IEC 60255-26:2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Measuring relays and protection equipment - Part 26: Electromagnetic compatibility requirements
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
24-01-2023
English - French
24-05-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Definition of environmental levels
5 Emission
6 Immunity
7 Test set-up and procedures
8 Criteria for acceptance
9 Test report
Annex A (normative) - Power frequency immunity tests
on binary inputs
Annex B (informative) - Background information for
power frequency tests
Annex C (normative) - Application of discharges for
electrostatic discharge test
Bibliography
IEC 60255-26:2013 is applicable to measuring relays and protection equipment, taking into account combinations of devices to form schemes for power system protection including the control, monitoring, communication and process interface equipment used with those systems. This standard specifies the requirements for electromagnetic compatibility for measuring relays and protection equipment. The requirements specified in this standard are applicable to measuring relays and protection equipment in a new condition and all tests specified are type tests only. This new edition includes the following significant technical changes with respect to the previous edition:
- definition of test specifications, test procedures and acceptance criteria per phenomena and port under test in one document;
- extension of radiated emission measurement for frequencies above 1 GHz;
- limitation of radiated emission measurement at 3 m distance for small equipment only;
- addition of zone A and zone B test level on surge test;
- extension of tests on the auxiliary power supply port by a.c. and d.c. voltage dips, a.c. component in d.c. (ripple) and gradual shut-down/start-up;
- harmonization of acceptance criteria for immunity tests.
Committee |
TC 95
|
DevelopmentNote |
Supersedes IEC 60255-22-1, IEC 60255-22-2, IEC 60255-22-3, IEC 60255-22-4, IEC 60255-22-5, IEC 60255-22-6, IEC 60255-22-7, IEC 60255-11 and IEC 60255-25. (05/2013) Stability date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
92
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
IS/IEC 60255 : Part 26 : 2013 | Identical |
NEN EN IEC 60255-26 : 2013 C11 2013 | Identical |
I.S. EN 60255-26:2013 | Identical |
PN EN 60255-26 : 2014 AC 2014 | Identical |
SAC GB/T 14598.26 : 2015 | Identical |
VDE 0435-320 : 2014 COR 2 2015 | Identical |
DIN EN 60255-26 : 2014 COR 2 2015 | Identical |
CEI EN 60255-26 : 2015 | Identical |
EN 60255-26:2013/AC:2013 | Identical |
UNE-EN 60255-26:2013 | Identical |
UNE-EN 60255-26:2010 | Identical |
BS EN 60255-26:2013 | Identical |
PNE-FprEN 60255-26 | Identical |
NBN EN 60255-26 : 2013 | Identical |
IEEE C57.12.10-2010 REDLINE | IEEE Standard Requirements for Liquid-Immersed Power Transformers |
BS EN 60255-1:2010 | Measuring relays and protection equipment Common requirements |
BS EN 62488-2:2017 | Power line communication systems for power utility applications Analogue power line carrier terminals or APLC |
17/30355564 DC : 0 | BS EN 61869-13 ED.1.0 - INSTRUMENT TRANSFORMERS - PART 13: STAND-ALONE MERGING UNIT |
BS EN 60255-27:2014 | Measuring relays and protection equipment Product safety requirements |
I.S. EN 62488-2:2017 | POWER LINE COMMUNICATION SYSTEMS FOR POWER UTILITY APPLICATIONS - PART 2: ANALOGUE POWER LINE CARRIER TERMINALS OR APLC |
EN 61000-6-5:2015/AC:2018-01 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-5: GENERIC STANDARDS - IMMUNITY FOR EQUIPMENT USED IN POWER STATION AND SUBSTATION ENVIRONMENT (IEC 61000-6-5:2015/COR1:2017) |
EN 60255-27:2014 | Measuring relays and protection equipment - Part 27: Product safety requirements |
BS EN 60255-22-3:2008 | Measuring relays and protection equipment Electrical disturbance tests. Radiated electromagnetic field immunity |
I.S. EN 61000-6-5:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-5: GENERIC STANDARDS - IMMUNITY FOR EQUIPMENT USED IN POWER STATION AND SUBSTATION ENVIRONMENT |
I.S. EN 60255-27:2014 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 27: PRODUCT SAFETY REQUIREMENTS |
IEEE C37.119-2005 | IEEE Guide for Breaker Failure Protection of Power Circuit Breakers |
IEEE C37.302-2015 | IEEE Guide for Fault Current Limiter (FCL) Testing of FCLs Rated above 1000 V AC |
PD IEC/TR 62511:2014 | Guidelines for the design of interconnected power systems |
IEC 60255-27:2013 | Measuring relays and protection equipment - Part 27: Product safety requirements |
05/30136363 DC : DRAFT JUL 2005 | IEC 60255-6 ED 3 - ELECTRICAL RELAYS - PART 6: GENERAL REQUIREMENTS FOR MEASURING RELAYS AND PROTECTION EQUIPMENT |
EN 62488-2:2017 | Power line communication systems for power utility applications - Part 2: Analogue power line carrier terminals or APLC |
CEI EN 60255-27 : 2014 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 27: PRODUCT SAFETY REQUIREMENTS |
CEI EN 60255-1 : 2011 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
UNE-EN 61000-6-5:2016 | Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for equipment used in power station and substation environment |
IEC 60255-1:1967 | Electrical relays - Part 1: Instantaneous all-or-nothing relays |
UNE-EN 60255-1:2010 | Measuring relays and protection equipment -- Part 1: Common requirements |
IEC 60255-22-3:2007 | Measuring relays and protection equipment - Part 22-3: Electrical disturbance tests - Radiated electromagnetic field immunity |
IEC TR 62511:2014 | Guidelines for the design of interconnected power systems |
BS EN 61000-6-5:2015 | Electromagnetic compatibility (EMC) Generic standards. Immunity for equipment used in power station and substation environment |
I.S. EN 60255-22-3:2008 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 22-3: ELECTRICAL DISTURBANCE TESTS - RADIATED ELECTROMAGNETIC FIELD IMMUNITY |
NF EN 60255-1 : 2010 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
I.S. EN 60255-1:2010 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
EN 60255-22-3:2008 | Measuring relays and protection equipment - Part 22-3: Electrical disturbance tests - Radiated electromagnetic field immunity |
EN 60255-1:2010 | Measuring relays and protection equipment - Part 1: Common requirements |
CAN/CSA-IEC 61000-6-5:18 | Electromagnetic compatibility (EMC) — Part 6-5: Generic standards — Immunity for equipment used in power station and substation environment (Adopted IEC 61000-6-5:2015, first edition, 2015-08) | Compatibilité électromagnétique (CEM) — Partie 6-5 : Normes génériques — Immunité pour les équipements utilisés dans les environnements de centrales électriques et de postes (norme IEC 61000-6-5:2015 adoptée, première édition, 2015-08) |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 61000-4-17:1999+AMD1:2001+AMD2:2008 CSV | Electromagnetic compatibility (EMC) - Part 4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC TS 61000-6-5:2001 | Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for power station and substation environments |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60255-1:1967 | Electrical relays - Part 1: Instantaneous all-or-nothing relays |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
IEC 61000-4-18:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.