• Shopping Cart
    There are no items in your cart

HB 331-2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Overhead line design

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

28-07-2024

Superseded by

SA/SNZ HB 331:2020

Language(s)

English

Published date

04-04-2012

€107.51
Excluding VAT

This Handbook provides support for AS/NZS 7000:2010, which is the Standard that provides requirements, methods and guidance for the design and construction of overhead electrical power lines. It applies to alternating current lines operating at a nominal frequency of 50 Hz.

Committee
EL-052
DocumentType
Handbook
ISBN
978 1 74342 061
Pages
269
PublisherName
Standards Australia
Status
Superseded
SupersededBy

This Handbook is a companion to and is intended to be read in conjunction with the Overhead Line Design Standard, AS/NZS 7000, Overhead line design - Detailed procedures (referred to as AS/NZS 7000 in this Handbook), which is a comprehensive treatment on the design of overhead power lines and which supersedes the ENA C(b)1 Guidelines for the Design and Maintenance of Overhead Distribution and Transmission Lines.

First published as HB 331 2012.

HB 158-2010 Delivering assurance based on ISO 31000:2009 Risk management - Principles and guidelines
AS 1604.1-2010 Specification for preservative treatment Sawn and round timber
AS 3818.11-2009 Timber - Heavy structural products - Visually graded Utility poles
AS/NZS 4065:2010 Concrete utility services poles
AS 3766-1990 Mechanical fittings for low voltage aerial bundled cables
AS 3822-2002 Test methods for bare overhead conductors
AS 3891.1-2008 Air navigation - Cables and their supporting structures - Marking and safety requirements Permanent marking of overhead cables and their supporting structures for other than planned low-level flying
AS/NZS 1170.2:2002 Structural design actions Wind actions
HB 103-1997 (CJC 7) Coordination of power and telecommunications - Crossings code - The arrangement of overhead power and telecommunications lines, pole stay wires, and suspension wires
AS/NZS 1891.1:2007 Industrial fall-arrest systems and devices Harnesses and ancillary equipment
HB 219:2006 Earth potential rise - Protection of telecommunications network users, personnel and plant - Worked examples for the application guide (Reconfirmed 2020)
AS/NZS 4680:2006 Hot-dip galvanized (zinc) coatings on fabricated ferrous articles (Reconfirmed 2017)
AS/NZS 3560.1:2000 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1(1.2) kV Aluminium conductors (Reconfirmed 2021)
AS 60305-2007 Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic or glass insulator units for a.c. systems - Characteristics of insulator units of the cap and pin type
AS 1222.1-1992 Steel conductors and stays - Bare overhead Galvanized (SC/GZ) (Reconfirmed 2016)
AS/NZS 2878:2000 Timber - Classification into strength groups
AS 1531-1991 Conductors - Bare overhead - Aluminium and aluminium alloy (Reconfirmed 2016)
AS/NZS 3675:2002 Conductors - Covered overhead - For working voltages 6.35/11 (12) kV up to and including 19/33 (36) kV (Reconfirmed 2017)
AS 1720.2-2006 Timber structures Timber properties
AS 3818.4-2010 Timber - Heavy structural products - Visually graded Cross-arms for overhead lines
HB 102-1997 (CJC 6) Coordination of power and telecommunications - Low Frequency Induction (LFI) - Application Guide to the LFI Code
AS 1824.2-1985 Insulation coordination (phase-to-earth and phase-to-phase, above 1 kV) - Application guide
AS 1746-1991 Conductors - Bare overhead - Hard-drawn copper
HB 101-1997 (CJC 5) Coordination of power and telecommunications - Low Frequency Induction (LFI) - Code of practice for the mitigation of hazardous voltages induced into telecommunications lines
AS/NZS 3599.1:2003 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11 (12) kV and 12.7/22 (24) kV Metallic screened (Reconfirmed 2021)
AS 3818.1-2009 Timber - Heavy structural products - Visually graded General requirements
AS/NZS 7000:2010 Overhead line design - Detailed procedures
AS/NZS 3835.2:2006 Earth potential rise - Protection of telecommunications network users, personnel and plant Application guide
AS/NZS 3845:1999 Road safety barrier systems
AS 4398.1-1996 Insulators - Ceramic or glass - Station post for indoor and outdoor use - Voltages greater than 1000 V a.c. Characteristics (Reconfirmed 2016)
AS/NZS 1158.1.2:2010 Lighting for roads and public spaces Vehicular traffic (Category V) lighting - Guide to design, installation, operation and maintenance
AS/NZS 4435.2:1999 Insulators - Composite for overhead power lines - Voltages greater than 1000 V a.c. Standard strength classes and end fittings for string insulator units (Reconfirmed 2016)
AS/NZS 1170.2:2011 Structural design actions Wind actions (Reconfirmed 2016)
AS/NZS ISO 31000:2009 Risk management - Principles and guidelines
AS 1154.3-2009 Insulator and conductor fittings for overhead power lines Performance and general requirements for helical fittings (Reconfirmed 2019)
AS 1720.1-2010 Timber structures Design methods
HB 100-2000 (CJC 4) COORDINATION OF POWER AND TELECOMMUNICATIONS - Manual for the establishment of safe work practices and the minimization of operational interference between power systems and paired cable telecommunications systems
AS/NZS 2947.4:1999 Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. Test methods - Insulator strings and insulator sets
AS/NZS 4676:2000 Structural design requirements for utility services poles
AS 4436-1996 Guide for the selection of insulators in respect of polluted conditions
AS 4435.1-1996 Insulators - Composite for overhead lines - Voltages greater than 1000 V a.c. Definitions, test methods and acceptance criteria for string insulator units
AS 4799-2000 Installation of underground utility services and pipelines within railway boundaries
HB 108-1998 Timber Design Handbook - In accordance with the Australian Limit State Timber Design Code, AS 1720.1-1997
AS/NZS 1891.2:2001 Industrial fall-arrest systems and devices Horizontal lifeline and rail systems
SAA HB 88-1997 (CJC 2) Unbalanced high voltage power lines - Code of practice for the mitigation of noise induced into paired cable telecommunications lines from unbalanced high voltage power lines
AS 1154.1-2009 Insulator and conductor fittings for overhead power lines Performance, material, general requirements and dimensions (Reconfirmed 2019)
AS 5604-2005 Timber - Natural durability ratings (Reconfirmed 2016)
AS/NZS 3599.2:1999 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Non-metallic screened
AS 4398.2-2005 Insulators - Ceramic or glass - Station post for indoor or outdoor use - Voltages greater than 1000 V a.c. Tests (IEC 60168, Ed. 4.2 (2001) MOD)
HB 87-1997 (CJC 1) Joint use of poles, The placement on poles of power lines and paired cable telecommunications lines
AS/NZS 1559:1997 Hot-dip galvanized steel bolts and associated nuts and washers for tower construction
AS 3818.10-2010 Timber - Heavy structural products - Visually graded Building poles
AS 1289.6.3.1-2004 Methods of testing soils for engineering purposes Soil strength and consolidation tests - Determination of the penetration resistance of a soil - Standard penetration test (SPT) (Reconfirmed 2016)
AS/NZS 2344:1997 Limits of electromagnetic interference from overhead a.c. powerlines and high voltage equipment installations in the frequency range 0.15 to 1000 MHz
AS 3891.2-2008 Air navigation - Cables and their supporting structures - Marking and safety requirements Marking of overhead cables for planned low-level flying operations
AS 2067-2008 Substations and high voltage installations exceeding 1 kV a.c.
AS/NZS 2947.1:1999 Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. Test methods - Insulator units
AS 2209-1994 Timber - Poles for overhead lines
AS 1222.2-1992 Steel conductors and stays - Bare overhead Aluminium clad (SC/AC) (Reconfirmed 2016)
AS 6947-2009 Crossing of waterways by electricity infrastructure (Reconfirmed 2019)
AS/NZS 1891.3:1997 Industrial fall-arrest systems and devices - Fall-arrest devices
AS 4435.4-2005 Insulators - Composite for overhead power lines - Voltages greater than 1000 V a.c. Definitions, test methods, acceptance criteria for post insulator units (Reconfirmed 2016)
AS/NZS 3835.1:2006 Earth potential rise - Protection of telecommunications network users, personnel and plant Code of practice
AS/NZS 1891.4:2009 Industrial fall-arrest systems and devices Selection, use and maintenance

AS/NZS 7000:2016 Overhead line design
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.