• Shopping Cart
    There are no items in your cart

I.S. EN 61241-0:2006

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 0: GENERAL REQUIREMENTS

Available format(s)

Hardcopy , PDF

Superseded date

08-09-2009

Superseded by

I.S. EN 60079-0:2012

Language(s)

English

Published date

01-01-2006

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.


Dates of withdrawal of national standards are available from NSAI.

€149.00
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Construction
    4.1 General
    4.2 Principles for design and testing of apparatus
          for use in Zone 20
    4.3 Opening enclosures
    4.4 Environmental conditions
5 Temperatures
    5.1 Maximum surface temperature
    5.2 Maximum surface temperature with respect to dust
          layers above 50 mm
    5.3 Ambient temperature
6 Enclosure materials
    6.1 Non-metallic enclosures and non-metallic parts
          of enclosures
    6.2 Enclosures containing light metals
7 Fasteners
    7.1 Access to live parts
    7.2 Compatible material
8 Interlocking devices
9 Bushings
    9.1 Prevention of turning
    9.2 Torque tests
10 Materials used for cementing
    10.1 Documentation
    10.2 Thermal stability
    10.3 Verification
11 Ex components
    11.1 General
    11.2 Mounting
    11.3 Internal mounting
    11.4 External mounting
12 Connection facilities and terminal compartments
    12.1 Attached cables
    12.2 Terminal access
    12.3 Creepage and clearance
13 Connection facilities for earthing or bonding conductors
    13.1 Internal connection
    13.2 External connection
    13.3 Facility not required
    13.4 Effective connection
    13.5 Effective contact
    13.6 Environmental
    13.7 Use of light metal
14 Cable and conduit entries
    14.1 Intended use
    14.2 Construction
    14.3 Integral part of the apparatus
    14.4 Prevention of twisting
    14.5 Method of attaching
    14.6 Blanking elements
    14.7 Branching point temperatures
15 Radiating equipment
    15.1 Lasers and other continuous wave source
    15.2 Ultrasonic sources
16 Supplementary requirements for specific electrical
    apparatus - Rotating electrical machines
    16.1 Ventilation openings for external fans
    16.2 Construction and mounting of the ventilating systems
    16.3 Clearances for the ventilating system for use
          in Zone 20 or 21
    16.4 Materials for external fans and fanhoods
17 Switchgear
    17.1 Flammable dielectric
    17.2 Interlocking
    17.3 Indication of open position
    17.4 Openings
18 Fuses
19 Plugs and sockets
    19.1 Plugs and sockets construction
    19.2 Bolted plugs and sockets
    19.3 For Zone 21 and Zone 22
    19.4 Plugs remaining energized
20 Luminaries
    20.1 Light transmitting covers
    20.2 Guards
    20.3 Mounting
    20.4 Covers
    20.5 Parts remaining energized
    20.6 Types of lamps
21 Caplights, caplamps and handlamps
    21.1 Leakage
    21.2 Separate enclosures
22 Apparatus incorporating cells and batteries
    22.1 General
    22.2 Connection of cells
    22.3 Characteristics
    22.4 Compatibility
    22.5 Limits
    22.6 Mixture of cells
    22.7 Interchangeability
    22.8 Re-charging
    22.9 Different cells
    22.10 Leakage
    22.11 Method of connection
    22.12 Orientation
    22.13 Identification of replacement
23 Verification and tests
    23.1 General
    23.2 Verification of documents
    23.3 Compliance of prototype or sample with documents
    23.4 Type tests
24 Routine verifications and tests
25 Manufacturer's responsibility
26 Verifications and tests on modified or repaired
    electrical apparatus
27 Clamping tests of cable entries for non-armoured
    and braided cables
    27.1 Cable entries with clamping by the sealing ring
    27.2 Cable entries with clamping by filling compound
    27.3 Cable entries with clamping by means of a clamping
          device
    27.4 Tensile test
    27.5 Mechanical strength
28 Clamping tests of cable entries for armoured cables
    28.1 Clamping tests where the armourings are clamped by
          a device within the gland
    28.2 Clamping tests where the armourings are not clamped
          by a device within the gland
29 Marking
    29.1 General
    29.2 Marking of all electrical apparatus
    29.3 Multiple protection techniques
    29.4 Order of marking
    29.5 Reduced marking
30 Examples of marking
    30.1 Apparatus type of protection "mD" for use in Zone 20
    30.2 Apparatus type of protection "iaD" for use in Zone 20
    30.3 Apparatus type of protection "pD" for use in Zone 21
    30.4 Apparatus type of protection "tD", Practice A;
          temperature tested under 500 mm dust layer, for use
          in Zone 21
    30.5 Apparatus type of protection "tD", Practice B for use
          in Zone 22
    30.6 Apparatus type of protection "tD", Practice A for use
          in Zone 22
Bibliography
Annex ZA (informative) Classification of electrical apparatus
         into categories
Annex ZB (normative) Normative references to international
         publications with their corresponding European
         publications
Annex ZZ (informative) Coverage of Essential Requirements of
         EC Directives

Specifies general requirements for the design, construction, testing and marking of electrical apparatus protected by any recognized safeguard technique for use in areas where combustible dust may be present in quantities that could lead to a fire or explosion hazard.

DevelopmentNote
Together with I.S. EN 61241-1, it supersedes I.S. EN 50281-1-1. (03/2007)
DocumentType
Standard
Pages
124
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
UNE-EN 61241-0:2007 Identical
BS EN 61241-0:2006 Identical
IEC 61241-0:2004 Identical
EN 61241-0:2006 Identical
NBN EN 61241-0 : 2007 Identical
NF EN 61241-0 : 2007 Identical
DIN EN 61241-0 : 2007 Identical

IEC 60243-1:2013 Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies
EN ISO 4027:2003 Hexagon socket set screws with cone point (ISO 4027:2003)
EN 60192:2001 Low pressure sodium vapour lamps - Performance specifications
EN 20286-2 : 1993 ISO SYSTEM OF LIMITS AND FITS - TABLES OF STANDARD TOLERANCE GRADES AND LIMIT DEVIATIONS FOR HOLES AND SHAFTS
EN 60216-1:2013 Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results
EN ISO 4029:2003 Hexagon socket set screws with cup point (ISO 4029:2003)
IEC 60662:2011 High-pressure sodium vapour lamps - Performance specifications
IEC 60192:2001 Low-pressure sodium vapour lamps - Performance specifications
EN 60623:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
ISO 4225:1994 Air quality General aspects Vocabulary
IEC 60050-486:1991 International Electrotechnical Vocabulary (IEV) - Part 486: Secondary cells and batteries
EN ISO 4026:2003 Hexagon socket set screws with flat point (ISO 4026:2003)
ISO 4017:2014 Fasteners Hexagon head screws Product grades A and B
EN 61241-14:2004 Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation
EN ISO 4014:2011 Hexagon head bolts - Product grades A and B (ISO 4014:2011)
IEC 60216-2:2005 Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria
EN 60285:1994/A2:1999 ALKALINE SECONDARY CELLS AND BATTERIES - SEALED NICKEL-CADMIUM CYLINDRICAL RECHARGEABLE SINGLE CELLS
ISO 4032:2012 Hexagon regular nuts (style 1) — Product grades A and B
IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
EN 60947-3:2009/A2:2015 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS (IEC 60947-3:2008/A2:2015)
ISO 4762:2004 Hexagon socket head cap screws
ISO 262:1998 ISO general purpose metric screw threads — Selected sizes for screws, bolts and nuts
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
EN ISO 4028:2003 Hexagon socket set screws with dog point (ISO 4028:2003)
ISO 4027:2003 Hexagon socket set screws with cone point
EN 61241-1:2004/corrigendum Dec. 2006 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 1: PROTECTION BY ENCLOSURES "TD"
IEC 61241-1:2004 Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 60086-1:2015 Primary batteries - Part 1: General
ISO 4029:2003 Hexagon socket set screws with cup point
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
IEC 60086-1:2015 Primary batteries - Part 1: General
ISO 4026:2003 Hexagon socket set screws with flat point
EN 60243-1:2013 ELECTRIC STRENGTH OF INSULATING MATERIALS - TEST METHODS - PART 1: TESTS AT POWER FREQUENCIES (IEC 60243-1:2013)
EN ISO 4017:2014 Fasteners - Hexagon head screws - Product grades A and B (ISO 4017:2014)
ISO 286-2:2010 Geometrical product specifications (GPS) ISO code system for tolerances on linear sizes Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts
ISO 273:1979 Fasteners — Clearance holes for bolts and screws
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units
EN ISO 4032:2012 Hexagon regular nuts (style 1) - Product grades A and B (ISO 4032:2012)
IEC 61241-2-1:1994 Electrical apparatus for use in the presence of combustible dust - Part 2: Test methods - Section 1: Methods for determining the minimum ignition temperatures of dust
ISO 4028:2003 Hexagon socket set screws with dog point
EN 60662:2012 High-pressure sodium vapour lamps - Performance specifications
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
ISO 48:2010 Rubber, vulcanized or thermoplastic Determination of hardness (hardness between 10 IRHD and 100 IRHD)
IEC 60623:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
IEC 61150:1992 Alkaline secondary cells and batteries - Sealed nickel-cadmium rechargeable monobloc batteries in button cell design
ISO 178:2010 Plastics Determination of flexural properties
IEC 60216-1:2013 Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results
IEC 60285:1993+AMD1:1995+AMD2:1998 CSV Alkaline secondary cells and batteries - Sealed nickel-cadmium cylindrical rechargeable single cells
IEC 61241-14:2004 Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation
EN 60034-5:2001/A1:2007 ROTATING ELECTRICAL MACHINES - PART 5: DEGREES OF PROTECTION PROVIDED BY THE INTEGRAL DESIGN OF ROTATING ELECTRICAL MACHINES (IP CODE) - CLASSIFICATION
EN ISO 4762:2004 Hexagon socket head cap screws (ISO 4762:2004, Corrected version 2024-08)
EN 61150 : 1993 ALKALINE SECONDARY CELLS AND BATTERIES - SEALED NICKEL CADMIUM RECHARGEABLE MONOBLOC BATTERIES IN BUTTON CELL DESIGN
ISO 4014:2011 Hexagon head bolts Product grades A and B

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.