I.S. EN 61241-0:2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 0: GENERAL REQUIREMENTS
Hardcopy , PDF
08-09-2009
English
01-01-2006
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Construction
4.1 General
4.2 Principles for design and testing of apparatus
for use in Zone 20
4.3 Opening enclosures
4.4 Environmental conditions
5 Temperatures
5.1 Maximum surface temperature
5.2 Maximum surface temperature with respect to dust
layers above 50 mm
5.3 Ambient temperature
6 Enclosure materials
6.1 Non-metallic enclosures and non-metallic parts
of enclosures
6.2 Enclosures containing light metals
7 Fasteners
7.1 Access to live parts
7.2 Compatible material
8 Interlocking devices
9 Bushings
9.1 Prevention of turning
9.2 Torque tests
10 Materials used for cementing
10.1 Documentation
10.2 Thermal stability
10.3 Verification
11 Ex components
11.1 General
11.2 Mounting
11.3 Internal mounting
11.4 External mounting
12 Connection facilities and terminal compartments
12.1 Attached cables
12.2 Terminal access
12.3 Creepage and clearance
13 Connection facilities for earthing or bonding conductors
13.1 Internal connection
13.2 External connection
13.3 Facility not required
13.4 Effective connection
13.5 Effective contact
13.6 Environmental
13.7 Use of light metal
14 Cable and conduit entries
14.1 Intended use
14.2 Construction
14.3 Integral part of the apparatus
14.4 Prevention of twisting
14.5 Method of attaching
14.6 Blanking elements
14.7 Branching point temperatures
15 Radiating equipment
15.1 Lasers and other continuous wave source
15.2 Ultrasonic sources
16 Supplementary requirements for specific electrical
apparatus - Rotating electrical machines
16.1 Ventilation openings for external fans
16.2 Construction and mounting of the ventilating systems
16.3 Clearances for the ventilating system for use
in Zone 20 or 21
16.4 Materials for external fans and fanhoods
17 Switchgear
17.1 Flammable dielectric
17.2 Interlocking
17.3 Indication of open position
17.4 Openings
18 Fuses
19 Plugs and sockets
19.1 Plugs and sockets construction
19.2 Bolted plugs and sockets
19.3 For Zone 21 and Zone 22
19.4 Plugs remaining energized
20 Luminaries
20.1 Light transmitting covers
20.2 Guards
20.3 Mounting
20.4 Covers
20.5 Parts remaining energized
20.6 Types of lamps
21 Caplights, caplamps and handlamps
21.1 Leakage
21.2 Separate enclosures
22 Apparatus incorporating cells and batteries
22.1 General
22.2 Connection of cells
22.3 Characteristics
22.4 Compatibility
22.5 Limits
22.6 Mixture of cells
22.7 Interchangeability
22.8 Re-charging
22.9 Different cells
22.10 Leakage
22.11 Method of connection
22.12 Orientation
22.13 Identification of replacement
23 Verification and tests
23.1 General
23.2 Verification of documents
23.3 Compliance of prototype or sample with documents
23.4 Type tests
24 Routine verifications and tests
25 Manufacturer's responsibility
26 Verifications and tests on modified or repaired
electrical apparatus
27 Clamping tests of cable entries for non-armoured
and braided cables
27.1 Cable entries with clamping by the sealing ring
27.2 Cable entries with clamping by filling compound
27.3 Cable entries with clamping by means of a clamping
device
27.4 Tensile test
27.5 Mechanical strength
28 Clamping tests of cable entries for armoured cables
28.1 Clamping tests where the armourings are clamped by
a device within the gland
28.2 Clamping tests where the armourings are not clamped
by a device within the gland
29 Marking
29.1 General
29.2 Marking of all electrical apparatus
29.3 Multiple protection techniques
29.4 Order of marking
29.5 Reduced marking
30 Examples of marking
30.1 Apparatus type of protection "mD" for use in Zone 20
30.2 Apparatus type of protection "iaD" for use in Zone 20
30.3 Apparatus type of protection "pD" for use in Zone 21
30.4 Apparatus type of protection "tD", Practice A;
temperature tested under 500 mm dust layer, for use
in Zone 21
30.5 Apparatus type of protection "tD", Practice B for use
in Zone 22
30.6 Apparatus type of protection "tD", Practice A for use
in Zone 22
Bibliography
Annex ZA (informative) Classification of electrical apparatus
into categories
Annex ZB (normative) Normative references to international
publications with their corresponding European
publications
Annex ZZ (informative) Coverage of Essential Requirements of
EC Directives
Specifies general requirements for the design, construction, testing and marking of electrical apparatus protected by any recognized safeguard technique for use in areas where combustible dust may be present in quantities that could lead to a fire or explosion hazard.
DevelopmentNote |
Together with I.S. EN 61241-1, it supersedes I.S. EN 50281-1-1. (03/2007)
|
DocumentType |
Standard
|
Pages |
124
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 61241-0:2007 | Identical |
BS EN 61241-0:2006 | Identical |
IEC 61241-0:2004 | Identical |
EN 61241-0:2006 | Identical |
NBN EN 61241-0 : 2007 | Identical |
NF EN 61241-0 : 2007 | Identical |
DIN EN 61241-0 : 2007 | Identical |
IEC 60243-1:2013 | Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies |
EN ISO 4027:2003 | Hexagon socket set screws with cone point (ISO 4027:2003) |
EN 60192:2001 | Low pressure sodium vapour lamps - Performance specifications |
EN 20286-2 : 1993 | ISO SYSTEM OF LIMITS AND FITS - TABLES OF STANDARD TOLERANCE GRADES AND LIMIT DEVIATIONS FOR HOLES AND SHAFTS |
EN 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
EN ISO 4029:2003 | Hexagon socket set screws with cup point (ISO 4029:2003) |
IEC 60662:2011 | High-pressure sodium vapour lamps - Performance specifications |
IEC 60192:2001 | Low-pressure sodium vapour lamps - Performance specifications |
EN 60623:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
ISO 4225:1994 | Air quality General aspects Vocabulary |
IEC 60050-486:1991 | International Electrotechnical Vocabulary (IEV) - Part 486: Secondary cells and batteries |
EN ISO 4026:2003 | Hexagon socket set screws with flat point (ISO 4026:2003) |
ISO 4017:2014 | Fasteners Hexagon head screws Product grades A and B |
EN 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation |
EN ISO 4014:2011 | Hexagon head bolts - Product grades A and B (ISO 4014:2011) |
IEC 60216-2:2005 | Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria |
EN 60285:1994/A2:1999 | ALKALINE SECONDARY CELLS AND BATTERIES - SEALED NICKEL-CADMIUM CYLINDRICAL RECHARGEABLE SINGLE CELLS |
ISO 4032:2012 | Hexagon regular nuts (style 1) — Product grades A and B |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
EN 60947-3:2009/A2:2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS (IEC 60947-3:2008/A2:2015) |
ISO 4762:2004 | Hexagon socket head cap screws |
ISO 262:1998 | ISO general purpose metric screw threads — Selected sizes for screws, bolts and nuts |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
EN ISO 4028:2003 | Hexagon socket set screws with dog point (ISO 4028:2003) |
ISO 4027:2003 | Hexagon socket set screws with cone point |
EN 61241-1:2004/corrigendum Dec. 2006 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 1: PROTECTION BY ENCLOSURES "TD" |
IEC 61241-1:2004 | Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD" |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60086-1:2015 | Primary batteries - Part 1: General |
ISO 4029:2003 | Hexagon socket set screws with cup point |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60086-1:2015 | Primary batteries - Part 1: General |
ISO 4026:2003 | Hexagon socket set screws with flat point |
EN 60243-1:2013 | ELECTRIC STRENGTH OF INSULATING MATERIALS - TEST METHODS - PART 1: TESTS AT POWER FREQUENCIES (IEC 60243-1:2013) |
EN ISO 4017:2014 | Fasteners - Hexagon head screws - Product grades A and B (ISO 4017:2014) |
ISO 286-2:2010 | Geometrical product specifications (GPS) ISO code system for tolerances on linear sizes Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts |
ISO 273:1979 | Fasteners — Clearance holes for bolts and screws |
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV | Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
EN ISO 4032:2012 | Hexagon regular nuts (style 1) - Product grades A and B (ISO 4032:2012) |
IEC 61241-2-1:1994 | Electrical apparatus for use in the presence of combustible dust - Part 2: Test methods - Section 1: Methods for determining the minimum ignition temperatures of dust |
ISO 4028:2003 | Hexagon socket set screws with dog point |
EN 60662:2012 | High-pressure sodium vapour lamps - Performance specifications |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO 48:2010 | Rubber, vulcanized or thermoplastic Determination of hardness (hardness between 10 IRHD and 100 IRHD) |
IEC 60623:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells |
IEC 61150:1992 | Alkaline secondary cells and batteries - Sealed nickel-cadmium rechargeable monobloc batteries in button cell design |
ISO 178:2010 | Plastics Determination of flexural properties |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
IEC 60285:1993+AMD1:1995+AMD2:1998 CSV | Alkaline secondary cells and batteries - Sealed nickel-cadmium cylindrical rechargeable single cells |
IEC 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation |
EN 60034-5:2001/A1:2007 | ROTATING ELECTRICAL MACHINES - PART 5: DEGREES OF PROTECTION PROVIDED BY THE INTEGRAL DESIGN OF ROTATING ELECTRICAL MACHINES (IP CODE) - CLASSIFICATION |
EN ISO 4762:2004 | Hexagon socket head cap screws (ISO 4762:2004, Corrected version 2024-08) |
EN 61150 : 1993 | ALKALINE SECONDARY CELLS AND BATTERIES - SEALED NICKEL CADMIUM RECHARGEABLE MONOBLOC BATTERIES IN BUTTON CELL DESIGN |
ISO 4014:2011 | Hexagon head bolts Product grades A and B |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.