I.S. EN 61967-2:2005
Current
The latest, up-to-date edition.
INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS, 150 KHZ TO 1 GHZ - PART 2: MEASUREMENT OF RADIATED EMISSIONS - TEM CELL AND WIDEBAND TEM CELL METHOD
Hardcopy , PDF
English
01-01-2005
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Test conditions
5.1 General
5.2 Supply voltage
5.3 Frequency range
6 Test equipment
6.1 General
6.2 Shielding
6.3 RF measuring instrument
6.4 Preamplifier
6.5 TEM cell
6.6 Wideband TEM/GTEM cell
6.7 50-Ohm termination
6.8 System gain
7 Test set-up
7.1 General
7.2 Test configuration
7.3 Test PCB
8 Test procedure
8.1 General
8.2 Ambient measurement
8.3 DUT operational check
8.4 DUT emissions measurement
9 Test report
9.1 General
9.2 Measurement conditions
10 IC emissions reference levels
Annex A (informative) Example calibration & set-up
verification sheet
Annex B (informative) TEM cell and wideband TEM cell
descriptions
B.1 TEM cell
B.2 Wideband GTEM cell
Annex C (informative) Calculation of dipole moment from
measured data
C.1 General
C.2 Dipole moment calculation
Annex D (informative) Specification of emissions data
D.1 General
D.2 Specification of emission levels
D.3 Presentation of results
D.4 Examples
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Bibliography
Specifies a method for measuring the electromagnetic radiation from an integrated circuit (IC).
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
58
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
DIN EN 61967-2:2006-03 | Identical |
SN EN 61967-2 : 2005 | Identical |
NBN EN 61967-2 : 2007 | Identical |
NF EN 61967-2 : 2006 | Identical |
BS EN 61967-2:2005 | Identical |
EN 61967-2:2005 | Identical |
IEC 61967-2:2005 | Identical |
IEC 60050-131:2002 | International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory |
CISPR 16-2-2:2010 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance power |
IEC 61967-1:2002 | Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 1: General conditions and definitions |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
CISPR 16-1-3:2004+AMD1:2016 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power |
CISPR 16-2-1:2014 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements |
CISPR 16-1-5:2014+AMD1:2016 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz |
EN 61967-1:2002 | Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 1: General conditions and definitions |
CISPR 16-2-4:2003 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-4: Methods of measurement of disturbances and immunity - Immunity measurements |
IEC 61000-4-20:2010 | Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.