IEC 61557-1:2007
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-12-2021
English - French, Spanish, Castilian
29-01-2007
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
4.1 Operating uncertainty (B), percentage operating
uncertainty (B[%])
4.2 Rated operating conditions
4.3 Battery check facility
4.4 Terminals
4.5 Class of protection
4.6 Class of pollution
4.7 Overvoltage category
4.8 Measuring category
4.9 Electromagnetic compatibility
4.10 Vibration test
5 Marking and operating instructions
5.1 Marking
5.2 Operating instructions
6 Tests
6.1 Influence of position
6.2 Influence of temperature
6.3 Influence of the supply voltage
6.4 Battery check facility
6.5 Protection class
6.6 Terminals
6.7 Mechanical requirements
6.8 Marking and operating instructions
Bibliography
This part of IEC 61557 specifies the general requirements for measuring and monitoring equipment for testing the electrical safety in low voltage distribution systems with nominal voltages up to 1 000 V a.c. and 1 500 V d.c. When measuring equipment or measuring installations involve measurement tasks of various measuring equipment covered by this series of standards, then the part of this series of standards relevant to each of the measurement tasks is applicable. This second edition replaces and cancels the first edition published in 1997. It constitutes a technical revision. The following changes were made with respect to the previous edition: a) revision of the definitions; b) addition of influence quantities E9 and E10; c) the subclause on Electromagnetic compatibility was complemented; d) inclusion of performance monitoring devices in the introduction; e) addition of new requirements for operating instructions.
Committee |
TC 85
|
DevelopmentNote |
Stability Date: 2017. (10/2012)
|
DocumentType |
Standard
|
Pages |
33
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
OVE/ONORM EN 61557-1 : 2008 | Identical |
NEN EN IEC 61557-1 : 2007 | Identical |
PN EN 61557-1 : 2009 | Identical |
SAC GB/T 18216.1 : 2000 | Identical |
VDE 0413-1 : 2007 | Identical |
BIS IS/IEC 61557-1 : 2007(R2017) | Identical |
BS EN 61557-1:2007 | Identical |
EN 61557-1:2007 | Identical |
BS EN 61850-7-1:2011 | Identical |
I.S. EN 61557-1:2007 | Identical |
UNE-EN 61557-1:2007 | Identical |
NF EN 61557-1 : 2007 | Identical |
DIN EN 61557-1 : 2007 | Identical |
CEI EN 61557-1 : 2008 | Identical |
SN EN 61557-1 : 2007 | Identical |
BS EN 61557-2:2007 | Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Insulation resistance |
BS EN 61326-2-4:2013 | Electrical equipment for measurement, control and laboratory use. EMC requirements Particular requirements. Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
04/30122740 DC : DRAFT SEP 2004 | IEC 60974-4 - ARC WELDING EQUIPMENT - PART 4: SAFETY, MAINTENANCE AND INSPECTION OF ARC WELDING EQUIPMENT IN USE |
09/30214359 DC : 0 | BS EN 50533 - RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
CEI EN 61557-3 : 2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 3: LOOP IMPEDANCE |
BS EN 50533 : 2011 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
NF EN 61557-16 : 2015 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 16: EQUIPMENT FOR TESTING THE EFFECTIVENESS OF THE PROTECTIVE MEASURES OF ELECTRICAL EQUIPMENT AND/OR MEDICAL ELECTRICAL EQUIPMENT |
04/30125199 DC : DRAFT NOV 2004 | IEC 61557-6 ED.2 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. V D.C. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 6: RESIDUAL CURRENT DEVICES (RCD) IN TT AND TN SYSTEMS |
BS EN 62353:2014 | Medical electrical equipment. Recurrent test and test after repair of medical electrical equipment |
I.S. EN 61557-7:2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1 000 V A.C. AND 1 500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 7: PHASE SEQUENCE |
I.S. EN 61557-16:2015 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 16: EQUIPMENT FOR TESTING THE EFFECTIVENESS OF THE PROTECTIVE MEASURES OF ELECTRICAL EQUIPMENT AND/OR MEDICAL ELECTRICAL EQUIPMENT |
CEI EN 61557-14 : 2014 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 14: EQUIPMENT FOR TESTING THE SAFETY OF ELECTRICAL EQUIPMENT OF MACHINERY |
NF EN 61557-12 : 2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD) |
I.S. EN 61557-10:2013 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 10: COMBINED MEASURING EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES (IEC 61557-10:2013 (EQV)) |
07/30159711 DC : 0 | BS EN 61557-11 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 11: EFFECTIVENESS OF RESIDUAL CURRENT MONITORS (RCMS) TYPE A AND TYPE B IN TT, TN AND IT SYSTEMS |
04/30125208 DC : DRAFT NOV 2004 | IEC 61557-8 ED.2 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. V D.C. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 8: INSULATION MONITORING DEVICES FOR IT SYSTEMS |
BS EN 61557-11:2009 | Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c.. Equipment for testing, measuring or monitoring of protective measures Effectiveness of residual current monitors (RCMs) type A and type B in TT, TN and IT systems |
EN 61557-14:2013 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 14: Equipment for testing the safety of electrical equipment of machinery |
EN 61557-3:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance |
EN 61557-10:2013 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring or monitoring of protective measures |
EN 61010-2-033 : 2012 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 2-033: PARTICULAR REQUIREMENTS FOR HAND-HELD MULTIMETERS AND OTHER METERS, FOR DOMESTIC AND PROFESSIONAL USE, CAPABLE OF MEASURING MAINS VOLTAGE (IEC 61010-2-033:2012) |
EN 61557-15:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems |
EN 61557-11:2009 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 11: Effectiveness of residual current monitors (RCMs) type A and type B in TT, TN and IT systems |
EN 62353:2014 | Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment |
OVE/ONORM EN 61557-12 : 2009 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD) |
15/30328086 DC | BS EN 61557-12. Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures. Part 12. Power metering and monitoring devices (PMD) |
04/30125189 DC : DRAFT NOV 2004 | IEC 61557-4 ED.2 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. V D.C. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 4: RESISTANCE OF EARTH CONNECTION AND EQUIPOTENTIAL BONDING |
I.S. EN 61010-2-033:2012 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 2-033: PARTICULAR REQUIREMENTS FOR HAND-HELD MULTIMETERS AND OTHER METERS, FOR DOMESTIC AND PROFESSIONAL USE, CAPABLE OF MEASURING MAINS VOLTAGE (IEC 61010-2-033:2012 (EQV)) |
IEC 61557-12:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD) |
BS EN 61557-6:1998 | Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring ormonitoring of protective measures Residual current devices (RCD) in TT, TN and IT systems |
PD IEC/TS 62786:2017 | Distributed energy resources connection with the grid |
NF EN 61557-11 : 2009 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 11: EFFECTIVENESS OF RESIDUAL CURRENT MONITORS (RCMS) TYPE A AND TYPE B IN TT, TN AND IT SYSTEMS |
10/30219049 DC : 0 | BS EN 62638 - RECURRENT TEST AND TEST AFTER REPAIR AND MODIFICATION OF ELECTRICAL EQUIPMENT |
BS EN 61557-7:2007 | Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Phase sequence |
BS EN 61557-5:2007 | Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Resistance to earth |
DIN EN 61557-4 : 2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 4: RESISTANCE OF EARTH CONNECTION AND EQUIPOTENTIAL BONDING |
UNE-EN 61557-12:2010 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures -- Part 12: Performance measuring and monitoring devices (PMD) |
CEI EN 61557-13 : 2012 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 13: HAND-HELD AND HAND-MANIPULATED CURRENT CLAMPS AND SENSORS FOR MEASUREMENT OF LEAKAGE CURRENTS IN ELECTRICAL DISTRIBUTION SYSTEMS |
I.S. EN 62353:2014 | MEDICAL ELECTRICAL EQUIPMENT - RECURRENT TEST AND TEST AFTER REPAIR OF MEDICAL ELECTRICAL EQUIPMENT |
I.S. EN 61557-4:2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 4: RESISTANCE OF EARTH CONNECTION AND EQUIPOTENTIAL BONDING |
I.S. EN 61557-9:2015 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS |
I.S. EN 61557-2:2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 2: INSULATION RESISTANCE |
I.S. EN 61557-5:2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 5: RESISTANCE TO EARTH |
IEC 62353:2014 | Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment |
IEC 61010-2-033:2012 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters, for domestic and professional use, capable of measuring mains voltage |
EN 61557-8:2015/AC:2016-06 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
DIN EN 61557-7 : 2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 7: PHASE SEQUENCE |
OVE/ONORM EN 61557-6 : 2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 6: EFFECTIVENESS OF RESIDUAL CURRENT DEVICES (RCD) IN TT, TN AND IT SYSTEMS |
CEI EN 61557-11 : 2013 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 11: EFFECTIVENESS OF RESIDUAL CURRENT MONITORS (RCMS) TYPE A AND TYPE B IN TT, TN AND IT SYSTEMS |
UNE-EN 61557-13:2012 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 13: Hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems |
BIS IS/IEC 62353 : 2007 | MEDICAL ELECTRICAL EQUIPMENT - RECURRENT TEST AND TEST AFTER REPAIR OF MEDICAL ELECTRICAL EQUIPMENT |
04/30125178 DC : DRAFT NOV 2004 | IEC 61557-2 ED.2 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. V D.C. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 2: INSULATION RESISTANCE |
NF EN 61557-4 : 2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 4: RESISTANCE OF EARTH CONNECTION AND EQUIPOTENTIAL BONDING |
12/30262863 DC : 0 | BS EN 61557-16 - ELECTRICAL SAFETY IN DISTRIBUTION SYSTEMS UP TO 1000 V A.C AND 1500 V D.C - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 16: EQUIPMENT FOR TESTING THE SAFETY OF ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL EQUIPMENT ACCORDING TO IEC 62638 AND IEC 62353 |
IEC TS 62786:2017 | Distributed energy resources connection with the grid |
10/30236436 DC : 0 | BS EN 61557-10 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. - AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 10: COMBINED MEASURING EQUIPMENT FOR TESTING, MEASURING AND MONITORING OF PROTECTIVE MEASURES |
NF EN 61557-7 : 2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 7: PHASE SEQUENCE |
UNE-EN 62353:2015 | Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment |
I.S. EN 61557-14:2013 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1 000 V A.C. AND 1 500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 14: EQUIPMENT FOR TESTING THE SAFETY OF ELECTRICAL EQUIPMENT OF MACHINERY (IEC 61557-14:2013 (EQV)) |
CEI EN 61557-4 : 2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 4: RESISTANCE OF EARTH CONNECTION AND EQUIPOTENTIAL BONDING |
NF EN 61557-13 : 2012 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 13: HAND-HELD AND HAND-MANIPULATED CURRENT CLAMPS AND SENSORS FOR MEASUREMENT OF LEAKAGE CURRENTS IN ELECTRICAL DISTRIBUTION SYSTEMS |
I.S. EN 61326-2-4:2013 | ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - EMC REQUIREMENTS - PART 2-4: PARTICULAR REQUIREMENTS - TEST CONFIGURATIONS, OPERATIONAL CONDITIONS AND PERFORMANCE CRITERIA FOR INSULATION MONITORING DEVICES ACCORDING TO IEC 61557-8 AND FOR EQUIPMENT FOR INSULATION FAULT LOCATION ACCORDING TO IEC 61557-9 (IEC 61326-2-4:2012 (EQV)) |
I.S. EN 61557-12:2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD) |
CEI EN 61557-7 : 2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 7: PHASE SEQUENCE |
I.S. EN 61557-3:2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 3: LOOP IMPEDANCE |
UNE-EN 61557-8:2016 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
IEC 61557-3:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance |
IEC 61557-2:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance |
04/30125185 DC : DRAFT NOV 2004 | IEC 61557-3 ED.2 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. V D.C. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 3: LOOP IMPEDANCE |
DIN EN 61557-5 : 2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 5: RESISTANCE TO EARTH |
NF EN 61557-2 : 2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 2: INSULATION RESISTANCE |
13/30250915 DC : 0 | BS EN 62353 - MEDICAL ELECTRICAL EQUIPMENT - RECURRENT TEST AND TEST AFTER REPAIR OF MEDICAL ELECTRICAL EQUIPMENT |
10/30216301 DC : 0 | BS EN 61557-14 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C AND 1500 V D.C. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 14: EQUIPMENT FOR TESTING THE SAFETY OF ELECTRICAL EQUIPMENT FOR MACHINERY |
BS EN 61557-13:2011 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems |
BS EN 61557-3:2007 | Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Loop impedance |
BS EN 61557-16:2015 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment |
17/30364658 DC : 0 | BS EN 61010-2-033 ED.2.0 - SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORYUSE - PART 2-033: PARTICULAR REQUIREMENTS FOR HAND-HELD MULTIMETERS AND OTHER METERS; FOR DOMESTIC AND PROFESSIONAL USE; CAPABLE OF MEASURING MAINS VOLTAGE |
CEI EN 61557-5 : 2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 5: RESISTANCE TO EARTH |
04/30125193 DC : DRAFT NOV 2004 | IEC 61557-5 ED.2 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. V D.C. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 5: RESISTANCE TO EARTH |
04/30125204 DC : DRAFT NOV 2004 | IEC 61557-7 ED.2 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. V D.C. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 7: PHASE SEQUENCE |
I.S. EN 50533:2011 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
NF EN 61557-5 : 2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 5: RESISTANCE TO EARTH |
DIN EN 61557-2 : 2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 2: INSULATION RESISTANCE |
CEI EN 61557-12 : 2013 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD) |
CEI EN 61557-2 : 2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 2: INSULATION RESISTANCE |
I.S. EN 61557-8:2015 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 8: INSULATION MONITORING DEVICES FOR IT SYSTEMS |
I.S. EN 61557-13:2011 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 13: HAND-HELD AND HAND-MANIPULATED CURRENT CLAMPS AND SENSORS FOR MEASUREMENT OF LEAKAGE CURRENTS IN ELECTRICAL DISTRIBUTION SYSTEMS (IEC 61557-13:2011 (EQV)) |
IEC 61557-4:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding |
IEC 61557-10:2013 | Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring and monitoring of protective measures |
12/30228018 DC : 0 | BS EN 61557-15 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 15: FUNCTIONAL SAFETY REQUIREMENTS FOR INSULATION MONITORING DEVICES AND FOR EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS |
IEC 61557-8:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
IEC 61326-2-4:2012 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
UNE-EN 61557-11:2010 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 11: Effectiveness of residual current monitors (RCMs) type A and type B in TT, TN and IT systems |
IEC 61557-9:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems |
IEC 61557-15:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems |
IEC 61557-7:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence |
IEC 61557-13:2011 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 13: Hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems |
IEC 61557-11:2009 | Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 11: Effectiveness of residual current monitors (RCMs) type A and type B in TT, TN and IT systems |
IEC 61557-6:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems |
IEC 61557-16:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment |
EN 61557-13:2011 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 13: Hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems |
BS EN 61557-4:2007 | Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Resistance of earth connection and equipotential bonding |
UNE-EN 61010-2-033:2012 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters, for domestic and professional use, capable of measuring mains voltage |
UNE-EN 50533:2012 | Railway applications - Three-phase train line voltage characteristics. |
BS EN 61557-10:2013 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Combined measuring equipment for testing, measuring or monitoring of protective measures |
BS EN 61557-12:2008 | Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Performance measuring and monitoring devices (PMD) |
CSA C22.2 No. 61010-2-033 : 2014 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 2-033: PARTICULAR REQUIREMENTS FOR HAND-HELD MULTIMETERS AND OTHER METERS, FOR DOMESTIC AND PROFESSIONAL USE, CAPABLE OF MEASURING MAINS VOLTAGE |
CEI EN 61557-8 : 2016 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 8: INSULATION MONITORING DEVICES FOR IT SYSTEMS |
08/30180629 DC : 0 | BS EN 61557-13 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 13: HAND-HELD AND HAND-MANIPULATED CURRENT CLAMPS AND SENSORS FOR MEASUREMENT OF LEAKAGE CURRENTS IN ELECTRICAL DISTRIBUTION SYSTEMS |
I.S. EN 61557-11:2009 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 11: EFFECTIVENESS OF RESIDUAL CURRENT MONITORS (RCMS) TYPE A AND TYPE B IN TT, TN AND IT SYSTEMS |
CEI EN 61557-10 : 2014 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 10: COMBINED MEASURING EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES |
PREN 50533 : DRAFT 2009 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
DIN EN 61557-3 : 2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 3: LOOP IMPEDANCE |
BS EN 61557-14:2013 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for testing the safety of electrical equipment of machinery |
BS EN 61010-2-033:2012 | Safety requirements for electrical equipment for measurement, control, and laboratory use Particular requirements for hand-held multimeters and other meters, for domestic and professional use, capable of measuring mains voltage |
EN 61326-2-4:2013 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
NF EN 61557-3 : 2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 3: LOOP IMPEDANCE |
NF EN 61557-6 : 2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 6: EFFECTIVENESS OF RESIDUAL CURRENT DEVICES (RCD) IN TT, TN AND IT SYSTEMS |
I.S. EN 61557-15:2014 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 15: FUNCTIONAL SAFETY REQUIREMENTS FOR INSULATION MONITORING DEVICES IN IT SYSTEMS AND EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS |
CEI EN 61557-6 : 2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 6: EFFECTIVENESS OF RESIDUAL CURRENT DEVICES (RCD) IN TT, TN AND IT SYSTEMS |
I.S. EN 61557-6:2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 6: EFFECTIVENESS OF RESIDUAL CURRENT DEVICES (RCD) IN TT, TN AND IT SYSTEMS |
BS EN 61557-8:2015 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Insulation monitoring devices for IT systems |
12/30274733 DC : 0 | BS EN 61557-8 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 8: INSULATION MONITORING DEVICES FOR IT SYSTEMS |
12/30274737 DC : 0 | BS EN 61557-9 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS |
IEC 61557-14:2013 | Electrical safety in low voltage distribution systems up to 1 000 V a.c and 1 500 V d.c - Equipment for testing,measuring or monitoring of protective measures - Part 14: Equipment for testing the safety of electrical equipment for machinery |
BS EN 61557-9:2015 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for insulation fault location in IT systems |
BS EN 61557-15:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems |
IEC 61557-5:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth |
EN 61557-7:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence |
EN 61557-5:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth |
EN 61557-12:2008 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD) |
EN 61557-9:2015/AC:2017-02 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS (IEC 61557-9:2014/COR2:2017) |
EN 61557-2:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance |
EN 61557-16:2015 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment |
EN 61557-4:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding |
EN 50533 : 2011 AMD 1 2016 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
EN 61557-6:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems |
IEC 61557-5:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth |
IEC 60038:2009 | IEC standard voltages |
IEC 61326-2-4:2012 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
IEC 61557-10:2013 | Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring and monitoring of protective measures |
IEC 61010-2-030:2017 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for equipment having testing or measuring circuits |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 61557-2:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance |
IEC 60364-6:2016 | Low voltage electrical installations - Part 6: Verification |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61326-2-2:2012 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems |
IEC 60359:2001 | Electrical and electronic measurement equipment - Expression of performance |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 61557-4:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding |
IEC 61557-9:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems |
IEC 61557-7:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence |
IEC 61557-8:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
IEC 61557-6:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60050-300:2001 | International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument |
IEC 61557-3:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.