IEC 60807-1:1991
Current
The latest, up-to-date edition.
Rectangular connectors for frequencies below 3 MHz - Part 1:Generic specification - General requirements and guide for thepreparation of detail specifications for connectors with assessedquality
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
15-10-1991
FOREWORD
SECTION 1: GENERAL
Clause
1.1 Scope and object
1.2 Normative references
SECTION 2: TECHNICAL CHARACTERISTICS
2.1 Definitions
2.1.1 Connector type
2.1.2 Connector style
2.1.3 Connector variant
2.1.4 Examples
2.2 Classification into climatic categories
2.3 Creepage and clearance distances
2.4 Currents
2.5 Marking
2.5.1 On the connector
2.5.2 On the package
2.6 IEC-type designation
SECTION 3: QUALITY ASSESSMENT PROCEDURES
3.1 Primary stage of manufacture
3.2 Structurally similar rectangular connectors
3.3 System of levels
3.3.1 Performance level
3.3.2 Assessment level
3.3.3 Inspection level (IL)
3.3.4 Acceptable quality level (AQL)
3.3.5 Combination of performance and assessment levels
3.4 Grouping of tests
3.4.1 Test groups for qualification approval testing
3.4.2 Inspection groups for quality conformance
inspection
3.4.3 Delayed delivery
3.4.4 Release for delivery before completion of
Group B tests
3.4.5 Delivery of tested connectors
3.5 Approval of manufacturers, independent test
laboratories and distributors
3.6 Qualification approval procedures
3.6.1 General
3.6.2 Granting of qualification approval
3.6.3 Extent of qualification approval
3.6.4 Maintenance of qualification approval
3.6.5 Suspension or withdrawal of qualification approval
3.6.6 Significant changes
3.6.7 Qualification approval testing
3.6.8 Qualification approval test report
3.7 Quality conformance inspection
3.7.1 Formation of inspection lots
3.7.2 Small lots and/or expensive connectors
3.7.3 Quality conformance inspection groups
3.7.4 Lot-by-lot tests
3.7.5 Periodic tests
3.7.6 Certified record of released lots
3.7.7 Quality conformance testing
3.7.8 In-process testing
SECTION 4: GENERAL REQUIREMENTS, TESTS AND TEST SCHEDULES
4.1 General aspects
4.2 Preconditioning
4.3 Mounting of specimens
4.4 Test schedules
4.4.1 Basic (minimum) test schedule
4.4.2 Full test schedule
SECTION 5: PREPARATION OF DETAIL SPECIFICATIONS
5.1 Title of detail specifications
5.1.1 Drawing information
5.1.2 Contents of detail specification
Annex A (normative) - Common lettering system
Applies to rectangular connectors designed for use in equipment for telecommunication, electronic data processing and in electronic equipment or devices employing similar techniques. Should be used in conjunction with the relevant detail specification(s).
Committee |
TC 48/SC 48B
|
DevelopmentNote |
Stability Date: 2017. (10/2012)
|
DocumentType |
Standard
|
Pages |
68
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
DIN IEC 60807-1:1993-04 | Identical |
NEN IEC 60807-1 : 1999 | Identical |
CEI 48-16 : 1ED 1992 | Identical |
02/206148 DC : 0 | IEC 60603-7-5. ED. 1.0 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-5: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ (CAT 6, SHIELDED) |
IEC PAS 60603-7-3:2004 | Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz |
02/202649 DC : DRAFT JAN 2002 | IEC PAS 61076-3-111. ED.1 - CONNECTORS FOR USE IN ELECTRONIC EQUIPMENT - PART 3-111: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED AND UNSHIELDED, FREE AND FIXED CONNECTORS, FOR INDUSTRIAL ENVIRONMENTS FOR FREQUENCIES UP TO 250 MHZ |
CEI 48-20 : 1998 | RECTANGULAR CONNECTORS FOR FREQUENCIES BELOW 3 MHZ - PART 3: DETAIL SPECIFICATION FOR A RANGE OF CONNECTORS WITH TRAPEZOIDAL SHAPED METAL SHELLS AND ROUND CONTACTS - REMOVABLE CRIMP CONTACT TYPES WITH CLOSED CRIMP BARRELS, REAR INSERTION/REAR EXTRACTION |
IEC 60807-9:1993 | Rectangular connectors for frequencies below 3 MHz - Part 9: Detail specification for a range of peritelevision connectors |
BS EN 175300:1997 | Harmonized system of quality assessment for electronic components. Sectional specification:rectangular connectors for frequencies below 3 MHz |
I.S. EN 175300:1998 | RECTANGULAR CONNECTORS FOR FREQUENCIES BELOW 3 MHZ (SECTIONAL SPECIFICATION) |
ANSI C79.1:2002 | American National Standard for Nomenclature for Glass Bulbs Intended for Use with Electric Lamps |
03/100166 DC : DRAFT JAN 2003 | IEC 60603-7-5 ED.1.0 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-5: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ |
CEI 48-19 : 1998 | RECTANGULAR CONNECTORS FOR FREQUENCIES BELOW 3 MHZ - PART 2: DETAIL SPECIFICATION FOR A RANGE OF CONNECTORS, WITH ASSESSED QUALITY, WITH TRAPEZOIDAL SHAPED METAL SHELLS AND ROUND CONTACTS - FIXED SOLDER CONTACT TYPES |
IEC PAS 61076-3-111:2002 | Connectors for electronic equipment - Part 3-111: Detail specification for 8-way, shielded and unshielded, free and fixed connectors, for industrial environments for frequencies up to 250 MHz |
EN 175300:1996 | Sectional Specification: Rectangular connectors for frequencies below 3 MHz |
IEC 60512-8:1993 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 8: Connector tests (mechanical) and mechanical tests on contacts and terminations |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60512-6:1984 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 6: Climatic tests and soldering tests |
ISO 1101:2017 | Geometrical product specifications (GPS) — Geometrical tolerancing — Tolerances of form, orientation, location and run-out |
IEC 60512-5B:1981 | Second supplement |
IEC 60512-7:1993 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 7: Mechanical operating tests and sealing tests |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
ISO 286-1:2010 | Geometrical product specifications (GPS) ISO code system for tolerances on linear sizes Part 1: Basis of tolerances, deviations and fits |
IEC 60512-4:1976 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 4: Dynamic stress tests |
ISO 286-2:2010 | Geometrical product specifications (GPS) ISO code system for tolerances on linear sizes Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts |
IEC 60512-9:1992 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 9: Miscellaneous tests |
ISO 129:1985 | Technical drawings Dimensioning General principles, definitions, methods of execution and special indications |
IEC 60512-5:1992 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 5: Impact tests (free components), static load tests (fixed components), endurance tests and overload tests |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60512-3:1976 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 3: Current-carrying capacity tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.