ISO 16017-2:2003 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. It is applicable to indoor, ambient and workplace air.
ISO 16017-2:2003 is applicable to a wide range of VOCs, including hydrocarbons, halogenated hydrocarbons, ester, glycol ethers, ketones and alcohols. A number of sorbents are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. Very polar compounds generally require derivatisation; very low boiling compounds are only partially retained by the sorbents and can only be estimated qualitatively. Semi-volatile compounds are fully retained by the sorbents, but may only be partially recovered.
ISO 16017-2:2003 is applicable to the measurement of airborne vapours of VOCs in a concentration range of approximately 0,002 mg/m3 to 100 mg/m3 individual organic for an exposure time of 8 h, or 0,3 g/m3 to 300 g/m3 individual organic for an exposure time of four weeks.
The upper limit of the useful range is set by the sorptive capacity of the sorbent used and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sorbent tubes. Artefacts are typically sub-nanogram for well-conditioned Tenax GR and carbonaceous sorbents, carbonized molecular sieves and pure charcoals; at low nanogram levels for Tenax TA and at 5 ng to 50 ng levels for other porous polymers.
Committee |
ISO/TC 146/SC 6
|
DevelopmentNote |
Supersedes ISO/DIS 16017-2. (05/2003)
|
DocumentType |
Standard
|
Pages |
35
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Standards | Relationship |
GOST R ISO 16017-2 : 2007 | Identical |
NF EN ISO 16017-2 : 2003 | Identical |
NBN EN ISO 16017-2 : 2003 | Identical |
NEN EN ISO 16017-2 : 2003 | Identical |
UNE-EN ISO 16017-2:2004 | Identical |
NS EN ISO 16017-2 : 1ED 2003 | Identical |
I.S. EN ISO 16017-2:2003 | Identical |
PN EN ISO 16017-2 : 2008 | Identical |
SN EN ISO 16017-2 : 2003 | Identical |
UNI EN ISO 16017-2 : 2004 | Identical |
SS-EN ISO 16017-2 : 2003 | Identical |
BS EN ISO 16017-2:2003 | Identical |
EN ISO 16017-2:2003 | Identical |
DIN EN ISO 16017-2:2003-09 | Identical |
DIN ISO 16000-18:2012-01 | Indoor air - Part 18: Detection and enumeration of moulds - Sampling by impaction (ISO 16000-18:2011 + Cor.1:2011) |
BS ISO 16000-25:2011 | Indoor air Determination of the emission of semi-volatile organic compounds by building products. Micro-chamber method |
DIN ISO 16000-6:2012-11 | Indoor air - Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA? sorbent, thermal desorption and gas chromatography using MS or MS-FID (ISO 16000-6:2011) |
06/30155808 DC : DRAFT SEP 2006 | BS EN 13999-4 - ADHESIVES - SHORT-TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES |
12/30263496 DC : 0 | BS ISO 12219-5 - INTERIOR AIR OF ROAD VEHICLES - PART 5: SCREENING METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - STATIC CHAMBER METHOD |
DIN ISO 16000-28:2012-12 | Indoor air - Part 28: Determination of odour emissions from building products using test chambers (ISO 16000-28:2012) |
BS ISO 16000-16:2008 | Indoor air Detection and enumeration of moulds. Sampling by filtration |
03/306295 DC : DRAFT APR 2003 | EN 14662-4 - AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 4: DIFFUSIVE SAMPLING FOLLOWED BY THERMAL DESORPTION AND GAS CHROMATOGRAPHY |
BS ISO 16000-29:2014 | Indoor air Test methods for VOC detectors |
DIN ISO 12219-3:2013-12 | Interior air of road vehicles - Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Micro-scale chamber method (ISO 12219-3:2012) |
ISO 16000-13:2008 | Indoor air — Part 13: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Collection on sorbent-backed filters |
ISO 16000-14:2009 | Indoor air — Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry |
ISO 16000-25:2011 | Indoor air Part 25: Determination of the emission of semi-volatile organic compounds by building products Micro-chamber method |
ISO 12219-2:2012 | Interior air of road vehicles — Part 2: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials — Bag method |
BS EN 13528-3:2003 | Ambient air quality. Diffusive samplers for the determination of concentrations of gases and vapours. Requirements and test methods Guide to selection, use and maintenance |
BS EN ISO 16000-7:2007 | Indoor air Sampling strategy for determination of airborne asbestos fibre concentrations |
BS EN 14662-4:2005 | Ambient air quality. Standard method for measurement of benzene concentrations Diffusive sampling followed by thermal desorption and gas chromatography |
I.S. EN 13999-4:2007 | ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES |
I.S. EN 838:2010 | WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS |
EN 13528-3:2003 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 3: Guide to selection, use and maintenance |
DIN ISO 12219-2:2012-11 | Interior air of road vehicles - Part 2: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Bag method (ISO 12219-2:2012) |
DIN ISO 16000-25:2012-01 | Indoor air - Part 25: Determination of the emission of semi-volatile organic compounds by building products - Micro-chamber method (ISO 16000-25:2011) |
DIN ISO 16000-3:2013-01 | Indoor air - Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air - Active sampling method (ISO 16000-3:2011) |
DIN ISO 12219-1:2013-12 | Interior air of road vehicles - Part 1: Whole vehicle test chamber - Specification and method for the determination of volatile organic compounds in cabin interiors (ISO 12219-1:2012) |
DIN ISO 16000-17:2010-06 | Indoor air - Part 17: Detection and enumeration of moulds - Culture-based method (ISO 16000-17:2008) |
BS ISO 12219-2:2012 | Interior air of road vehicles Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials. Bag method |
03/306296 DC : DRAFT APR 2003 | EN 14662-5 - AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 5: DIFFUSIVE SAMPLING FOLLOWED BY SOLVENT DESORPTION AND GAS CHROMATOGRAPHY |
ISO 16000-4:2011 | Indoor air Part 4: Determination of formaldehyde Diffusive sampling method |
DIN ISO 16000-13:2010-03 | Indoor air - Part 13: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Collection on sorbent-backed filters (ISO 16000-13:2008) |
ISO 16000-3:2011 | Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method |
BS ISO 16000-18:2011 | Indoor air Detection and enumeration of moulds. Sampling by impaction |
ISO 16000-15:2008 | Indoor air — Part 15: Sampling strategy for nitrogen dioxide (NO2) |
DIN EN ISO 16000-15:2009-04 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
UNI EN 838 : 2010 | WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS |
VDI 4300 Blatt 9:2005-08 | Measurement of indoor air pollution - Measurement strategy for carbon dioxide (CO) |
UNI EN ISO 16000-15 : 2008 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
BS ISO 12219-4:2013 | Interior air of road vehicles Method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials. Small chamber method |
10/30209057 DC : 0 | BS ISO 16000-6 - INDOOR AIR - PART 6: DETERMINATION OF VOLATILE ORGANIC COMPOUNDS IN INDOOR AND TEST CHAMBER AIR BY ACTIVE SAMPLING ON TENAX TA SORBENT, THERMAL DESORPTION AND GAS CHROMATOGRAPHY USING MS/FID |
BS ISO 16000-8:2007 | Indoor air Determination of local mean ages of air in buildings for characterizing ventilation conditions |
BS ISO 12219-3:2012 | Interior air of road vehicles Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials. Micro-scale chamber method |
ASTM D 7758 : 2017 : REDLINE | Standard Practice for Passive Soil Gas Sampling in the Vadose Zone for Source Identification, Spatial Variability Assessment, Monitoring, and Vapor Intrusion Evaluations |
08/30172873 DC : DRAFT JULY 2008 | BS EN 838 - WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS |
BS ISO 12219-5:2014 | Interior air of road vehicles Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials. Static chamber method |
BS EN ISO 16000-15:2008 | Indoor air Sampling strategy for nitrogen dioxide (NO2) |
BS ISO 16000-6:2011 | Indoor air Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID |
BS ISO 16000-17:2008 | Indoor air Detection and enumeration of moulds. Culture-based method |
I.S. EN 15759-2:2018 | CONSERVATION OF CULTURAL HERITAGE - INDOOR CLIMATE - PART 2: VENTILATION MANAGEMENT FOR THE PROTECTION OF CULTURAL HERITAGE BUILDINGS AND COLLECTIONS |
ISO 12219-4:2013 | Interior air of road vehicles — Part 4: Method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials — Small chamber method |
EN 15759-2:2018 | Conservation of cultural heritage - Indoor climate - Part 2: Ventilation management for the protection of cultural heritage buildings and collections |
ISO 16000-7:2007 | Indoor air — Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations |
EN ISO 16000-15:2008 | Indoor air - Part 15: Sampling strategy for nitrogen dioxide (NO2) (ISO 16000-15:2008) |
UNI EN 13999-4 : 2009 | ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES |
DIN ISO 16000-8:2008-12 | INDOOR AIR - PART 8: DETERMINATION OF LOCAL MEAN AGES OF AIR IN BUILDINGS FOR CHARACTERIZING VENTILATION CONDITIONS |
BS ISO 12219-1:2012 | Indoor air of road vehicles Whole vehicle test chamber. Specification and method for the determination of volatile organic compounds in cabin interiors |
BS ISO 16000-28:2012 | Indoor air Determination of odour emissions from building products using test chambers |
16/30332593 DC : 0 | BS EN 15759-2 - CONSERVATION OF CULTURAL HERITAGE - INDOOR CLIMATE - PART 2: VENTILATION TO PROTECT HERITAGE BUILDINGS AND COLLECTIONS |
BS ISO 16000-14:2009 | Indoor air Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs). Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry |
BS ISO 16000-3:2011 | Indoor air Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air. Active sampling method |
DIN ISO 12219-5:2014-10 | INTERIOR AIR OF ROAD VEHICLES - PART 5: SCREENING METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - STATIC CHAMBER METHOD (ISO 12219-5:2014) |
DIN ISO 12219-5 E : 2014 | INTERIOR AIR OF ROAD VEHICLES - PART 5: SCREENING METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - STATIC CHAMBER METHOD (ISO 12219-5:2014) |
ISO 12219-3:2012 | Interior air of road vehicles — Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials — Micro-scale chamber method |
ISO 12219-1:2012 | Interior air of road vehicles Part 1: Whole vehicle test chamber Specification and method for the determination of volatile organic compounds in cabin interiors |
ISO 16000-8:2007 | Indoor air Part 8: Determination of local mean ages of air in buildings for characterizing ventilation conditions |
ISO 16000-28:2012 | Indoor air Part 28: Determination of odour emissions from building products using test chambers |
ISO 12219-5:2014 | Interior air of road vehicles — Part 5: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials — Static chamber method |
DIN EN 13999-4:2009-08 | ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES |
DIN EN 838:2010-05 | Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods |
ISO 16000-17:2008 | Indoor air — Part 17: Detection and enumeration of moulds — Culture-based method |
BS EN 13999-4 : 2007 | ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES |
ISO 16000-18:2011 | Indoor air Part 18: Detection and enumeration of moulds Sampling by impaction |
BS EN 838:2010 | Workplace exposure. Procedures for measuring gases and vapours using diffusive samplers. Requirements and test methods |
BS EN ISO 16000-5:2007 | Indoor air Sampling strategy for volatile organic compounds (VOCs) |
ISO 16000-16:2008 | Indoor air — Part 16: Detection and enumeration of moulds — Sampling by filtration |
EN 14662-4:2005 | Ambient air quality - Standard method for measurement of benzene concentrations - Part 4: Diffusive sampling followed by thermal desorption and gas chromatography |
EN ISO 16000-7:2007 | Indoor air - Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations (ISO 16000-7:2007) |
EN ISO 16000-5:2007 | Indoor air - Part 5: Sampling strategy for volatile organic compounds (VOCs) (ISO 16000-5:2007) |
EN 838:2010 | Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods |
EN 13999-4:2007+A1:2009 | Adhesives - Short term method for measuring the emission properties of low-solvent or solvent-free adhesives after application - Part 4: Determination of volatile diisocyanates |
DIN ISO 16000-29:2015-02 | INDOOR AIR - PART 29: TEST METHODS FOR VOC DETECTORS (ISO 16000-29:2014) |
DIN ISO 16000-4:2012-11 | INDOOR AIR - PART 4: DETERMINATION OF FORMALDEHYDE - DIFFUSIVE SAMPLING METHOD (ISO 16000-4:2011) |
I.S. EN ISO 16000-15:2008 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
BS ISO 16000-13:2008 | Indoor air Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs). Collection on sorbent-backed filters |
DIN ISO 12219-4:2013-12 | INTERIOR AIR OF ROAD VEHICLES - PART 4: METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - SMALL CHAMBER METHOD (ISO 12219-4:2013) |
DIN ISO 16000-16:2009-12 | Indoor air - Part 16: Detection and enumeration of moulds - Sampling by filtration (ISO 16000-16:2008) |
BS ISO 16000-4:2011 | Indoor air Determination of formaldehyde. Diffusive sampling method |
DIN ISO 16000-14:2012-03 | Indoor air - Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry (ISO 16000-14:2009) |
ISO 16000-6:2011 | Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID |
I.S. EN ISO 16000-5:2007 | INDOOR AIR - PART 5: SAMPLING STRATEGY FOR VOLATILE ORGANIC COMPOUNDS (VOCS) |
ISO 16000-29:2014 | Indoor air — Part 29: Test methods for VOC detectors |
ISO 16000-5:2007 | Indoor air Part 5: Sampling strategy for volatile organic compounds (VOCs) |
DIN EN 14662-4:2005-08 | AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 4: DIFFUSIVE SAMPLING FOLLOWED BY THERMAL DESORPTION AND GAS CHROMATOGRAPHY |
DIN EN ISO 16000-7:2007-11 | Indoor air - Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations (ISO 16000-7:2007) |
DIN EN ISO 16000-5:2007-05 | Indoor air - Part 5: Sampling strategy for volatile organic compounds (VOCs) (ISO 16000-5:2007) |
VDI 2119 Blatt 4:1997-08 | Measurement of Particulate Precipitations - Microscopic differentiation and size fractionated determination of particle deposition on adhesive collection plates - Sigma-2 sampler |
EN 838:2010 | Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
EN 13528-1:2002 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 1: General requirements |
EN 13528-2:2002 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 2: Specific requirements and test methods |
ISO 6145-5:2009 | Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 5: Capillary calibration devices |
ISO 16000-1:2004 | Indoor air — Part 1: General aspects of sampling strategy |
ISO 6145-4:2004 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 4: Continuous syringe injection method |
ISO 6145-3:1986 | Gas analysis Preparation of calibration gas mixtures Dynamic volumetric methods Part 3: Periodic injections into a flowing gas stream |
ISO 6145-1:2003 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 1: Methods of calibration |
ISO 6141:2015 | Gas analysis Contents of certificates for calibration gas mixtures |
ISO 6145-6:2017 | Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.