IEC TR 60092-370:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical installations in ships - Part 370: Guidance on the selection of cables for telecommunication and data transfer including radio-frequency cables
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-12-2021
English
14-07-2009
FOREWORD
INTRODUCTION
1 Scope
2 Terms and definitions
3 Selection of cables
4 Fundamental considerations
5 Constructional considerations
5.1 Selection of conductor
5.2 Selection of insulation
5.3 Cable elements
5.4 Selection of screen, core screen or shield
5.5 Selection of outer protection
5.6 Selection of metallic sheath (covering), braid or armour
6 Marking
7 Guidance on the selection of appropriate tests
8 Guide to use
8.1 Introduction
8.2 General
8.3 Voltage rating
8.3.1 Data and telecommunication cables
8.3.2 High-frequency radio communications cables
8.4 Current ratings
8.5 Thermal considerations
8.6 Size of conductors
8.7 Radius of bend
8.8 Tensile stress
8.9 Compression
8.10 Mechanical damage
8.11 Electromagnetic interference
8.12 Terminations
8.13 Joints
9 Performance in a fire
Annex A (informative) - Table of tests
Bibliography
IEC/TR 60092-370:2009(E) Technical Report gives guidance and lays down the basic recommendations for the selection and installation of shipboard and offshore unit cables intended for electrical systems used in both essential and non-essential analogue or digital signal communication, transmission and control networks, including types suitable for high-frequency signals (i.e. signals with a frequency of more than 105 Hz). These cables are not suitable for direct connection to low impedance supplies. Where such cables are required, attention is drawn to IEC 60092-353.
Committee |
TC 18/SC 18A
|
DevelopmentNote |
Supersedes IEC 60092-3. (03/2010) Stability Date: 2015. (10/2012)
|
DocumentType |
Technical Report
|
ISBN |
978-2-88910-054-5
|
Pages |
18
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
CEI 18-65 : 2013 | Identical |
BS IEC 60533:2015 | Electrical and electronic installations in ships. Electromagnetic compatibility (EMC). Ships with a metallic hull |
IEC 60533:2015 | Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull |
IEC 60533:2015 RLV | Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull |
IEC 60038:2009 | IEC standard voltages |
IEC 60332-3-25:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category D |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60189-1:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 1: General test and measuring methods |
IEC 60092-352:2005 | Electrical installations in ships - Part 352: Choice and installation of electrical cables |
IEC 61156-5-1:2009 | Multicore and symmetrical pair/quad cables for digital communications - Part 5-1: Symmetrical pair/quad cables with transmission characteristics up to 1 000 MHz - Horizontal floor wiring - Blank detail specification |
IEC 60092-504:2016 | Electrical installations in ships - Part 504: Automation, control and instrumentation |
IEC 60754-1:2011 | Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content |
IEC 60096-0-1:2012+AMD1:2017 CSV | Radio frequency cables - Part 1- 0: Guide to the design of detail specifications - Coaxial cables |
IEC 60332-1-1:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulatedwire or cable - Apparatus |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60092-376:2017 | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
IEC 61892-2:2012 | Mobile and fixed offshore units - Electrical installations - Part 2: System design |
IEC 60092-201:1994 | Electrical installations in ships - Part 201: System design - General |
IEC 60092-351:2004 | Electrical installations in ships - Part 351: Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables |
IEC 60092-353:2016 | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
IEC 60754-2:2011 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
IEC 61156-1:2007+AMD1:2009 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification |
IEC 60533:2015 | Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull |
IEC 60189-2:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 2: Cables in pairs, triples, quads and quintuples for inside installations |
IEC 61892-4:2007 | Mobile and fixed offshore units - Electrical installations - Part 4: Cables |
IEC 61156-5:2009+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Horizontal floorwiring - Sectional specification |
IEC 60092-359:1987+AMD1:1994+AMD2:1999 CSV | Electrical installations in ships - Part 359: Sheathing materials for shipboard power and telecommunication cables |
IEC 60092-101:1994+AMD1:1995 CSV | Electrical installations in ships - Part 101: Definitions and general requirements |
IEC 60092-401:1980 | Electrical installations in ships - Part 401: Installation and test of completed installation |
IEC 60332-3-22:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A |
IEC 61034-2:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements |
IEC 60092-350:2014 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
IEC 60092-503:2007 | Electrical installations in ships - Part 503: Special features - AC supply systems with voltages in the range of above 1 kV up to and including 15 kV |
IEC 60189-3:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 3: Equipment wires with solid or stranded conductor wires, PVC insulated, in singles, pairs and triples |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.