IEC 61238-1:2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV) - Part 1: Test methods and requirements
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
08-05-2018
English - French, Spanish, Castilian
09-05-2003
FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Definitions
4 Symbols
5 General
5.1 Conductor
5.2 Connectors and tooling
5.3 Range of approval
6 Electrical tests
6.1 Installation
6.2 Measurements
6.3 Heat cycle test
6.4 Assessment of results
6.5 Requirements
7 Mechanical tests
7.1 Method
7.2 Requirements
8 Test report
Annex A (normative) Equalizers and their preparation
Annex B (normative) Measurements
Annex C (informative) Recommendations to improve accuracy
of measurement
Annex D (informative) Determination of the value of the
short-circuit-current
Annex E (normative) Calculation method
Annex F (informative) Explanation of the calculation method
Annex G (informative) Explanation of the temperature profile
Annex H (informative) Explanation of the statistical method
of assessing results of tests on
electrical connectors
Applies to compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV), e.g. buried cables or cables installed in buildings, having - conductors complying with IEC 60228 and IEC 60228A with cross-sectional areas 10 mm2 and greater for copper and 16 mm2 and greater for aluminium, - a maximum continuous conductor temperature not exceeding 90 °C. This standard is not applicable to connectors for overhead conductors, which are designed for special mechanical requirements, or to separable connectors with a sliding contact or multi-core connectors (i.e. ring connectors). Although it is not possible to define precisely the service conditions for all applications, two broad classes of connectors have been identified. Class A These are connectors intended for electricity distribution or industrial networks in which they can be subjected to short-circuits of relatively high intensity and duration. As a consequence, Class A connectors are suitable for the majority of applications. Class B These are connectors for networks in which overloads or short-circuits are rapidly cleared by the installed protective devices, e.g. fast-acting fuses. Depending on the application, the connectors are subjected to the following tests: Class A: heat cycle and short-circuit tests. Class B: heat cycle tests only. The object of this standard is to define the type test methods and requirements, which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. Formerly, approval for such products has been achieved on the basis of national standards and specifications and/or the demonstration of satisfactory service performance. The publication of this IEC standard does not invalidate existing approvals. However, products approved according to these earlier standards or specifications cannot claim approval to this IEC standard unless specifically tested to it. After they have been made, these tests need not be repeated unless changes are made in the connector material, design or manufacturing process which might affect the performance characteristics. Significant technical changes with respect to the previous edition are as follows: - The scope is now restricted to connectors to be used on power cables for rated voltages up to 30 kV (Um = 36 kV); - The concept of direct measurement of resistance has been introduced as an alternative to the indirect measurement, with associated tolerances; - Temperature limits have been given for insulation piercing connectors, depending on the type of cable insulation; - For short-circuit tests, tolerances have been given on the duration and recommendations have been given for large cross-sections; - Some approval criteria have been revised and harmonized between mechanical connectors and compression connectors; - The information to be included in the test report has been added; - Informative annexes have been added, with information on measuring accuracy, the calcul-ation method, the temperature profile and the statistical method.
Committee |
TC 20
|
DevelopmentNote |
Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
115
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
Supersedes |
Standards | Relationship |
NEN EN IEC 61238-1 : 2003 | Identical |
VDE 0220-100 : 2004 | Identical |
DIN EN 61238-1 : 2004 | Identical |
BS EN 61238-1:2003 | Identical |
I.S. EN 61238-1:2003 | Identical |
EN 61238-1:2003 | Identical |
NF EN 61238-1 : 2003 | Identical |
CEI EN 61238-1 : 2004 | Identical |
UNE-EN 61238-1:2006 | Identical |
I.S. HD 629-2:2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
BS EN 50393:2015 | Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV |
08/30194268 DC : 0 | BS EN 61439-5 - LOW-VOLTAGE SWITCHGEAR AND CONTROL GEAR ASSEMBLIES - PART 5: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR POWER DISTRIBUTION IN PUBLIC NETWORKS |
BS EN 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV) |
17/30355856 DC : 0 | BS EN 60947-2 AMENDMENT 1 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: CIRCUIT-BREAKERS |
UNE-EN 50393:2015 | Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV |
EN 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV) |
EN 50483-5:2009 | Test requirements for low voltage aerial bundled cable accessories - Part 5: Electrical ageing test |
BS 7888-4.1(2006) : 2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
NF EN 50483-6 : 2009 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 6: ENVIRONMENTAL TESTING |
I.S. EN 45510-2-9:2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
BS EN 50483-1:2009 | Test requirements for low voltage aerial bundled cable accessories Generalities |
CEI EN 50483-1 : 2011 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 1: GENERALITIES |
I.S. EN 61442:2005 | TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV) |
HD 629.1 S2:2006/A1:2008 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
IEC 60502-4:2010 | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (U<sub>m</sub> = 1,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) - Part 4: Test requirements on accessories for cables with rated voltages from 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
DIN EN 50153 : 2018 | RAILWAY APPLICATIONS - ROLLING STOCK - PROTECTIVE PROVISIONS RELATING TO ELECTRICAL HAZARDS |
VDE 0115-2 : 2018 | RAILWAY APPLICATIONS - ROLLING STOCK - PROTECTIVE PROVISIONS RELATING TO ELECTRICAL HAZARDS |
CEI EN 50483-5 : 2011 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 5: ELECTRICAL AGEING TEST |
I.S. EN 50153:2014 | RAILWAY APPLICATIONS - ROLLING STOCK - PROTECTIVE PROVISIONS RELATING TO ELECTRICAL HAZARDS |
I.S. HD 629.1:2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3.6/6(7.2) KV UP TO 20.8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
EN 45510-2-9:2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
CEI EN 61442 : 2006 | TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV) |
NFC 33 051 : 96 AMD 1 1998 XP | INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SCREENED SEPARABLE CONNECTORS AND ASSOCIATED DEVICES FOR RATED VOLTAGES FROM 6/10 (12) KV UP TO 18/30 (36) KV |
04/30125747 DC : DRAFT NOV 2004 | IEC 60439-5 ED.2 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 5: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR POWER DISTRIBUTION IN PUBLIC NETWORKS |
12/30262193 DC : 0 | BS EN 50393 - TEST METHODS AND REQUIREMENTS FOR ACCESSORIES FOR USE ON DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1,0 (1,2) KV |
I.S. EN 50483-5:2009 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 5: ELECTRICAL AGEING TEST |
CEI R020-001 : 2002 | COMPRESSION AND MECHANICAL CONNECTORS FOR POWER CABLES WITH COPPER OR ALUMINIUM CONDUCTORS - COMPRESSION TERMINAL LUGS FOR POWER CABLES TO FIT EQUIPMENT UP TO AND INCLUDING 1 KV - OVERALL DIMENSIONS |
BS EN 50483-5:2009 | Test requirements for low voltage aerial bundled cable accessories Electrical ageing test |
UNE-EN 50483-1:2013 | Test requirements for low voltage aerial bundled cable accessories -- Part 1: Generalities |
I.S. EN 50483-1:2009 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 1: GENERALITIES |
NF EN 50483-5 : 2009 | TEST REQUIREMENTS FOR LOW VOLTAGE AERIAL BUNDLED CABLE ACCESSORIES - PART 5: ELECTRICAL AGEING TEST |
EN 50153 : 2014 AMD 1 2017 | RAILWAY APPLICATIONS - ROLLING STOCK - PROTECTIVE PROVISIONS RELATING TO ELECTRICAL HAZARDS |
IEC 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) |
EN 45510-2-9 : 2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
EN 50393:2015 | Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV |
PREN 50393 : DRAFT 2012 | TEST METHODS AND REQUIREMENTS FOR ACCESSORIES FOR USE ON DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1,0 (1,2) KV |
NF EN 61442 : 2005 | TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (UM = 7,2 KV) UP TO 36 KV (UM = 42 KV) |
I.S. EN 50393:2015 | TEST METHODS AND REQUIREMENTS FOR ACCESSORIES FOR USE ON DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1,0 (1,2) KV |
HD 629.2 S2:2006/A1:2008 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
BS EN 45510-2-9:2008 | Guide for procurement of power station equipment Electrical equipment. Cabling systems |
BS 7888-4.2(2006) : 2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
EN 50483-1:2009 | Test requirements for low voltage aerial bundled cable accessories - Part 1: Generalities |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60493-1:2011 | Guide for the statistical analysis of ageing test data - Part 1: Methods based on mean values of normally distributed test results |
IEC 60949:1988 | Calculation of thermally permissible short-circuit currents, taking into account non-adiabatic heating effects |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
IEC 60228A:1982 | First supplement - Conductors of insulated cables - Guide to the dimensional limits of circular conductors |
BS 4579-3:1976 | Specification for performance of mechanical and compression joints in electric cable and wire connectors Mechanical and compression joints in aluminium conductors |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
CEI 20-28 : 1ED 1998 | CONNETTORI PER CAVI D'ENERGIA |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.