EN ISO 15012-4:2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Health and safety in welding and allied processes - Equipment for capture and separation of welding fume - Part 4: General requirements (ISO 15012-4:2016)
30-03-2022
20-07-2016
European foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Significant hazards
5 Requirements and verifications
6 Instructions for use
7 Marking
Annex A (informative) - Malfunctions and determination
of minimum airflow
Bibliography
Annex ZA (informative) - Relationship between this
European Standard and the essential requirements of
EU Directive 2006/42/EC aimed to be covered
ISO 15012-4:2016 defines the general requirements for ventilation equipment used to control exposure to fumes generated by welding and allied processes. It applies to the design and manufacture of all parts of the equipment including hoods, ducting, filter units, air movers, systems that inform of unsafe operation and workplace practices to ensure safe working with regard to exposure.Significant hazards are listed in Clause 4. It does not cover electrical, mechanical and pneumatic hazards.ISO 15012-4:2016 is applicable to the following:- local exhaust ventilation systems (LEV);- mobile and stationary equipment.It is not applicable to the following:- general ventilation, air make up or air movement systems;- air conditioning systems;- separation of gases generated by or used by welding and allied processes;- LEV used for welding and allied processes that generate reactive potentially explosive particles and atmospheres;- grinding dust.ISO 15012-4:2016 applies to systems designed and manufactured after its publication.
Committee |
CEN/TC 121
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN ISO 15012-4 : 2016 | Identical |
SN EN ISO 15012-4 : 2016 | Identical |
DIN EN ISO 15012-4:2015-07 (Draft) | Identical |
UNI EN ISO 15012-4 : 2016 | Identical |
UNE-EN ISO 15012-4:2016 | Identical |
NEN EN ISO 15012-4 : 2016 | Identical |
BS EN ISO 15012-4:2016 | Identical |
NS EN ISO 15012-4 : 2016 | Identical |
I.S. EN ISO 15012-4:2016 | Identical |
PN EN ISO 15012-4 : 2016 | Identical |
ISO 15012-4:2016 | Identical |
SS-EN ISO 15012-4:2016 | Identical |
DIN EN ISO 15012-4:2016-11 | Identical |
ISO 14341:2010 | Welding consumables Wire electrodes and weld deposits for gas shielded metal arc welding of non alloy and fine grain steels Classification |
EN 1093-1:2008 | Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 1: Selection of test methods |
ISO 17916:2016 | Safety of thermal cutting machines |
EN 1093-3:2006+A1:2008 | Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 3: Test bench method for the measurement of the emission rate of a given pollutant |
IEC 60204-1:2016 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
ISO 15012-1:2013 | Health and safety in welding and allied processes Equipment for capture and separation of welding fume Part 1: Requirements for testing and marking of separation efficiency |
ISO 12100:2010 | Safety of machinery — General principles for design — Risk assessment and risk reduction |
ISO 7731:2003 | Ergonomics Danger signals for public and work areas Auditory danger signals |
IEC 60335-2-69:2016 | Household and similar electrical appliances - Safety - Part 2-69: Particular requirements for wet and dry vacuum cleaners, including power brush, for commercial use |
ISO 2602:1980 | Statistical interpretation of test results Estimation of the mean Confidence interval |
ISO 5801:2017 | Fans — Performance testing using standardized airways |
ISO 15012-2:2008 | Health and safety in welding and allied processes Requirements, testing and marking of equipment for air filtration Part 2: Determination of the minimum air volume flow rate of captor hoods and nozzles |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
EN 1093-7:1998+A1:2008 | Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 7: Separation efficiency by mass, ducted outlet |
EN 842:1996+A1:2008 | Safety of machinery - Visual danger signals - General requirements, design and testing |
ISO 3966:2008 | Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes |
EN 1093-6:1998+A1:2008 | Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 6: Separation efficiency by mass, unducted outlet |
EN 1070 : 1998 | SAFETY OF MACHINERY - TERMINOLOGY |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.