SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 2: HYDRAULIC LIFTS
Hardcopy , PDF
29-01-2010
English
22-01-1999
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
Introduction
1 Scope
2 Normative references
3 Definitions
4 Units and symbols
5 Lift well
6 Machinery and pulley spaces
7 Landing doors
8 Car and balancing weight
9 Suspension, precaution against free fall, descent with
excessive speed and protection against unintended car
movement
10 Guide rails, buffers and final limit switch
11 Clearances between car and wall facing the car entrance,
and between car and balancing weight
12 Lift machine
13 Electric installations and appliances
14 Protection against electric faults; controls; priorities
15 Notices, markings and operating instructions
16 Examinations - Tests - Register - Maintenance
Annex A (normative) List of the electric safety devices
Annex B (normative) Unlocking triangle
Annex C (informative) Technical dossier
Annex D (normative) Examinations and tests before putting
into service
Annex E (informative) Periodical examinations and tests,
examinations and tests after an important modification
or after an accident
Annex F (normative) Safety components - Tests procedures for
verification of conformity
Annex G (Informative) Proof of guide rails
Annex H (normative) Electronic components - Failure exclusion
Annex J (normative) Pendulum shock tests
Annex K (normative) Calculations of rams, cylinders, rigid
pipes and fittings
Annex L (informative) Machinery spaces - Access
Annex M (informative) Description of possible measures
Annex ZA (informative) Relationship between this European
Standard and the Essential Requirements of EU
Directive 95/16/EC amended by 2006/42/EC
Defines the safety rules for the construction and installation of permanently installed new hydraulic lifts serving defined landing levels, having a car designed for the transportation of persons or persons and goods, suspended by jacks, ropes or chains and moving between guide rails inclined not more than 15 degrees to the vertical.
DevelopmentNote |
1998 Edition Re-issued in January 2010 & incorporates AMD 3 2009. (02/2010)
|
DocumentType |
Standard
|
Pages |
292
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
NS EN 81-2 : 1998 + A3 2009 | Identical |
BS EN 81-2 : 1998 | Identical |
EN 81-2 : 1998 + A3 2009 | Identical |
NBN EN 81-2 : 1998 + A3 2010 | Identical |
SN EN 81-2 : 1998 + A3 2009 | Identical |
UNI EN 81-2 : 2010 | Identical |
NF EN 81-2 : 1998 + A3 2010 | Identical |
DIN EN 81-2:2010-08 | Identical |
UNE-EN 81-2:2001 | Identical |
NEN EN 81-2 : 1998 + A3 2010 | Identical |
DIN EN 81-2:2000-05 | Identical |
ISO 6403:1988 | Hydraulic fluid power — Valves controlling flow and pressure — Test methods |
EN 294:1992/AC:1993 | SAFETY OF MACHINERY - SAFETY DISTANCES TO PREVENT DANGER ZONES BEING REACHED BY THE UPPER LIMBS |
EN 12015:2014 | Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission |
EN 12016:2013 | Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity |
EN 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements |
EN 50214:2006/corrigendum Dec. 2007 | FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES |
EN 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements |
HD 21-3 : S3 AMD 2 2008 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - NON-SHEATHED CABLES FOR FIXED WIRING |
HD 21.5 S3:1994/A2:2001 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 5: FLEXIBLE CABLES (CORDS) |
HD 214 : 200S2 | RECOMMENDED METHOD FOR DETERMINING THE COMPARATIVE TRACKING INDEX OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS |
HD 384.4.41 S2:1996/A1:2002 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 41: PROTECTION AGAINST ELECTRIC SHOCK |
EN 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures |
ISO 7465:2007 | Passenger lifts and service lifts — Guide rails for lift cars and counterweights — T-type |
EN 60249-2-3 : 1994 AMD 4 2000 | BASE MATERIALS FOR PRINTED CIRCUITS - PART 2: SPECIFICATIONS - SPECIFICATION NO. 3: EPOXIDE CELLULOSE PAPER COPPER-CLAD LAMINATED SHEET OF DEFINED FLAMMABILITY (VERTICAL BURNING TEST) |
EN 60950:2000/corrigendum:2002 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT |
HD 384.6.61 : 200S2 | ELECTRICAL INSTALLATIONS OF BUILDINGS - VERIFICATION - INITIAL VERIFICATION |
IEC 61508-5:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508) |
EN 10025:1990/A1:1993 | HOT ROLLED PRODUCTS OF NON-ALLOY STRUCTURAL STEELS - TECHNICAL DELIVERY CONDITIONS |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
EN 1050 : 1996 | SAFETY OF MACHINERY - PRINCIPLES FOR RISK ASSESSMENT |
HD 323.2.14 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST N: OF TEMPERATURE |
IEC 60747-5:1992 | Semiconductor devices - Discrete devices and integrated circuits -Part 5: Optoelectronic devices |
EN 60742:1995 | Isolating transformers and safety isolating transformers - Requirements |
HD 22-4 : 200S4 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 4: CORDS AND FLEXIBLE CABLES |
EN 60249-2-2 : 1994 AMD 5 2000 | BASE MATERIALS FOR PRINTED CIRCUITS - PART 2: SPECIFICATIONS - SPECIFICATION NO. 2: PHENOLIC CELLULOSE PAPER COPPER-CLAD LAMINATED SHEET, ECONOMIC QUALITY |
HD 21.1 : 200S4 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - GENERAL REQUIREMENTS |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems |
EN 60947-4-1 : 2010 AMD 1 2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012) |
HD 360 : S2 AMD 1 | CIRCULAR RUBBER INSULATED LIFT CABLES FOR NORMAL USE |
EN 61508-5:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels |
HD 384.5.54 : 200S1 | ELECTRICAL INSTALLATION OF BUILDINGS - SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
ISO 1219-1:2012 | Fluid power systems and components — Graphical symbols and circuit diagrams — Part 1: Graphical symbols for conventional use and data-processing applications |
EN 60068-2-29:1993 | Environmental testing - Part 2: Tests - Test Eb and guidance: Bump |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
IEC 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508) |
EN 62326-1:2002 | Printed boards - Part 1: Generic specification |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
HD 21 PT4 : 200S2 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 4: SHEATHED CABLES FOR FIXED WIRING |
EN 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations |