.S. EN 61952:2008 Identical
PN EN 61952 : 2010 Identical
SN EN 61952 : 2003 Identical
VDE 0441-200 : 2009 Identical
DIN EN 61952 : 2009 Identical
BS EN 61952:2008 Identical
UNE-EN 61952:2010 Identical
CEI EN 61952 : 2009 Identical
BS EN IEC 60794-2-30:2019 Identical

UNE-EN 50341-1:2017 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
PREN 50119 : DRAFT 2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
BS EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications
EN 50151 : 2003 COR 2010 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIAL REQUIREMENTS FOR COMPOSITE INSULATORS
I.S. EN 50151:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIAL REQUIREMENTS FOR COMPOSITE INSULATORS
BS EN 50119 : 2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
17/30341013 DC : DRAFT AUG 2017 BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
BS EN 62621 : 2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS (IEC 62621:2011)
EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
I.S. EN 50119:2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
NF EN 50119 : 2010 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
I.S. EN 50341-1:2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
CEI EN 50341-1 : 2013 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
12/30260570 DC : 0 BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
BS EN 50151:2003 Railway applications. Fixed installations. Electric traction. Special requirements for composite insulators
I.S. EN 50119:2020 Railway applications - Fixed installations - Electric traction overhead contact lines
UNE-EN 62621:2016 Railway applications - Fixed installations - Electric traction - Specific requirements for composite insulators used for overhead contact line systems
EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
PREN 50341-1 : DRAFT 2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
I.S. EN 62621:2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS
EN 62621:2016/A1:2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS

IEC 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
IEC 60050-471:2007 International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
IEC 60383-1:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria
EN 61462:2007 Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations
EN 60383-1:1996/A11:1999 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC OR GLASS INSULATOR UNITS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
ISO 3452:1984 Non-destructive testing — Penetrant inspection — General principles
EN 60507:2014 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 61462:2007 Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations
IEC GUIDE 111:2004 Electrical high-voltage equipment in high-voltage substations - Common recommendations for product standards
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
IEC 60383-2:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria
EN 60383-2:1995 Insulators for overhead lines with a nominal voltage above 1 kV - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.