FOREWORD
INTRODUCTION
1 General
1.1 Scope
1.2 Normative references
2 Definitions
3 Identification and classification
3.1 Arrester identification
3.2 Arrester classification
4 Standard ratings
4.1 Standard rated voltages
4.2 Standard rated frequencies
4.3 Standard nominal discharge currents
4.4 Service conditions
5 Requirements
5.1 Insulation withstand of the arrester housing
5.2 Reference voltage
5.3 Impulse protective levels
5.4 Partial discharges
5.5 Seal leakage
5.6 Thermal stability
5.7 Long duration current impulse withstand
5.8 Operating duty
5.9 Power frequency voltage versus time characteristics
of an arrester
5.10 Short-circuit withstand
5.11 Disconnectors
5.12 Requirements for internal and external grading
components
5.13 Power frequency sparkover
5.14 Grading current
5.15 Weather ageing tests
6 General procedures
6.1 Measuring equipment and accuracy
6.2 Reference voltage measurements
6.3 Test samples
7 Type tests (design tests)
7.1 General
7.2 Insulation withstand tests on the arrester housing
7.3 Impulse protective level tests
7.4 Long duration current impulse withstand test
7.5 Operating duty tests
7.6 Tests of arrester disconnectors
7.7 Power frequency voltage sparkover tests
7.8 Moisture ingress tests
7.9 Weather ageing tests
8 Routine tests and acceptance tests
8.1 Routine tests
8.2 Acceptance tests
Annex A (normative) Abnormal service conditions
Annex B (normative) Test to verify thermal equivalency
between complete arrester and arrester section
Annex C (normative) Procedure to verify the power frequency
voltage versus time characteristics of an arrester
Annex D (normative) Artificial pollution testing of
metal-oxide surge arresters containing gapped
structures
Annex E (informative) Typical information given with
inquiries and tenders
Annex F (informative) Typical maximum protective levels
Bibliography
Figures
Tables
This standard basically applies to all metal-oxide surge arresters with gaps and housed in either porcelain or polymeric housings.This standard also specifies requirements and tests for metal-oxide surge arresters with internal series gaps,with rated voltages of 52KV and below.
Committee |
TC 37
|
DevelopmentNote |
Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
10/30210015 DC : 0 | BS EN 60099-5 - SURGE ARRESTERS - SELECTION AND APPLICATION RECOMMENDATIONS |
17/30339060 DC : 0 | BS EN 60071-2 - INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE (PROPOSED HORIZONTAL STANDARD) |
IEC 60099-5:2018 | Surge arresters - Part 5: Selection and application recommendations |
IEC 60099-5:2018 RLV | Surge arresters - Part 5: Selection and application recommendations |
CEI EN 60099-5 : 2014 | SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS |
IEC 60071-2:2018 RLV | Insulation co-ordination - Part 2: Application guidelines |
BS EN 60099-5:2013 | Surge arresters Selection and application recommendations |
EN IEC 60071-2:2018 | Insulation co-ordination - Part 2: Application guidelines |
I.S. EN IEC 60071-2:2018 | INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDELINES |
NF EN 60099-5 : 2017 | SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS |
I.S. EN 60099-5:2013 | SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS (IEC 60099-5:2013 (EQV)) |
EN IEC 60099-5:2018 | Surge arresters - Part 5: Selection and application recommendations |
16/30340451 DC : DRAFT APR 2016 | BS EN 60099-5 - SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS |
I.S. EN IEC 60099-5:2018 | SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS |
IEC 60071-2:2018 | Insulation co-ordination - Part 2: Application guidelines |
EN 60099-5:2013 | Surge arresters - Part 5: Selection and application recommendations |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 60099-1:1991+AMD1:1999 CSV | Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems |
IEC 60099-5:2013 | Surge arresters - Part 5: Selection and application recommendations |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.