IEC 62930:2017
Current
The latest, up-to-date edition.
Electric cables for photovoltaic systems with a voltage rating of 1,5 kV DC
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
13-12-2017
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Rated voltage
5 Requirements for the construction of cables
6 Marking
7 Requirements for completed cables
Annex A (normative) - Guide to use
Annex B (normative) - Requirements for insulation
and sheathing materials
Annex C (normative) - Cold impact test
Annex D (normative) - Dynamic penetration test
Annex E (normative) - Weathering/UV resistance test
Bibliography
IEC 62930:2017(E) applies to single-core cross-linked insulated power cables with cross-linked sheath. These cables are for use at the direct current (DC) side of photovoltaic systems, with a rated DC voltage up to and including 1,5 kV between conductors and between conductor and earth. This document includes halogen free low smoke cables and cables that can contain halogens.
The cables are suitable to be used with Class II equipment as defined in IEC 61140.
The cables are designed to operate at a normal continuous maximum conductor temperature of 90 °C. The permissible period of use at a maximum conductor temperature of 120 °C is limited to 20 000 h.
Committee |
TC 20
|
DevelopmentNote |
Stability Date: 2023. (12/2017)
|
DocumentType |
Standard
|
Pages |
27
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
IEC 60811-501:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds |
ISO 4892-1:2016 | Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance |
IEC 60245-2:1994+AMD1:1997+AMD2:1997 CSV | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 2: Test methods |
IEC 60811-507:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials |
IEC 60811-506:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths |
IEC 60364-7-712:2017 | Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60811-505:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths |
IEC 60811-503:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths |
IEC 60811-504:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths |
IEC 60227-2:1997+AMD1:2003 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 2: Test methods |
IEC 60811-401:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven |
IEC 60216-2:2005 | Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria |
IEC 62821-2:2015 | Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 2: Test methods |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60719:1992 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
IEC 62821-1:2015 | Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 1: General requirements |
IEC 62230:2006+AMD1:2013 CSV | Electric cables - Spark-test method |
ISO 4892-2:2013 | Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps |
IEC 60811-404:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 61034-2:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements |
IEC 62440:2008 | Electric cables with a rated voltage not exceeding 450/750 V - Guide to use |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
IEC 60811-403:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds |