• There are no items in your cart

IEC TR 62039:2007

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Selection guide for polymeric materials for outdoor use under HV stress

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

24-08-2021

Superseded by

IEC TR 62039:2021

Language(s)

English

Published date

13-03-2007

€83.17
Excluding VAT

Presents the important material properties for polymeric materials used in outdoor insulation and, where applicable, lists the standardised test methods including the minimum requirements. If no standardised tests are available, then test methods reported in literature are summarised. This report is valid for insulating materials used in outdoor high voltage electrical applications with a system voltage greater than 1000 V a.c. having polymeric insulation including also such applications where the housing is an integral part of the devices e.g. in surge arrestors and cable terminations. The scope of this report is limited to the materials only. The performance of insulators in service depends on several factors such as the type of material, the design, environmental conditions etc. Consequently, the choice of materials that fulfil the requirements listed below is a necessary condition but does not guarantee satisfactory performance when used in outdoor insulation

Committee
TC 112
DevelopmentNote
Stability Date: 2017. (11/2012)
DocumentType
Technical Report
Pages
14
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
SAC GB/Z 28818 : 2012 Identical
PD IEC/TR 62039:2007 Identical
NEN NPR IEC/TR 62039 : 2007 Identical
NBR IEC/TR 62039 : 2010 Identical

CEI EN 61462 : 2008 COMPOSITE HOLLOW INSULATORS - PRESSURIZED AND UNPRESSURIZED INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGE GREATER THAN 1000 V - DEFINITIONS, TEST METHODS, ACCEPTANCE CRITERIA AND DESIGN RECOMMENDATIONS
CEI 36-43 : 2011 SELECTION AND DIMENSIONING OF HIGH-VOLTAGE INSULATORS INTENDED FOR USE IN POLLUTED CONDITIONS - PART 3: POLYMER INSULATORS FOR A.C. SYSTEMS
DD IEC/TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Definitions, information and general principles
I.S. EN 61462:2007 COMPOSITE HOLLOW INSULATORS - PRESSURIZED AND UNPRESSURIZED INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGE GREATER THAN 1 000 V - DEFINITIONS, TEST METHODS, ACCEPTANCE CRITERIA AND DESIGN RECOMMENDATIONS
CEI 36-41 : 2011 SELECTION AND DIMENSIONING OF HIGH-VOLTAGE INSULATORS INTENDED FOR USE IN POLLUTED CONDITIONS - PART 1: DEFINITIONS, INFORMATION AND GENERAL PRINCIPLES
EN 60505:2011/AC:2017-03 EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS (IEC 60505:2011/COR1:2017)
BS EN 61462:2007 Composite hollow insulators. Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1000 V. Definitions, test methods, acceptance criteria and design recommendations
CLC/TR 62662:2011 Guidance for production, testing and diagnostics of polymer insulators with respect to brittle fracture of core materials
I.S. EN 60505:2011 EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS
IEC TS 60815-3:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems
PD CLC/TR 62662:2011 Measurement procedures for materials used in photovoltaic modules Encapsulants. Test procedure of optical durability
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
BS PD IEC/TR 62662 : 2010 GUIDANCE FOR PRODUCTION, TESTING AND DIAGNOSTICS OF POLYMER INSULATORS WITH RESPECT TO BRITTLE FRACTURE OF CORE MATERIALS
BS EN 60505:2011 Evaluation and qualification of electrical insulation systems
DD IEC/TS 60815-3:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Polymer insulators for a.c. systems
CEI CLC/TR 62662 : 2012 GUIDANCE FOR PRODUCTION, TESTING AND DIAGNOSTICS OF POLYMER INSULATORS WITH RESPECT TO BRITTLE FRACTURE OF CORE MATERIALS
CEI EN 60505 : 2012 EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS
IEC TR 62662:2010 Guidance for production, testing and diagnostics of polymer insulators with respect to brittle fracture of core materials
IEC 60505:2011 Evaluation and qualification of electrical insulation systems
EN 61462:2007 Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations
S.R. CLC/TR 62662:2011 GUIDANCE FOR PRODUCTION, TESTING AND DIAGNOSTICS OF POLYMER INSULATORS WITH RESPECT TO BRITTLE FRACTURE OF CORE MATERIALS (IEC/TR 62662:2010)

IEC 60243-1:2013 Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies
IEC 60250:1969 Recommended methods for the determination of the permittivity and dielectric dissipation factor of electrical insulating materials at power, audio and radio frequencies including metre wavelengths
IEC 60455-2:2015 Resin based reactive compounds used for electrical insulation - Part 2: Methods of test
IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
IEC 61621:1997 Dry, solid insulating materials - Resistance test to high-voltage, low-current arc discharges
IEC 61109:2008 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
ISO 11359-2:1999 Plastics Thermomechanical analysis (TMA) Part 2: Determination of coefficient of linear thermal expansion and glass transition temperature
ISO 34-1:2015 Rubber, vulcanized or thermoplastic Determination of tear strength Part 1: Trouser, angle and crescent test pieces
ISO 11357-2:2013 Plastics Differential scanning calorimetry (DSC) Part 2: Determination of glass transition temperature and glass transition step height
IEC 60093:1980 Methods of test for volume resistivity and surface resistivity of solid electrical insulating materials
ISO 4892-3:2016 Plastics — Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps
IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
ISO 4892-4:2013 Plastics — Methods of exposure to laboratory light sources — Part 4: Open-flame carbon-arc lamps
ISO 62:2008 Plastics Determination of water absorption
ISO 4892-2:2013 Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps
IEC 60587:2007 Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion
IEC 61006:2004 Electrical insulating materials - Methods of test for the determination of the glass transition temperature

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.