IEC 61270-1:1996
Current
The latest, up-to-date edition.
Capacitors for microwave ovens - Part 1: General
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
23-08-1996
Foreword
Clause
1 General
1.1 Scope and object
1.2 Normative references
2 Definitions
3 Service conditions
3.1 Altitude
3.2 Pollution
3.3 Operating temperature
3.4 Damp heat severity
4 Safety and construction
4.1 Safety
4.2 Terminations
4.3 Creepage distances and clearances
4.4 Temperature dependence of the capacitance
4.5 Capacitance tolerance
4.6 Voltage
4.7 Load capacity
4.8 Marking
5 Tests
5.1 General
5.2 Test conditions
5.3 Nature of tests
5.4 Type tests
5.5 Routine tests
5.6 Visual examination
5.7 Capacitance measurement
5.8 Voltage tests
5.9 Voltage test between the terminals
5.10 Voltage test between terminals and case
5.11 Voltage test between capacitor elements
5.12 Test of internal discharge device
5.13 Endurance test
5.14 Mechanical and climatic tests
6 Environmental protection
Annex A Information on tests on components made of
insulating material (i.e. insulators)
Applies to capacitors for microwave ovens operating at rated a.c. voltages of up to 3 000 V and a superimposed d.c. voltage of up to 1.13 times the value of rated a.c. voltage. Relates specifically to capacitors with a metal case and an upper rated maximum temperature of up to 100 °C, non-self-healing, with metal foil electrodes and dielectrics of paper and/or plastic, impregnated with a suitable oil. This part contains uniform rules regarding performance, testing and rating and specific safety rules.
DevelopmentNote |
Also numbered as BS EN 61270-1 (11/2005) Stability Date: 2020. (09/2017)
|
DocumentType |
Standard
|
Pages |
39
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NF EN 61270-1 : 1997 | Identical |
GOST IEC 61270-1 : 2013 | Identical |
NEN 11270-1 : 1997 | Identical |
I.S. EN 61270-1:1999 | Identical |
PN EN 61270-1 : 2000 | Identical |
SN EN 61270-1 : 1996 | Identical |
DIN EN 61270-1 : 1997 | Identical |
VDE 0560-22 : 1997 | Identical |
BIS IS 15406-1 : 2003 | Identical |
CEI EN 61270-1 : 1997 | Identical |
EN 61270-1:1996 | Identical |
UNE-EN 61270-1:1998 | Identical |
BS EN 60335-2-90 : 2006 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-90: PARTICULAR REQUIREMENTS FOR COMMERCIAL MICROWAVE OVENS |
I.S. EN 61071:2007 | CAPACITORS FOR POWER ELECTRONICS |
02/209094 DC : 0 | IEC 60335-2-XXX - HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-XXX: PARTICULAR REQUIREMENTS FOR COMMERCIAL MICROWAVE APPLIANCES WITH INSERTION OR CONTACTING APPLICATORS |
BS EN 60110-1:1998 | Power capacitors for induction heating installations General |
EN 60110-1:1998 | Power capacitors for induction heating installations - Part 1: General |
I.S. EN 60110-1:2003 | POWER CAPACITORS FOR INDUCTION HEATING INSTALLATIONS - PART 1: GENERAL |
CEI EN 60871-1 : 2015 | SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 1000 V - PART 1: GENERAL |
EN 60335-2-90:2006/A1:2010 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-90: PARTICULAR REQUIREMENTS FOR COMMERCIAL MICROWAVE OVENS |
BS EN 61071:2007 | Capacitors for power electronics |
CEI EN 60110-1 : 1999 | POWER CAPACITORS FOR INDUCTION HEATING INSTALLATIONS - PART 1: GENERAL |
IEC 61071:2017 | Capacitors for power electronics |
IEC 60871-1:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General |
I.S. EN 60871-1:2014 | SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 1000 V - PART 1: GENERAL |
11/30240547 DC : 0 | BS EN 60335-2-110 ED 1 - HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-110: PARTICULAR REQUIREMENTS FOR COMMERCIAL MICROWAVE APPLIANCES WITH INSERTION OR CONTACTING APPLICATORS |
CEI EN 61071 : 2007 | CAPACITORS FOR POWER ELECTRONICS |
BS EN 60871-1:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V General |
I.S. EN 60335-2-90:2006 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-90: PARTICULAR REQUIREMENTS FOR COMMERCIAL MICROWAVE OVENS |
IEC 61071:2017 RLV | Capacitors for power electronics |
EN 61071:2007 | Capacitors for power electronics |
EN 60871-1:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General |
CSA C60871.1 : 2014 | SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 1000 V - PART 1: GENERAL |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60335-2-25:2010+AMD1:2014+AMD2:2015 CSV | Household and similar electrical appliances - Safety - Part 2-25: Particular requirements for microwave ovens, including combinationmicrowave ovens |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.