IEC 60598-2-22:2014+AMD1:2017 CSV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
06-12-2021
English - French
22-09-2017
IEC 60598-2-22:2014+A1:2017 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1 000 V. This fourth edition cancels and replaces the third edition published in 1997, AMD1:2002 and AMD2:2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Clause 22.3, addition of definitions for PELF and Self-contained portable emergency luminaire;
b) Clause 22.5, updated with the introduction of requirements for non-replaceable lamp and batteries;
c) Clause 22.6, improved requirements to confirm that the charge indication is correctly connected to the circuit together with other clarifications regarding the controlgear and the remote box with its connecting cabe to the emergency luminaire;
d) Clause 22.12, improved requirements to ensure that the luminaire shall not become unsafe;
e) Clause 22.16, full revision of the photometric testing to align with ISO and CIE;
f) Clause 22.17, now only references the requirements which are now covered in IEC 61347 2-7;
g) Clause 22.19, now only references the requirements which are now covered in IEC 61347 2-7;
h) Annex A, now includes nickel metal hydride batteries and reference to cell types in IEC 61951-1;
i) Annex B, minor changes to the classifications;
j) Annex C, Figure C.1 deleted in favour of a revised text;
k) Annex E, the additional requirements covering self-contained portable emergency luminaires. This publication is to be read in conjunction with IEC 60598-1:2014. The contents of the corrigenda of March 2015 and April 2016 have been included in this copy. This consolidated version consists of the fourth edition (2014) and its amendment 1 (2017). Therefore, no need to order amendment in addition to this publication.
Committee |
TC 34/SC 34D
|
DevelopmentNote |
To be read in conjunction with IEC 60598-1. (04/2008) Stability Date: 2020. (09/2017)
|
DocumentType |
Standard
|
Pages |
136
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
CEI EN 60598-2-22/A1:2020 | Identical |
SS-EN IEC 60598-2-22, UTG 4:2022 | Identical |
GOST IEC 60598-2-22 : 2012 | Identical |
NBN EN 60598 2-22 : 2014 COR 2016 | Identical |
NEN EN IEC 60598-2-22 : 2014 C11 2016 | Identical |
PN EN 60598-2-22 : 2015 AC 2016 | Identical |
SN EN 60598-2-22 : 2014 | Identical |
DIN EN 60598-2-22 : 2015 COR 2 2017 | Identical |
NEN-EN-IEC 60598-2-22:2014/A1:2020 | Identical |
UNE-EN 60598-2-22:2015 | Identical |
BS EN 60598-2-22:2014 | Identical |
EN 60598-2-22:2014/AC:2016-09 | Identical |
NF EN 60598-2-22 : 2014 | Identical |
GOST R IEC 60598-2-22 : 1999 | Identical |
VDE 0711-222 : 1992 | Identical |
I.S. EN 60598-2-22:2014/A1:2020 | Identical |
VDE 0711-2-22 : 2015 COR 2 2017 | Identical |
BS EN 62722-1:2016 | Luminaire performance General requirements |
DIN EN 60924 : 1994 | D.C. SUPPLIED ELECTRONIC BALLASTS FOR TUBULAR FLUORESCENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
IEC TR 61200-704:1996 | Electrical installation guide - Part 704: Construction and demolition site installations |
09/30163250 DC : 0 | BS ISO 15370 - SHIPS AND MARINE TECHNOLOGY - LOW-LOCATION LIGHTING ON PASSENGER SHIPS - ARRANGEMENT |
08/30187424 DC : DRAFT AUG 2008 | BS EN 61347-2-7 - LAMP CONTROLGEAR - PART 2-7: PARTICULAR REQUIREMENTS FOR D.C. SUPPLIED ELECTRONIC BALLASTS FOR EMERGENCY LIGHTING |
BS EN 60335-2-29 : 2004 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-29: PARTICULAR REQUIREMENTS FOR BATTERY CHARGERS |
07/30166127 DC : 0 | |
IEC 60335-2-29:2016 RLV | Household and similar electrical appliances - Safety - Part 2-29: Particular requirements for battery chargers |
I.S. EN 60601-2-41:2009 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-41: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF SURGICAL LUMINAIRES AND LUMINAIRES FOR DIAGNOSIS |
PREN 1838 : DRAFT 2011 | LIGHTING APPLICATIONS - EMERGENCY LIGHTING |
S.R. HD 60364-5-56:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES |
EN IEC 61347-2-14:2018 | Lamp controlgear - Part 2-14: Particular requirements for DC and/or AC supplied electronic controlgear for fluorescent induction lamps |
BS EN 1838:2013 | Lighting applications. Emergency lighting |
EN 61547:2009 | Equipment for general lighting purposes - EMC immunity requirements |
EN 13032-3:2007 | Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 3: Presentation of data for emergency lighting of work places |
EN 50172:2004 | Emergency escape lighting systems |
EN 61347-2-7:2012 | Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
HD 60364-5-559:2012/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-559: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - LUMINAIRES AND LIGHTING INSTALLATIONS |
18/30373839 DC : 0 | BS EN 60601-2-41 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-41: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF SURGICAL LUMINAIRES AND LUMINAIRES FOR DIAGNOSIS |
DIN EN 60928 : 2000 | AUXILIARIES FOR LAMPS - A.C. SUPPLIED ELECTRONIC BALLASTS FOR TUBULAR FLUORESCENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
BS 5266-8(2004) : 2004 | EMERGENCY ESCAPE LIGHTING SYSTEMS |
CEI EN 61547 : 2010 | EQUIPMENT FOR GENERAL LIGHTING PURPOSES - EMC IMMUNITY REQUIREMENTS |
BS ISO 16069:2017 | Graphical symbols. Safety signs. Safety way guidance systems (SWGS) |
BS 5266-6:1999 | Emergency lighting Code of practice for non-electrical low mounted way guidance systems for emergency use. Photoluminescent systems |
16/30341843 DC : 0 | BS EN 61347-2-14 - LAMP CONTROLGEAR - PART 2-14: PARTICULAR REQUIREMENTS FOR D.C. AND/OR A.C. SUPPLIED ELECTRONIC CONTROLGEAR FOR FLUORESCENT INDUCTION LAMPS |
BS EN 50172:2004 | Emergency escape lighting systems |
I.S. EN 61347-2-3:2011 | LAMP CONTROL GEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. AND/OR D.C. SUPPLIED ELECTRONIC CONTROL GEAR FOR FLUORESCENT LAMPS |
CEI EN 62034 : 2013 | AUTOMATIC TEST SYSTEMS FOR BATTERY POWERED EMERGENCY ESCAPE LIGHTING |
ISO 30061:2007 | Emergency lighting |
BS EN 61347-2-3:2011 | Lamp control gear Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps |
I.S. EN 61547:2009 | EQUIPMENT FOR GENERAL LIGHTING PURPOSES - EMC IMMUNITY REQUIREMENTS |
CEI EN 61347-2-3 : 2012 | LAMP CONTROLGEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. AND/OR D.C. SUPPLIED ELECTRONIC CONTROL GEAR FOR FLUORESCENT LAMPS |
IEC PAS 62722-1:2011 | Luminaire performance - Part 1: General requirements |
BS EN 61347-2-7:2012 | Lamp controlgear Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
BS EN ISO 20126 : 2012 | DENTISTRY - MANUAL TOOTHBRUSHES - GENERAL REQUIREMENTS AND TEST METHODS (ISO 20126:2012) |
CCS GUIDELINE E-08 : 2017 | LUMINAIRES |
EN 60335-2-29:2004/A2:2010 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-29: PARTICULAR REQUIREMENTS FOR BATTERY CHARGERS |
NF EN 61547 : 2009 | EQUIPMENT FOR GENERAL LIGHTING PURPOSES - EMC IMMUNITY REQUIREMENTS |
IEC 60364-5-55:2011+AMD1:2012+AMD2:2016 CSV | Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment |
UNE-HD 60364-5-56:2010 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services |
BS EN 13032-3:2007 | Measurement and presentation of photometric data of lamps and luminaires Presentation of data for emergency lighting of work places |
UNE-EN 1838:2016 | Lighting applications - Emergency lighting |
I.S. EN 1838:2013 | LIGHTING APPLICATIONS - EMERGENCY LIGHTING |
DIN EN 13032-3:2007-12 | Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 3: Presentation of data for emergency lighting of work places |
VDE 0712-22 : 2000 | AUXILIARIES FOR LAMPS - A.C. SUPPLIED ELECTRONIC BALLASTS FOR TUBULAR FLUORESCENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
BS ISO 15370:2010 | Ships and marine technology. Low-location lighting (LLL) on passenger ships. Arrangement |
ISO 20126:2012 | Dentistry Manual toothbrushes General requirements and test methods |
DIN ISO 15370:2005-09 | SHIPS AND MARINE TECHNOLOGY - LOW-LOCATION LIGHTING ON PASSENGER SHIPS - ARRANGEMENT |
11/30235103 DC : 0 | BS EN 1838 - LIGHTING APPLICATIONS - EMERGENCY LIGHTING |
ISO 16069:2017 | Graphical symbols — Safety signs — Safety way guidance systems (SWGS) |
BS EN 62034:2012 | Automatic test systems for battery powered emergency escape lighting |
BS 5266-2:1998 | Emergency lighting Code of practice for electrical low mounted way guidance systems for emergency use |
08/30195114 DC : DRAFT DEC 2008 | BS EN 60335-2-29 AMD2 - HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-29: PARTICULAR REQUIREMENTS FOR BATTERY CHARGERS |
UNE-EN 61347-2-3:2012 | Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps |
I.S. HD 60364-5-559:2012 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-559: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - LUMINAIRES AND LIGHTING INSTALLATIONS (IEC 60364-5-55:2011 (MOD)) |
UNE-EN 61547:2011 | Equipment for general lighting purposes - EMC immunity requirements |
I.S. HD 60364-5-56:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES (IEC 60364-5-56:2009 (EQV)) |
DIN EN 1838:2013-10 | LIGHTING APPLICATIONS - EMERGENCY LIGHTING |
IEC 60601-2-41:2009+AMD1:2013 CSV | Medical electrical equipment - Part 2-41: Particular requirementsfor the basic safety and essential performance of surgical luminaires and luminaires for diagnosis |
UNI EN 1838 : 2013 | LIGHTING APPLICATIONS - EMERGENCY LIGHTING |
IEC 60335-2-29:2016 | Household and similar electrical appliances - Safety - Part 2-29: Particular requirements for battery chargers |
BS EN 60601-2-41 : 2009 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-41: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF SURGICAL LUMINAIRES AND LUMINAIRES FOR DIAGNOSIS |
DD IEC PAS 62722-1 : DRAFT JULY 2011 | LUMINAIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
BS EN 61547:2009 | Equipment for general lighting purposes. EMC immunity requirements |
CEI EN 50172 : 2006 | EMERGENCY ESCAPE LIGHTING SYSTEMS |
09/30201398 DC : 0 | BS EN 62034 ED.2 - AUTOMATIC TEST SYSTEMS FOR BATTERY POWERED EMERGENCY ESCAPE LIGHTING |
16/30343481 DC : 0 | BS EN 62386-220 - DIGITAL ADDRESSABLE LIGHTING INTERFACE - PART 220: PARTICULAR REQUIREMENTS FOR CONTROL GEAR - CENTRALLY SUPPLIED DC EMERGENCY OPERATION (DEVICE TYPE 19) |
UNE-EN 61347-2-7:2012 | Lamp controlgear -- Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
I.S. EN 62722-1:2016 | LUMINAIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
S.R. HD 60364-5-559:2012 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-559: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - LUMINAIRES AND LIGHTING INSTALLATIONS |
BS EN 61347-2-7:2012+A1:2019 | Lamp controlgear Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
ISO 15370:2010 | Ships and marine technology Low-location lighting (LLL) on passenger ships Arrangement |
I.S. EN 50172:2004 | EMERGENCY ESCAPE LIGHTING SYSTEMS |
I.S. EN 60335-2-29:2004 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-29: PARTICULAR REQUIREMENTS FOR BATTERY CHARGERS |
IEC 61347-2-14:2018 | Lamp controlgear - Part 2-14: Particular requirements for DC and/or AC supplied electronic controlgear for fluorescent induction lamps |
IEC 61892-3:2012 | Mobile and fixed offshore units - Electrical installations - Part 3: Equipment |
I.S. EN 62034:2012 | AUTOMATIC TEST SYSTEMS FOR BATTERY POWERED EMERGENCY ESCAPE LIGHTING (IEC 62034:2012 (EQV)) |
IEC 62034:2012 | Automatic test systems for battery powered emergency escape lighting |
IEC 61547:2009 | Equipment for general lighting purposes - EMC immunity requirements |
IEC 61347-2-3:2011+AMD1:2016 CSV | Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps |
IEC 61347-2-7:2011+AMD1:2017 CSV | Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
UNE-EN 60601-2-41:2010 | Medical electrical equipment -- Part 2-41: Particular requirements for basic safety and essential performance of surgical luminaires and luminaires for diagnosis |
UNE-EN 60335-2-29:2006 | Household and similar electrical appliances - Safety -- Part 2-29: Particular requirements for battery chargers |
EN 1838:2013 | Lighting applications - Emergency lighting |
12/30243728 DC : 0 | BS EN 62722-1 - LUMINAIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
BS 5266-7(1999) : 1999 | LIGHTING APPLICATIONS - EMERGENCY LIGHTING |
I.S. EN IEC 61347-2-14:2018 | LAMP CONTROLGEAR - PART 2-14: PARTICULAR REQUIREMENTS FOR DC AND/OR AC SUPPLIED ELECTRONIC CONTROLGEAR FOR FLUORESCENT INDUCTION LAMPS |
16/30322000 DC : 0 | BS ISO 16069 - GRAPHICAL SYMBOLS - SAFETY SIGNS - SAFETY WAY GUIDANCE SYSTEMS (SWGS) |
97/718468 DC : DRAFT OCT 1997 | ISO/CD 15370 - SHIPS AND MARINE TECHNOLOGY - LOW-LOCATION LIGHTING ON PASSENGER SHIPS - ARRANGEMENT |
CEI EN 61347-2-7 : 2012 | LAMP CONTROLGEAR - PART 2-7: PARTICULAR REQUIREMENTS FOR BATTERY SUPPLIED ELECTRONIC CONTROLGEAR FOR EMERGENCY LIGHTING (SELF-CONTAINED) |
BS IEC 61892-3:2012 | Mobile and fixed offshore units. Electrical installations Equipment |
HD 60364-5-56:2010/A12:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES |
03/320435 DC : DRAFT DEC 2003 | IEC 61347-2-7 ED.2 - SPECIFICATION FOR LAMP CONTROLGEAR - PART 2-7: PARTICULAR REQUIREMENTS FOR D.C. SUPPLIED. ELECTRONIC BALLASTS FOR EMERGENCY LIGHTING |
I.S. EN 61347-2-7:2012 | LAMP CONTROLGEAR - PART 2-7: PARTICULAR REQUIREMENTS FOR BATTERY SUPPLIED ELECTRONIC CONTROLGEAR FOR EMERGENCY LIGHTING (SELF-CONTAINED) (IEC 61347-2-7:2011 (EQV)) |
UNE-EN 62722-1:2016 | Luminaire performance - Part 1: General Requirements |
IEC 60364-5-56:2009 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services |
EN 60928:1995/A1:1999 | AUXILIARIES FOR LAMPS - A.C. SUPPLIED ELECTRONIC BALLASTS FOR TUBULAR FLUORESCENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
EN 60601-2-41:2009/A1:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-41: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF SURGICAL LUMINAIRES AND LUMINAIRES FOR DIAGNOSIS (IEC 60601-2-41:2009/A1:2013) |
EN 62722-1:2016 | Luminaire performance - Part 1: General requirements |
EN 62034:2012 | Automatic test systems for battery powered emergency escape lighting |
EN 61347-2-3:2011/A1:2017 | LAMP CONTROL GEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. AND/OR D.C. SUPPLIED ELECTRONIC CONTROL GEAR FOR FLUORESCENT LAMPS (IEC 61347-2-3:2011/A1:2016) |
CEI 18-58 : 2013 | MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT |
CSA E61347.1 :2003 | LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
CSA E61347.1 : 2003 : R2013 | LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
CSA E61347.2.3 : 2003 | LAMP CONTROLGEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. SUPPLIED ELECTRONIC BALLASTS FOR FLUORESCENT LAMP |
CSA E61347.2.3 : 2003 : INC : UPD 1 : 2012 : R200800 | LAMP CONTROLGEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. SUPPLIED ELECTRONIC BALLASTS FOR FLUORESCENT LAMP |
CSA E61347.2.3 : 2003 : INC : AMD 1 : 2005 : R2013 | LAMP CONTROLGEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. SUPPLIED ELECTRONIC BALLASTS FOR FLUORESCENT LAMP |
CSA C22.2 No. 60601.2.41 : 2011 : INC : AMD 1 : 2015 : R2016 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-41: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF SURGICAL LUMINAIRES AND LUMINAIRES FOR DIAGNOSIS |
CSA C22.2 No. 60601.2.41 : 2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-41: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF SURGICAL LUMINAIRES AND LUMINAIRES FOR DIAGNOSIS |
IEC 61347-2-3:2011+AMD1:2016 CSV | Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps |
IEC 62034:2012 | Automatic test systems for battery powered emergency escape lighting |
IEC 60364-5-56:2009 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services |
IEC 61347-2-13:2014+AMD1:2016 CSV | Lamp controlgear - Part 2-13: Particular requirements for d.c. ora.c. supplied electronic controlgear for LED modules |
IEC 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
IEC 60896-21:2004 | Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test |
ISO 30061:2007 | Emergency lighting |
IEC 61951-2:2017 | Secondary cells and batteries containing alkaline or other non acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 2: Nickel-metal hydride |
IEC 61951-1:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 1: Nickel-Cadmium |
IEC 61347-2-7:2011+AMD1:2017 CSV | Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
IEC 61056-1:2012 | General purpose lead-acid batteries (valve-regulated types) - Part 1: General requirements, functional characteristics - Methods of test |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC 61347-2-12:2005+AMD1:2010 CSV | Lamp controlgear - Part 2-12: Particular requirements for d.c. or a.c. supplied electronic ballasts for discharge lamps (excluding fluorescent lamps) |
IEC 61347-2-2:2011 | Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
ISO 3864-1:2011 | Graphical symbols Safety colours and safety signs Part 1: Design principles for safety signs and safety markings |
IEC 60155:1993 | Glow-starters for fluorescent lamps |
ISO 3864-4:2011 | Graphical symbols Safety colours and safety signs Part 4: Colorimetric and photometric properties of safety sign materials |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.