IEC 61066:2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Thermoluminescence dosimetry systems for personal and environmental monitoring
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
01-02-2012
English - French
26-06-2006
FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Units and symbols
5 General test procedures
5.1 Basic test procedures
5.2 Test procedures to be considered for every test
6 Performance requirements: summary
7 Capability of a dosimetry system
7.1 General
7.2 Measuring range and type of radiation
7.3 Rated ranges of the influence quantities
7.4 Maximum rated measurement time t[max]
7.5 Reusability
7.6 Model function
7.7 Example for the characterization of a dosimetry system
8 Requirements in respect of the design of the dosimetry system
8.1 General
8.2 Indication of the dose value (dosimetry system)
8.3 Assignment of the dose value to the dosemeter
(dosimetry system)
8.4 Information given on the instruments (reader
and dosemeter)
8.5 Retention and removal of radioactive contamination
(dosemeter)
8.6 Algorithm to evaluate the indicated value (dosimetry
system)
8.7 Use of dosemeters in mixed radiation fields (dosimetry
system)
9 Radiation performance requirements and tests (dosimetry system)
9.1 General
9.2 Coefficient of variation
9.3 Non-linear response
9.4 Overload characteristics, after-effects, and reusability
9.5 Radiation energy and angle of incidence for H[p](10)
or H(10) dosemeters
9.6 Radiation energy and angle of incidence for H[p](0,07)
dosemeters
9.7 Radiation incidence from the side of an H[p](10) or
H[p](0,07) dosemeter
10 Additivity of the indicated value (dosimetry system)
10.1 Requirements
10.2 Method of test
10.3 Interpretation of the results
11 Environmental performance requirements and tests
11.1 General
11.2 Ambient temperature and relative humidity (dosemeter)
11.3 Light exposure (dosemeter)
11.4 Dose build up, fading, self-irradiation and response
to natural radiation (dosemeter)
11.5 Sealing (dosemeter)
11.6 Reader stability (reader)
11.7 Ambient temperature (reader)
11.8 Light exposure (reader)
11.9 Primary power supply (reader)
11.10 General interpretation of the results
12 Electromagnetic performance requirements and tests (dosimetry
system)
12.1 General
12.2 Requirements
12.3 Method of test
12.4 Interpretation of the results
13 Mechanical performance requirements and tests
13.1 General
13.2 Drop (dosemeter)
13.3 Vibration (dosemeter and reader with weight less
than 15 kg)
13.4 General interpretation of the results
14 Software, data and interfaces of the dosimetry system
14.1 General
14.2 Requirements
14.3 Method of test
15 Instruction manual
15.1 General
15.2 Specification of the technical data
16 Documentation
16.1 Type test report
16.2 Certificate issued by the laboratory performing the
type test
Annex A (normative) Confidence limits
Annex B (informative) Causal connection between readout signals,
indicated value and value of the measurand
Annex C (informative) Overview of the necessary actions that have
to be performed for a type test according
to this standard
Figures
Tables
Applies to thermoluminescence dosimetry (TLD) systems that are used for measuring the personal dose equivalents Hp(10) or Hp(0,07) or the ambient dose equivalent H*(10) for external photon or beta radiation within the dose range from 0,01 mSv to 10 Sv. Specifies general characteristics, general test procedures and performance requirements, radiation characteristics as well as environmental, electrical, mechanical, software and safety characteristics.
Committee |
TC 45/SC 45B
|
DocumentType |
Standard
|
Pages |
131
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
SAC GB/T 10264 : 1988 | Identical |
VDE 0492-3-2 : 2007 | Identical |
DIN IEC 61066 : 2007 | Identical |
NEN IEC 61066 : 2006 | Identical |
CEI 45-51 : 1997 | Identical |
GOST R IEC 1066 : 1993 | Identical |
ISO 21909:2005 | Passive personal neutron dosemeters Performance and test requirements |
UNI ISO 14146 : 2009 | RADIATION PROTECTION - CRITERIA AND PERFORMANCE LIMITS FOR THE PERIODIC EVALUATION OF PROCESSORS OF PERSONAL DOSEMETERS FOR X AND GAMMA RADIATION |
BS ISO 28057 : 2014 | DOSIMETRY WITH SOLID THERMOLUMINESCENCE DETECTORS FOR PHOTON AND ELECTRON RADIATIONS IN RADIOTHERAPY |
BS ISO 12794:2000 | Nuclear energy. Radiation protection. Individual thermoluminescence dosemeters for extremities and eyes |
UNI ISO 12794 : 2010 | NUCLEAR ENERGY - RADIATION PROTECTION - INDIVIDUAL THERMOLUMINESCENCE DOSEMETERS FOR EXTREMITIES AND EYES |
12/30241725 DC : 0 | BS ISO 28057 - DOSIMETRY WITH SOLID THERMOLUMINSCENCE DETECTORS FOR PHOTON AND ELECTRON RADIATIONS IN RADIOTHERAPY |
ISO 14146:2000 | Radiation protection Criteria and performance limits for the periodic evaluation of processors of personal dosemeters for X and gamma radiation |
ISO 28057:2014 | Dosimetry with solid thermoluminescence detectors for photon and electron radiations in radiotherapy |
IEC 60050-394:2007 | International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors |
ISO 4037-4:2004 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields |
ISO 6980-2:2004 | Nuclear energy — Reference beta-particle radiation — Part 2: Calibration fundamentals related to basic quantities characterizing the radiation field |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
ISO 6980:1996 | Reference beta radiations for calibrating dosemeters and dose-rate meters and for determining their response as a function of beta-radiation energy |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
ISO 12794:2000 | Nuclear energy Radiation protection Individual thermoluminescence dosemeters for extremities and eyes |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
ISO 8529-3:1998 | Reference neutron radiations — Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence |
ISO 4037-2:1997 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
ISO 8529-2:2000 | Reference neutron radiations Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60904-3:2016 | Photovoltaic devices - Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data |
ISO 4037-1:1996 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods |
ISO 8529-1:2001 | Reference neutron radiations Part 1: Characteristics and methods of production |
IEC 60359:2001 | Electrical and electronic measurement equipment - Expression of performance |
ISO 4037-3:1999 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence |
IEC 60050-300:2001 | International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument |
IEC 60050-393:2003 | International Electrotechnical Vocabulary (IEV) - Part 393: Nuclear instrumentation - Physical phenomena and basic concepts |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.