ISO 16017-2:2003

Current

Current

The latest, up-to-date edition.

Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 2: Diffusive sampling

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English, French

Published date

16-05-2003

€165.00
Excluding VAT

ISO 16017-2:2003 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. It is applicable to indoor, ambient and workplace air.

ISO 16017-2:2003 is applicable to a wide range of VOCs, including hydrocarbons, halogenated hydrocarbons, ester, glycol ethers, ketones and alcohols. A number of sorbents are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. Very polar compounds generally require derivatisation; very low boiling compounds are only partially retained by the sorbents and can only be estimated qualitatively. Semi-volatile compounds are fully retained by the sorbents, but may only be partially recovered.

ISO 16017-2:2003 is applicable to the measurement of airborne vapours of VOCs in a concentration range of approximately 0,002 mg/m3 to 100 mg/m3 individual organic for an exposure time of 8 h, or 0,3 g/m3 to 300 g/m3 individual organic for an exposure time of four weeks.

The upper limit of the useful range is set by the sorptive capacity of the sorbent used and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sorbent tubes. Artefacts are typically sub-nanogram for well-conditioned Tenax GR and carbonaceous sorbents, carbonized molecular sieves and pure charcoals; at low nanogram levels for Tenax TA and at 5 ng to 50 ng levels for other porous polymers.

Committee
ISO/TC 146/SC 6
DevelopmentNote
Supersedes ISO/DIS 16017-2. (05/2003)
DocumentType
Standard
Pages
35
PublisherName
International Organization for Standardization
Status
Current

DIN ISO 16000-18:2012-01 Indoor air - Part 18: Detection and enumeration of moulds - Sampling by impaction (ISO 16000-18:2011 + Cor.1:2011)
BS ISO 16000-25:2011 Indoor air Determination of the emission of semi-volatile organic compounds by building products. Micro-chamber method
DIN ISO 16000-6:2012-11 Indoor air - Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA? sorbent, thermal desorption and gas chromatography using MS or MS-FID (ISO 16000-6:2011)
06/30155808 DC : DRAFT SEP 2006 BS EN 13999-4 - ADHESIVES - SHORT-TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES
12/30263496 DC : 0 BS ISO 12219-5 - INTERIOR AIR OF ROAD VEHICLES - PART 5: SCREENING METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - STATIC CHAMBER METHOD
DIN ISO 16000-28:2012-12 Indoor air - Part 28: Determination of odour emissions from building products using test chambers (ISO 16000-28:2012)
BS ISO 16000-16:2008 Indoor air Detection and enumeration of moulds. Sampling by filtration
03/306295 DC : DRAFT APR 2003 EN 14662-4 - AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 4: DIFFUSIVE SAMPLING FOLLOWED BY THERMAL DESORPTION AND GAS CHROMATOGRAPHY
BS ISO 16000-29:2014 Indoor air Test methods for VOC detectors
DIN ISO 12219-3:2013-12 Interior air of road vehicles - Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Micro-scale chamber method (ISO 12219-3:2012)
ISO 16000-13:2008 Indoor air — Part 13: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Collection on sorbent-backed filters
ISO 16000-14:2009 Indoor air — Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry
ISO 16000-25:2011 Indoor air Part 25: Determination of the emission of semi-volatile organic compounds by building products Micro-chamber method
ISO 12219-2:2012 Interior air of road vehicles — Part 2: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials — Bag method
BS EN 13528-3:2003 Ambient air quality. Diffusive samplers for the determination of concentrations of gases and vapours. Requirements and test methods Guide to selection, use and maintenance
BS EN ISO 16000-7:2007 Indoor air Sampling strategy for determination of airborne asbestos fibre concentrations
BS EN 14662-4:2005 Ambient air quality. Standard method for measurement of benzene concentrations Diffusive sampling followed by thermal desorption and gas chromatography
I.S. EN 13999-4:2007 ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES
I.S. EN 838:2010 WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS
EN 13528-3:2003 Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 3: Guide to selection, use and maintenance
DIN ISO 12219-2:2012-11 Interior air of road vehicles - Part 2: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Bag method (ISO 12219-2:2012)
DIN ISO 16000-25:2012-01 Indoor air - Part 25: Determination of the emission of semi-volatile organic compounds by building products - Micro-chamber method (ISO 16000-25:2011)
DIN ISO 16000-3:2013-01 Indoor air - Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air - Active sampling method (ISO 16000-3:2011)
DIN ISO 12219-1:2013-12 Interior air of road vehicles - Part 1: Whole vehicle test chamber - Specification and method for the determination of volatile organic compounds in cabin interiors (ISO 12219-1:2012)
DIN ISO 16000-17:2010-06 Indoor air - Part 17: Detection and enumeration of moulds - Culture-based method (ISO 16000-17:2008)
BS ISO 12219-2:2012 Interior air of road vehicles Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials. Bag method
03/306296 DC : DRAFT APR 2003 EN 14662-5 - AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 5: DIFFUSIVE SAMPLING FOLLOWED BY SOLVENT DESORPTION AND GAS CHROMATOGRAPHY
ISO 16000-4:2011 Indoor air Part 4: Determination of formaldehyde Diffusive sampling method
DIN ISO 16000-13:2010-03 Indoor air - Part 13: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Collection on sorbent-backed filters (ISO 16000-13:2008)
ISO 16000-3:2011 Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method
BS ISO 16000-18:2011 Indoor air Detection and enumeration of moulds. Sampling by impaction
ISO 16000-15:2008 Indoor air — Part 15: Sampling strategy for nitrogen dioxide (NO2)
DIN EN ISO 16000-15:2009-04 INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2])
UNI EN 838 : 2010 WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS
VDI 4300 Blatt 9:2005-08 Measurement of indoor air pollution - Measurement strategy for carbon dioxide (CO)
UNI EN ISO 16000-15 : 2008 INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2])
BS ISO 12219-4:2013 Interior air of road vehicles Method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials. Small chamber method
10/30209057 DC : 0 BS ISO 16000-6 - INDOOR AIR - PART 6: DETERMINATION OF VOLATILE ORGANIC COMPOUNDS IN INDOOR AND TEST CHAMBER AIR BY ACTIVE SAMPLING ON TENAX TA SORBENT, THERMAL DESORPTION AND GAS CHROMATOGRAPHY USING MS/FID
BS ISO 16000-8:2007 Indoor air Determination of local mean ages of air in buildings for characterizing ventilation conditions
BS ISO 12219-3:2012 Interior air of road vehicles Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials. Micro-scale chamber method
ASTM D 7758 : 2017 : REDLINE Standard Practice for Passive Soil Gas Sampling in the Vadose Zone for Source Identification, Spatial Variability Assessment, Monitoring, and Vapor Intrusion Evaluations
08/30172873 DC : DRAFT JULY 2008 BS EN 838 - WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS
BS ISO 12219-5:2014 Interior air of road vehicles Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials. Static chamber method
BS EN ISO 16000-15:2008 Indoor air Sampling strategy for nitrogen dioxide (NO2)
BS ISO 16000-6:2011 Indoor air Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID
BS ISO 16000-17:2008 Indoor air Detection and enumeration of moulds. Culture-based method
I.S. EN 15759-2:2018 CONSERVATION OF CULTURAL HERITAGE - INDOOR CLIMATE - PART 2: VENTILATION MANAGEMENT FOR THE PROTECTION OF CULTURAL HERITAGE BUILDINGS AND COLLECTIONS
ISO 12219-4:2013 Interior air of road vehicles — Part 4: Method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials — Small chamber method
EN 15759-2:2018 Conservation of cultural heritage - Indoor climate - Part 2: Ventilation management for the protection of cultural heritage buildings and collections
ISO 16000-7:2007 Indoor air — Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations
EN ISO 16000-15:2008 Indoor air - Part 15: Sampling strategy for nitrogen dioxide (NO2) (ISO 16000-15:2008)
UNI EN 13999-4 : 2009 ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES
DIN ISO 16000-8:2008-12 INDOOR AIR - PART 8: DETERMINATION OF LOCAL MEAN AGES OF AIR IN BUILDINGS FOR CHARACTERIZING VENTILATION CONDITIONS
BS ISO 12219-1:2012 Indoor air of road vehicles Whole vehicle test chamber. Specification and method for the determination of volatile organic compounds in cabin interiors
BS ISO 16000-28:2012 Indoor air Determination of odour emissions from building products using test chambers
16/30332593 DC : 0 BS EN 15759-2 - CONSERVATION OF CULTURAL HERITAGE - INDOOR CLIMATE - PART 2: VENTILATION TO PROTECT HERITAGE BUILDINGS AND COLLECTIONS
BS ISO 16000-14:2009 Indoor air Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs). Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry
BS ISO 16000-3:2011 Indoor air Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air. Active sampling method
DIN ISO 12219-5:2014-10 INTERIOR AIR OF ROAD VEHICLES - PART 5: SCREENING METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - STATIC CHAMBER METHOD (ISO 12219-5:2014)
DIN ISO 12219-5 E : 2014 INTERIOR AIR OF ROAD VEHICLES - PART 5: SCREENING METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - STATIC CHAMBER METHOD (ISO 12219-5:2014)
ISO 12219-3:2012 Interior air of road vehicles — Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials — Micro-scale chamber method
ISO 12219-1:2012 Interior air of road vehicles Part 1: Whole vehicle test chamber Specification and method for the determination of volatile organic compounds in cabin interiors
ISO 16000-8:2007 Indoor air Part 8: Determination of local mean ages of air in buildings for characterizing ventilation conditions
ISO 16000-28:2012 Indoor air Part 28: Determination of odour emissions from building products using test chambers
ISO 12219-5:2014 Interior air of road vehicles — Part 5: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials — Static chamber method
DIN EN 13999-4:2009-08 ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES
DIN EN 838:2010-05 Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods
ISO 16000-17:2008 Indoor air — Part 17: Detection and enumeration of moulds — Culture-based method
BS EN 13999-4 : 2007 ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES
ISO 16000-18:2011 Indoor air Part 18: Detection and enumeration of moulds Sampling by impaction
BS EN 838:2010 Workplace exposure. Procedures for measuring gases and vapours using diffusive samplers. Requirements and test methods
BS EN ISO 16000-5:2007 Indoor air Sampling strategy for volatile organic compounds (VOCs)
ISO 16000-16:2008 Indoor air — Part 16: Detection and enumeration of moulds — Sampling by filtration
EN 14662-4:2005 Ambient air quality - Standard method for measurement of benzene concentrations - Part 4: Diffusive sampling followed by thermal desorption and gas chromatography
EN ISO 16000-7:2007 Indoor air - Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations (ISO 16000-7:2007)
EN ISO 16000-5:2007 Indoor air - Part 5: Sampling strategy for volatile organic compounds (VOCs) (ISO 16000-5:2007)
EN 838:2010 Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods
EN 13999-4:2007+A1:2009 Adhesives - Short term method for measuring the emission properties of low-solvent or solvent-free adhesives after application - Part 4: Determination of volatile diisocyanates
DIN ISO 16000-29:2015-02 INDOOR AIR - PART 29: TEST METHODS FOR VOC DETECTORS (ISO 16000-29:2014)
DIN ISO 16000-4:2012-11 INDOOR AIR - PART 4: DETERMINATION OF FORMALDEHYDE - DIFFUSIVE SAMPLING METHOD (ISO 16000-4:2011)
I.S. EN ISO 16000-15:2008 INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2])
BS ISO 16000-13:2008 Indoor air Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs). Collection on sorbent-backed filters
DIN ISO 12219-4:2013-12 INTERIOR AIR OF ROAD VEHICLES - PART 4: METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - SMALL CHAMBER METHOD (ISO 12219-4:2013)
DIN ISO 16000-16:2009-12 Indoor air - Part 16: Detection and enumeration of moulds - Sampling by filtration (ISO 16000-16:2008)
BS ISO 16000-4:2011 Indoor air Determination of formaldehyde. Diffusive sampling method
DIN ISO 16000-14:2012-03 Indoor air - Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry (ISO 16000-14:2009)
ISO 16000-6:2011 Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID
I.S. EN ISO 16000-5:2007 INDOOR AIR - PART 5: SAMPLING STRATEGY FOR VOLATILE ORGANIC COMPOUNDS (VOCS)
ISO 16000-29:2014 Indoor air — Part 29: Test methods for VOC detectors
ISO 16000-5:2007 Indoor air Part 5: Sampling strategy for volatile organic compounds (VOCs)
DIN EN 14662-4:2005-08 AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 4: DIFFUSIVE SAMPLING FOLLOWED BY THERMAL DESORPTION AND GAS CHROMATOGRAPHY
DIN EN ISO 16000-7:2007-11 Indoor air - Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations (ISO 16000-7:2007)
DIN EN ISO 16000-5:2007-05 Indoor air - Part 5: Sampling strategy for volatile organic compounds (VOCs) (ISO 16000-5:2007)

VDI 2119 Blatt 4:1997-08 Measurement of Particulate Precipitations - Microscopic differentiation and size fractionated determination of particle deposition on adhesive collection plates - Sigma-2 sampler
EN 838:2010 Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods
EN 482:2012+A1:2015 Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents
EN 13528-1:2002 Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 1: General requirements
EN 13528-2:2002 Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 2: Specific requirements and test methods
ISO 6145-5:2009 Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 5: Capillary calibration devices
ISO 16000-1:2004 Indoor air — Part 1: General aspects of sampling strategy
ISO 6145-4:2004 Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 4: Continuous syringe injection method
ISO 6145-3:1986 Gas analysis Preparation of calibration gas mixtures Dynamic volumetric methods Part 3: Periodic injections into a flowing gas stream
ISO 6145-1:2003 Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 1: Methods of calibration
ISO 6141:2015 Gas analysis Contents of certificates for calibration gas mixtures
ISO 6145-6:2017 Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.