• Shopping Cart
    There are no items in your cart

HD 604 S1:1994/A3:2005

Current

Current

The latest, up-to-date edition.

0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS

Amendment of

HD 604 S1:1994

Published date

28-10-2005

Sorry this product is not available in your region.

1 General
  1.1 Scope
  1.2 Object
2 Definitions
  2.1 Definitions relating to insulating and sheathing
      compounds
  2.2 Definitions relating to the tests
  2.3 Rated voltage
3 Marking
  3.1 Indication of origin
  3.2 Additional marking
  3.3 Durability
  3.4 Legibility
  3.5 Common marking
  3.6 Use of the name CENELEC
4 Core identification
5 General requirements for the construction of cables
  5.1 Conductors
  5.2 Insulation
  5.3 Fillers and tapes
  5.4 Inner covering (bedding)
  5.5 Inner sheath
  5.6 Metallic coverings
  5.7 Oversheath
  5.8 Non-metallic components of halogen free cables
6 Tests on complete cables
7 (spare)
8 (spare)
9 Guide to use and selection of cables

Applicable to rigid and flexible conductor cables for fixed installations having a rated voltage Uo/U of 0,6/1,0 kV or 1,9/3,3 kV.

Committee
TC 20
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

BS 7870-3.50:2005 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire. (Implementation of HD 603)
BS 7870-6.3:1999 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations - Cables with thermosetting insulation and non-halogenated sheath
I.S. EN 45510-2-8:2004 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES
BS 7870-3.12:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV - XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire
BS 7870-8.5:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath - Section 8.5 Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath
BS 7870-6.2:1999 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations - XLPE or HEPR insulated and PVC sheathed cables
BS EN 50363-9-1:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous insulating compounds. Cross-linked polyvinyl chloride (XLPVC)
BS 7870-3.21:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated split concentric cables with copper or aluminium conductors
CEI UNI EN 45510-2-8 : 2006 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES
I.S. HD 605:2008 ELECTRIC CABLES - ADDITIONAL TEST METHODS
I.S. HD 622:1999 POWER CABLES HAVING RATED VOLTAGES FROM 3,6/6(7,2) KV UP TO AND INCLUDING 20,8/36(42) KV WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS
EN 50363-10-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 10-1: Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC)
EN 45510-2-8 : 2004 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES
EN 50363-9-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 9-1: Miscellaneous insulating compounds - Cross-linked polyvinyl chloride (XLPVC)
I.S. EN 45510-2-9:2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
BS 7870-8.4:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and PVC sheathed multipair cable with copper conductors, having reduced fire propagation performance - Section 8.4 Single wire or double steel tape armoured and PVC sheathed multipair cable with copper conductors, having reduced fire propagation performance
BS EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables General introduction
BS 7870-3.40:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated, copper wire waveform concentric cables with solid aluminium conductors
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
BS EN 45510-2-8:2004 Guide for procurement of power station equipment Electrical equipment - Power cables
98/232755 DC : DRAFT DEC 1998 IEC 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
CEI 20-59 : 1999 MULTICORE AND MULTIPAIR CABLE FOR INSTALLATION ABOVE AND BELOW GROUND
I.S. EN 1366-3:2009 FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS
BS 7870-3.11:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors
BS 7870-5:1999 LV and MV polymeric insulated cables for use by distribution and generation utilities Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution
05/30126924 DC : DRAFT MAY 2005 BS 7870-3.50 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.50: XLPE INSULATED, COPPER WIRE WAVEFORM OR HELICAL CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE
BS 7870-3.10:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV PVC insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors
BS 7870-7.1:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single core and 3-core cables with halogenated materials and with aluminium or steel wire armouring
06/30154175 DC : 0 EN 1366-3 - FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS
BS 7870-8.6:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors - Section 8.6 Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors
EN 45510-2-9:2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
EN 45510-2-8:2004 Guide for procurement of power station equipment - Part 2-8: Electrical equipment - Power cables
BS 7870-8.1:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and PVC sheathed multicore cable with copper conductors - Section 8.1 Single wire armoured and PVC sheathed multicore cable with copper conductors
BS 7870-7.2:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single-core and 3-core cables with halogen-free materials and with aluminium or steel wire armouring
BS 7870-3.20:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV PVC insulated split concentric cables with copper or aluminium conductors
BS EN 50363-10-1:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Cross-linked polyvinyl chloride (XLPVC)
I.S. EN 50363-9-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 9-1: MISCELLANEOUS INSULATING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC)
I.S. EN 50363-0:2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW-VOLTAGE ENERGY CABLES - PART 0: GENERAL INTRODUCTION
BS EN 1366-3:2009 Fire resistance tests for service installations Penetration seals
UNE-EN 1366-3:2011 Fire resistance tests for service installations - Part 3: Penetration seals
EN 45510-2-9 : 2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
UNI EN 1366-3 : 2009 FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS
CEI 20-59 V1 : 2006 MULTICORE AND MULTIPAIR CABLE FOR INSTALLATION ABOVE AND BELOW GROUND
BS 7870-8.2:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and PVC sheathed multipair cable with copper conductors - Section 8.2 Single wire armoured and PVC sheathed multipair cable with copper conductors
BS 7870-8.3:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance - Section 8.3 Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance
UNI CEI EN 45510-2-8 : 2011 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES
UNE-EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables -- Part 0: General introduction
BS EN 45510-2-9:2008 Guide for procurement of power station equipment Electrical equipment. Cabling systems
EN 1366-3:2009 Fire resistance tests for service installations - Part 3: Penetration seals
EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction

EN 50267-2-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
IEC 60502-1:2004+AMD1:2009 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
EN 60332-1-2:2004/A11:2016 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015)
EN 50334:2001 Marking by inscription for the identification of cores of electric cables
EN 50267-2-2:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.