• IEC 60092-353 REDLINE : 4ED 2016

    Current The latest, up-to-date edition.

    ELECTRICAL INSTALLATIONS IN SHIPS - PART 353: POWER CABLES FOR RATED VOLTAGES 1 KV AND 3 KV

    Available format(s): 

    Language(s): 

    Published date:  26-09-2016

    Publisher:  International Electrotechnical Committee

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope and object
    2 Normative references
    3 Terms and definitions
    4 General requirements
    5 Constructional requirements
    6 Tests - Methods and requirements
    Annex A (informative) - Alternative enhanced
            insulation thickness for 0,6/1 kV
    Annex B (informative) - Identification of cores
            of multicore cables
    Bibliography

    Abstract - (Show below) - (Hide below)

    Pertains to shipboard and offshore non radial field power cables with extruded solid insulation, having a voltage rating of 0,6/1 (1,2) kV or 1,8/3 (3,6) kV intended for fixed installations.

    General Product Information - (Show below) - (Hide below)

    Committee TC 18
    Development Note Stability Date: 2020. (09/2016)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60038:2009 IEC standard voltages
    IEC 60228:2004 Conductors of insulated cables
    IEC 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
    IEC 60331-2:2009 Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm
    IEC 60331-11:1999+AMD1:2009 CSV Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame temperature of at least 750 °C
    IEC 60754-1:2011 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content
    IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
    IEC 60754-2:2011 Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity
    IEC 60331-21:1999 Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV
    IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
    IEC 60331-1:2009 Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm
    IEC 60332-3-22:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A
    IEC 61034-2:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements
    IEC 60445:2017 Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors
    IEC 60092-350:2014 Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications