I.S. HD 60364-4-41:2007
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK
Hardcopy , PDF
07-07-2020
English
01-01-2007
Foreword
410 Introduction
410.1 Scope
410.2 Normative references
410.3 General requirements
411 Protective measure: automatic disconnection of supply
411.1 General
411.2 Requirements for basic protection
411.3 Requirements for fault protection
411.4 TN systems
411.5 TT systems
411.6 IT systems
411.7 Functional extra-low voltage (FELV)
412 Protective measure: double or reinforced insulation
412.1 General
412.2 Requirements for basic protection and fault protection
413 Protective measure: electrical separation
413.1 General
413.2 Requirements for basic protection
413.3 Requirements for fault protection
414 Protective measure: extra-low-voltage provided by SELV and
PELV
414.1 General
414.2 Requirements for basic protection and fault protection
414.3 Sources for SELV and PELV
414.4 Requirements for SELV and PELV circuits
415 Additional protection
415.1 Additional protection: residual current protective
devices (RCDs)
415.2 Additional protection: supplementary protective
equipotential bonding
Annex A (normative) Provisions for basic protection
(protection against direct contact)
Annex B (normative) Obstacles and placing out of reach
Annex C (normative) Protective measures for application only
when the installation is controlled or
under the supervision of skilled or
instructed persons
Annex D (informative) Correspondence between IEC 60364-4-41:2001
and IEC 60364-4-41:2005
Bibliography
Annex ZA (normative) Special national conditions
Annex ZB (informative) A-deviations
Specifies essential requirements regarding protection against electric shock, including basic protection (protection against direct contact) and fault protection (protection against indirect contact) of persons and livestock.
DevelopmentNote |
Supersedes I.S. HD 384.4.41, I.S. HD 384.4.46 and I.S. HD 384-4-47. (03/2007)
|
DocumentType |
Standard
|
Pages |
68
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
HD 60364-4-41:2017/A11:2017 | Identical |
IEC 60364-4-41:2005+AMD1:2017 CSV | Identical |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 60364-4-43:2008 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
HD 60364-5-54:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules |
IEC 60364-6:2016 | Low voltage electrical installations - Part 6: Verification |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
IEC 60146-2:1999 | Semiconductor converters - Part 2: Self-commutated semiconductor converters including direct d.c. converters |
IEC 60439-1:1999+AMD1:2004 CSV | Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies |
EN 60439-1:1999/A1:2004 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES |
IEC 62020:1998+AMD1:2003 CSV | Electrical accessories - Residual current monitors for household and similar uses (RCMs) |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 61557-9:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 61557-8:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.